Part Overview

The Phoenix Contact 1094755 is a relay socket designed for DIN rail mounting applications. This component functions as an interface for miniature relays, utilizing spring terminal connections for secure electrical contact. The product is classified as obsolete, necessitating identification of active equivalent components to maintain system functionality and ensure continued availability for replacement and new installations.

Substiute Parts

1094755
Phoenix ContactIn Stock: 8331094755 Datasheet
1094755
Current Part
1094764
Phoenix ContactIn Stock: 10871094764 Datasheet
1094764
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number 1094755
Manufacturer Phoenix Contact
Series PLC-BPT
Product Type Relay Socket
Mounting Type DIN Rail
Termination Style Spring Terminal
For Use With Miniature Relays
Product Status Obsolete
ECCN Classification EAR99
HTSUS Code 8536.90.4000

Substitute Part Grouping Explanation

The substitute part 1094764 is identified as a manufacturer-recommended equivalent based on the following alignment criteria:

Common Substitution Parameters:

  • Manufacturer: Phoenix Contact (same manufacturer ensures design compatibility)
  • Mounting Type: DIN Rail (identical mechanical interface)
  • Termination Style: Spring Terminal (compatible connection method)
  • ECCN Classification: EAR99 (equivalent export control status)
  • Relay Interface: Both components support miniature relay applications

The 1094764 is an active general-purpose relay with integrated socket functionality, providing a consolidated solution where the socket and relay are combined into a single component. This substitution maintains electrical and mechanical compatibility while offering the advantage of active product status and continued manufacturer support.

Parameter Comparison

Parameter 1094755 (Main Part) 1094764 (Substitute)
Manufacturer Phoenix Contact Phoenix Contact
Product Type Relay Socket General Purpose Relay with Socket
Mounting Type DIN Rail DIN Rail
Termination Style Spring Terminal Spring Terminal
Product Status Obsolete Active
ECCN EAR99 EAR99
HTSUS Code 8536.90.4000 8536.41.0020
RoHS Status Not specified ROHS3 Compliant
REACH Status Not specified REACH Affected

Engineering Selection Recommendations

Product Status Consideration: The 1094755 is obsolete and no longer supported by the manufacturer. The 1094764 is an active product with current manufacturer support, ensuring availability of technical documentation, spare parts, and design continuity.

Compliance Status: The 1094764 meets ROHS3 compliance requirements and is REACH-affected, indicating adherence to current environmental and regulatory standards. These certifications support long-term system reliability and regulatory compliance in applications subject to these requirements.

Electrical and Mechanical Compatibility: Both components share identical mounting methodology (DIN rail), termination approach (spring terminal), and manufacturer origin (Phoenix Contact). The 1094764 provides integrated relay functionality with socket capability, eliminating the need for separate socket and relay components in new designs or replacement scenarios.

Frequently Asked Questions (FAQ)

Q: Can the 1094764 directly replace the 1094755 in existing installations?

A: The 1094764 provides equivalent DIN rail mounting and spring terminal connectivity. However, the 1094764 is a complete relay assembly rather than a socket-only component. System integration requires verification that the relay specifications (5VDC coil, SPST-NO contact form, 6A rating) align with the original application requirements.

Q: What is the functional difference between these two components?

A: The 1094755 is a socket interface designed to accept miniature relays. The 1094764 is a complete general-purpose relay with integrated socket functionality. The 1094764 eliminates the need for a separate relay component when used as a replacement.

Q: Are there packaging differences between these parts?

A: The 1094755 packaging is listed as unspecified. The 1094764 is supplied in bulk packaging. Both components are available in new original condition with current inventory levels.

Q: What compliance certifications apply to the substitute part?

A: The 1094764 holds ROHS3 compliance certification and is REACH-affected. These certifications confirm compliance with current environmental regulations and hazardous substance restrictions applicable to electronic components.

Q: How do the HTSUS codes differ between these components?

A: The 1094755 carries HTSUS code 8536.90.4000 (relay parts, other). The 1094764 carries HTSUS code 8536.41.0020 (relays, electromechanical). The difference reflects the functional classification of each component type.

Q: Is the substitute part suitable for new design implementations?

A: Yes. The 1094764 is an active product with current manufacturer support, making it suitable for new installations. The active product status ensures ongoing availability and technical support compared to the obsolete 1094755.

Request Quote (Ships tomorrow)