Request Quote
(Ships tomorrow)
Phoenix Contact 1020080 Circuit Breaker - Equivalent & Substitute Parts
Part Overview
The Phoenix Contact 1020080 is a thermal magnetic circuit breaker rated for 60A with dual voltage capability (277V AC / 125V DC). This DIN rail-mounted device features a lever actuator and is designed for two-pole protection applications. The part is currently active in production with 974 units in stock. Circuit breakers of this specification are essential in industrial control systems where reliable overcurrent and thermal protection is required across multiple voltage standards.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 1020080 |
| Manufacturer | Phoenix Contact |
| Series | TMC 7 |
| Current Rating | 60A |
| Voltage Rating - AC | 277V |
| Voltage Rating - DC | 125V |
| Breaker Type | Thermal Magnetic |
| Mounting Type | DIN Rail |
| Number of Poles | 2 |
| Actuator Type | Lever |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
| REACH Status | REACH Affected |
Substitute Part Grouping Explanation
Substitution eligibility for the Phoenix Contact 1020080 is determined by strict equivalence across the following critical parameters:
- Current Rating: 60A (exact match required)
- Voltage Rating - AC: 277V (exact match required)
- Voltage Rating - DC: 125V (exact match required)
- Breaker Type: Thermal Magnetic (exact match required)
- Mounting Type: DIN Rail (exact match required)
- Number of Poles: 2 (exact match required)
- Actuator Type: Lever (exact match required)
- Series: TMC 7 (exact match required)
Both substitute parts listed below meet all these criteria and are therefore classified as parametric equivalents within the TMC 7 series.
Parameter Comparison
| Parameter | 1020080 (Main) | 1019949 (Substitute) | 1020013 (Substitute) |
|---|---|---|---|
| Manufacturer | Phoenix Contact | Phoenix Contact | Phoenix Contact |
| Series | TMC 7 | TMC 7 | TMC 7 |
| Current Rating | 60A | 60A | 60A |
| Voltage Rating - AC | 277V | 277V | 277V |
| Voltage Rating - DC | 125V | 125V | 125V |
| Breaker Type | Thermal Magnetic | Thermal Magnetic | Thermal Magnetic |
| Mounting Type | DIN Rail | DIN Rail | DIN Rail |
| Number of Poles | 2 | 2 | 2 |
| Actuator Type | Lever | Lever | Lever |
| Product Status | Active | Active | Active |
| Packaging | Box | Box | Box |
| Inventory Status | 974 Pcs In Stock | 1045 Pcs In Stock | 896 Pcs In Stock |
Engineering Selection Recommendations
All three parts—1020080, 1019949, and 1020013—are active production items from Phoenix Contact's TMC 7 series and are direct parametric equivalents. Selection between these parts may be based on the following factors:
Compliance Certifications: Part 1020080 and 1020013 carry ROHS3 Compliant status with REACH Affected designation. Part 1019949 carries RoHS Compliant status. Applications requiring ROHS3 certification should specify either 1020080 or 1020013.
Availability: All three parts maintain adequate inventory levels. Part 1019949 has the highest stock level at 1045 units, followed by 1020080 at 974 units and 1020013 at 896 units.
Regulatory Requirements: Applications subject to REACH regulations should utilize parts 1020080 or 1020013, both marked as REACH Affected.
Frequently Asked Questions (FAQ)
Q: Can Phoenix Contact 1019949 directly replace 1020080 in my application?
A: Part 1019949 is a parametric equivalent to 1020080 across all critical electrical and mechanical specifications: 60A current rating, 277V AC / 125V DC voltage ratings, thermal magnetic protection, DIN rail mounting, two-pole configuration, and lever actuation. However, if your application requires ROHS3 certification or REACH compliance documentation, verify that 1019949's RoHS Compliant status meets your regulatory requirements, as it differs from 1020080's ROHS3 designation.
Q: What is the difference between 1020080 and 1020013?
A: Both parts are parametric equivalents with identical electrical and mechanical specifications. The primary difference is inventory availability: 1020080 has 974 units in stock while 1020013 has 896 units. Both carry ROHS3 Compliant and REACH Affected certifications.
Q: Are all three parts interchangeable in DIN rail installations?
A: Yes. All three parts share identical mounting specifications: DIN rail mounting type, two-pole configuration, and lever actuator design. Physical installation and electrical connection are identical across all three part numbers.
Q: Which part should I select for new designs?
A: For new designs, any of the three parts is acceptable based on parametric equivalence. Selection should prioritize: (1) regulatory compliance requirements (ROHS3 vs. RoHS Compliant), (2) REACH documentation needs, and (3) supplier availability and lead time.
Q: Do these parts require any special handling or storage considerations?
A: All three parts carry Moisture Sensitivity Level (MSL) 1 (Unlimited), indicating no special moisture control requirements during storage or handling.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts