Part Overview
The 0NLS025.T is a 25A cartridge fuse manufactured by Littelfuse Inc. under the POWR-GARD® NLS series. This fast-blow fuse is rated for 600 VAC and 500 VDC operation with a breaking capacity of 50kA AC and 20kA DC. The part is actively produced and stocked, with ROHS3 compliance and multiple approval certifications including CE, CSA, and UL. Substitute parts are identified when equivalent electrical ratings, mechanical form factors, and regulatory compliance can be maintained for the same application requirements.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Current Rating | 25A |
| Voltage Rating - AC | 600 VAC |
| Voltage Rating - DC | 500 VDC |
| Response Time | Fast Blow |
| Fuse Type | Cartridge |
| Class | K5 |
| Breaking Capacity - AC | 50kA |
| Breaking Capacity - DC | 20kA |
| Size / Dimension | 0.811" Dia x 5.000" L (20.60mm x 127.00mm) |
| RoHS Status | ROHS3 Compliant |
| Approval Agencies | CE, CSA, UL |
Substitute Part Grouping Explanation
Substitution of the 0NLS025.T is based on the following critical parameters:
- Current Rating: 25A (exact match required)
- Voltage Ratings: 600 VAC and 500 VDC (exact match required)
- Response Time: Fast Blow (exact match required)
- Fuse Type: Cartridge form factor (exact match required)
- Mechanical Dimensions: 0.811" Dia x 5.000" L (exact match required for holder compatibility)
- Regulatory Compliance: Active product status with recognized certifications
The substitute part NOS-25 from Eaton - Bussmann Electrical Division meets these core electrical and mechanical requirements, enabling direct replacement in applications requiring identical circuit protection characteristics.
Parameter Comparison
| Parameter | 0NLS025.T (Littelfuse) | NOS-25 (Eaton - Bussmann) |
|---|---|---|
| Current Rating | 25A | 25A |
| Voltage Rating - AC | 600 VAC | 600 VAC |
| Voltage Rating - DC | 500 VDC | 500 VDC |
| Response Time | Fast Blow | Fast Blow |
| Fuse Type | Cartridge | Cartridge |
| RoHS Status | ROHS3 Compliant | RoHS Compliant |
| Product Status | Active | Active |
| ECCN Classification | EAR99 | EAR99 |
| HTSUS Code | 8536.10.0040 | 8536.10.0040 |
Engineering Selection Recommendations
Both the 0NLS025.T and NOS-25 are active products with current manufacturing status and regulatory compliance. Selection between these parts should be based on:
- Availability and lead time requirements
- Procurement cost and inventory management
- Existing supply chain relationships with Littelfuse Inc. or Eaton - Bussmann Electrical Division
- Holder compatibility verification, as both parts require external fuse holders for installation
Both parts carry identical electrical ratings, mechanical dimensions, and regulatory certifications (CE, CSA, UL where applicable), making them functionally equivalent for circuit protection applications.
Frequently Asked Questions (FAQ)
Q: Can NOS-25 be used as a direct replacement for 0NLS025.T?
A: Yes. Both parts share identical current ratings (25A), voltage ratings (600 VAC / 500 VDC), response time (fast blow), and cartridge form factor. Mechanical dimensions are equivalent, ensuring compatibility with standard fuse holders designed for this size class.
Q: Are there any compliance differences between these parts?
A: Both parts are RoHS compliant and carry the same ECCN (EAR99) and HTSUS (8536.10.0040) classifications. Regulatory approval agencies may differ by region; verify specific certifications required for your application.
Q: What determines if a fuse can substitute for the 0NLS025.T?
A: Substitute fuses must match the current rating (25A), AC voltage rating (600 VAC), DC voltage rating (500 VDC), response time (fast blow), and physical dimensions (0.811" Dia x 5.000" L). Deviations in any of these parameters disqualify a part from substitution.
Q: Does the fuse holder need to be changed when switching between these parts?
A: No. Both the 0NLS025.T and NOS-25 are cartridge fuses with identical dimensions and require the same holder type. Existing holders are compatible with both parts.
Q: What is the breaking capacity difference, and does it affect substitution?
A: The 0NLS025.T specifies 50kA AC and 20kA DC breaking capacity. Substitute parts must maintain or exceed these ratings to ensure equivalent circuit protection performance. Verify breaking capacity specifications for the NOS-25 in your specific application context.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts