Request Quote
(Ships tomorrow)
Phoenix Contact 1019913 Circuit Breaker 6A Equivalent & Substitute Parts
Part Overview
The Phoenix Contact 1019913 is a thermal magnetic circuit breaker rated for 6A with dual voltage capability (277V AC / 60V DC). This single-pole DIN rail mounted breaker features lever actuation and is part of the TMC 7 series. The product is currently active in production with ROHS3 compliance and REACH affected status. Substitute parts are identified when identical electrical and mechanical parameters are maintained across the TMC 7 series, ensuring direct interchangeability in existing installations.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | Phoenix Contact |
| Series | TMC 7 |
| Current Rating | 6A |
| Voltage Rating - AC | 277V |
| Voltage Rating - DC | 60V |
| Breaker Type | Thermal Magnetic |
| Mounting Type | DIN Rail |
| Number of Poles | 1 |
| Actuator Type | Lever |
| RoHS Status | ROHS3 Compliant |
| MSL Rating | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitute parts for the Phoenix Contact 1019913 are identified based on strict parametric equivalence within the TMC 7 series. The following electrical and mechanical parameters must remain identical for substitution eligibility:
- Current Rating: 6A
- Voltage Rating (AC): 277V
- Voltage Rating (DC): 60V
- Breaker Type: Thermal Magnetic
- Mounting Type: DIN Rail
- Number of Poles: 1
- Actuator Type: Lever
- Series: TMC 7
Parts 1019977 and 1020042 meet all substitution criteria and are direct parametric equivalents to the main part number 1019913.
Parameter Comparison
| Parameter | 1019913 | 1019977 | 1020042 |
|---|---|---|---|
| Manufacturer | Phoenix Contact | Phoenix Contact | Phoenix Contact |
| Series | TMC 7 | TMC 7 | TMC 7 |
| Current Rating (Amps) | 6A | 6A | 6A |
| Voltage Rating - AC | 277V | 277V | 277V |
| Voltage Rating - DC | 60V | 60V | 60V |
| Breaker Type | Thermal Magnetic | Thermal Magnetic | Thermal Magnetic |
| Mounting Type | DIN Rail | DIN Rail | DIN Rail |
| Number of Poles | 1 | 1 | 1 |
| Actuator Type | Lever | Lever | Lever |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
| MSL Rating | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) |
| Product Status | Active | Active | Active |
| Packaging | Box | Box | Box |
Engineering Selection Recommendations
All three part numbers (1019913, 1019977, and 1020042) are active production items with identical electrical and mechanical specifications. Selection between these equivalents may be based on inventory availability and regulatory compliance status:
- Part 1019913: REACH Affected status; 954 units in stock
- Part 1019977: REACH Unaffected status; 995 units in stock
- Part 1020042: REACH Unaffected status; 1025 units in stock
For applications subject to REACH regulations, parts 1019977 or 1020042 are preferred. All parts maintain ROHS3 compliance and identical performance characteristics for thermal magnetic circuit protection at 6A across 277V AC and 60V DC operating ranges.
Frequently Asked Questions (FAQ)
Q: Can part 1019977 or 1020042 be used as a direct replacement for 1019913?
A: Yes. Parts 1019977 and 1020042 are parametric equivalents with identical current rating, voltage ratings, breaker type, mounting configuration, and actuator type. Direct substitution is supported without circuit modification.
Q: What is the difference between these three part numbers?
A: The three parts are electrically and mechanically identical. The primary difference is REACH regulatory status: 1019913 is REACH Affected, while 1019977 and 1020042 are REACH Unaffected. All maintain ROHS3 compliance.
Q: Are there any inventory considerations when selecting between these parts?
A: Current stock levels are 954 units (1019913), 995 units (1019977), and 1025 units (1020042). Selection may depend on procurement lead time and supply chain requirements.
Q: Do these parts require any special handling or storage conditions?
A: All three parts carry MSL Rating 1 (Unlimited), indicating no moisture sensitivity restrictions for storage or handling.
Q: Can these breakers be used in both AC and DC circuits?
A: Yes. All three parts are rated for 277V AC and 60V DC operation, supporting dual-voltage applications within these specified ranges.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts