Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts for 0CNN100E.V
Part Overview
The 0CNN100E.V is a 100A fuse strip designed for bolt mount applications in lift truck systems, rated for 125 VAC and 80 VDC operation. This component is classified as obsolete, making identification of suitable substitute parts essential for maintenance and replacement operations. The fuse provides fast-blow response characteristics with indicating features and is certified to cURus standards with a breaking capacity of 2.5kA at rated voltage.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Current Rating | 100A |
| Voltage Rating - AC | 125 VAC |
| Voltage Rating - DC | 80 VDC |
| Fuse Type | Fuse Strip |
| Mounting Type | Bolt Mount |
| Response Time | Fast Blow |
| Breaking Capacity @ Rated Voltage | 2.5kA |
| Package / Case | Cylindrical, Blade Terminal (Bolt) |
| Approval Agency | cURus |
Substitute Part Grouping Explanation
Substitution eligibility for the 0CNN100E.V is determined by the following critical parameters:
- Current Rating: Must be 100A
- Voltage Rating - DC: Must be 80 VDC minimum
- Fuse Type: Must be Fuse Strip
- Mounting Type: Must be Bolt Mount
- Response Time: Must be Fast Blow
- Package / Case: Must be Cylindrical, Blade Terminal (Bolt)
- Approval Agency: Must maintain cURus certification
The 0CNN100E.HXU meets all substitution criteria. While the AC voltage rating differs (0CNN100E.HXU is DC-only), the DC rating of 80 VDC is maintained, and the component shares identical current rating, fuse type, mounting configuration, response characteristics, and approval standards. The 0CNN100E.HXU represents an active product status alternative with enhanced breaking capacity (3kA vs. 2.5kA).
Parameter Comparison
| Parameter | 0CNN100E.V (Main Part) | 0CNN100E.HXU (Substitute) |
|---|---|---|
| Manufacturer | Littelfuse Inc. | Littelfuse Inc. |
| Current Rating (Amps) | 100A | 100A |
| Voltage Rating - AC | 125 VAC | Not Rated |
| Voltage Rating - DC | 80 VDC | 80 VDC |
| Fuse Type | Fuse Strip | Fuse Strip |
| Mounting Type | Bolt Mount | Bolt Mount |
| Response Time | Fast Blow | Fast Blow |
| Breaking Capacity @ Rated Voltage | 2.5kA | 3kA |
| Package / Case | Cylindrical, Blade Terminal (Bolt) | Cylindrical, Blade Terminal (Bolt) |
| Approval Agency | cURus | cURus |
| Product Status | Obsolete | Active |
| Series | POWR-GARD® CNN_E | POWR-GARD® CNN_E-U |
Engineering Selection Recommendations
The 0CNN100E.HXU is the manufacturer-recommended substitute for the obsolete 0CNN100E.V. Both components maintain identical electrical specifications for DC operation at 80 VDC and 100A current rating, with matching fuse strip configuration and bolt mount packaging. The substitute part carries active product status, ensuring continued availability and supply chain reliability. The increased breaking capacity of 3kA in the 0CNN100E.HXU provides enhanced fault protection compared to the original 2.5kA specification. Both parts retain cURus certification, maintaining compliance with applicable standards. Selection of the 0CNN100E.HXU is appropriate for direct replacement in DC-only applications; however, applications requiring AC voltage capability at 125 VAC should be evaluated for alternative solutions outside this substitute group.
Frequently Asked Questions (FAQ)
Q: Can the 0CNN100E.HXU replace the 0CNN100E.V in all applications?
A: The 0CNN100E.HXU is suitable for replacement in applications operating at 80 VDC with 100A current requirements. If the original application requires 125 VAC operation, the substitute part is not appropriate, as it is rated for DC operation only.
Q: What is the difference in breaking capacity between these parts?
A: The 0CNN100E.V has a breaking capacity of 2.5kA at rated voltage, while the 0CNN100E.HXU provides 3kA. The higher breaking capacity of the substitute part offers improved fault protection without affecting normal operation.
Q: Are both parts mechanically compatible?
A: Yes. Both the 0CNN100E.V and 0CNN100E.HXU use identical cylindrical blade terminal bolt mount packaging, ensuring mechanical compatibility in existing installations.
Q: Why is the original part obsolete?
A: The 0CNN100E.V is classified as obsolete by the manufacturer. The 0CNN100E.HXU represents the active product line continuation within the POWR-GARD® CNN_E series, with improved specifications and ongoing availability.
Q: Are both parts certified to the same standards?
A: Yes. Both components carry cURus approval certification, maintaining compliance with applicable regulatory requirements.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts