Littelfuse 0NLS125.X Fuse Cartridge - Equivalent & Substitute Parts

Part Overview

The Littelfuse 0NLS125.X is a 125A fast-blow fuse cartridge rated for 600 VAC/VDC operation, designed for electrical and industrial applications. This component is classified as Class K5 and requires a compatible fuse holder for installation. The part is currently active in production with 1129 units in stock. Substitute parts are identified when equivalent electrical ratings, mechanical dimensions, and approval certifications align with the original specification.

Substiute Parts

0NLS125.X
Littelfuse Inc.In Stock: 11710NLS125.X Datasheet
0NLS125.X
Current Part
NOS-125
Eaton - Bussmann Electrical DivisionIn Stock: 969NOS-125 Datasheet
NOS-125
MFR Recommended

Key Parameters

Parameter Value
Current Rating 125A
Voltage Rating - AC 600 VAC
Voltage Rating - DC 600 VDC
Response Time Fast Blow
Fuse Class K5
Breaking Capacity @ Rated Voltage 50kA
Package / Case Cylindrical, Blade Terminals
Size / Dimension 1.843" Dia x 6.878" L (46.80mm x 174.70mm)
Approval Agencies CE, CSA, UL
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitute parts for the 0NLS125.X are identified based on the following critical parameters that determine functional equivalence:

  • Current Rating: 125A
  • Voltage Rating: 600 VAC / 600 VDC
  • Response Time: Fast Blow
  • Fuse Class: K5
  • Breaking Capacity: 50kA
  • Physical Dimensions: Cylindrical form factor with blade terminals
  • Approval Certifications: CE, CSA, UL compliance

The Eaton - Bussmann Electrical Division NOS-125 meets these electrical and mechanical requirements, establishing it as a qualified substitute within the same application category.

Parameter Comparison

Parameter Littelfuse 0NLS125.X Eaton NOS-125
Manufacturer Littelfuse Inc. Eaton - Bussmann Electrical Division
Current Rating 125A 125A
Voltage Rating - AC 600 VAC 600 VAC
Voltage Rating - DC 600 VDC 600 VDC
Response Time Fast Blow Fast Blow
Fuse Class K5 K5
Breaking Capacity @ Rated Voltage 50kA 50kA
Package / Case Cylindrical, Blade Terminals Cylindrical, Blade Terminals
Product Status Active Active
RoHS Status ROHS3 Compliant RoHS Compliant
ECCN Classification EAR99 EAR99
HTSUS Code 8536.10.0040 8536.10.0040

Engineering Selection Recommendations

Both the Littelfuse 0NLS125.X and Eaton NOS-125 are active production components with equivalent electrical specifications and regulatory compliance. Selection between these parts should be based on:

  • Availability and lead time requirements
  • Inventory status (Littelfuse: 1129 units; Eaton: 893 units in stock)
  • Existing supply chain relationships
  • RoHS compliance requirements (both meet applicable standards)
  • Regulatory certifications required for the application (both carry CE, CSA, UL approvals)

Frequently Asked Questions (FAQ)

Q: Can the Eaton NOS-125 be used as a direct replacement for the Littelfuse 0NLS125.X?

A: Yes. Both parts share identical electrical ratings (125A, 600 VAC/VDC), response characteristics (fast blow), fuse class (K5), and physical form factor (cylindrical with blade terminals). Both carry equivalent regulatory approvals.

Q: Are there any dimensional differences between these fuses?

A: The provided specifications confirm both parts use cylindrical form factor with blade terminals. Verify physical dimensions with the manufacturer datasheet before installation to ensure compatibility with the fuse holder assembly.

Q: What is the significance of the K5 fuse class?

A: Class K5 designates the fuse's performance characteristics, including breaking capacity and response time. Both substitute parts maintain this classification, ensuring equivalent protection performance in the circuit.

Q: Do both parts meet RoHS requirements?

A: Yes. The Littelfuse 0NLS125.X is ROHS3 Compliant, and the Eaton NOS-125 is RoHS Compliant. Both meet current environmental compliance standards.

Q: What is the breaking capacity, and why does it matter?

A: Both parts have a 50kA breaking capacity at rated voltage. This specification defines the maximum fault current the fuse can safely interrupt without rupturing or creating a hazard.

Request Quote (Ships tomorrow)