Request Quote
(Ships tomorrow)
HARTING 09661557513 D-Sub 9 Position Receptacle Equivalent & Substitute Parts
Part Overview
The HARTING 09661557513 is a 9 position D-Sub receptacle connector with female sockets, designed for through-hole solder termination. This connector features a vertical mounting orientation, mating-side female screwlock (4-40), and board lock functionality. The part is currently active in production with 1060 units in stock.
Equivalent and substitute parts are necessary when the primary part becomes unavailable, when alternative packaging or mounting configurations are required for specific application layouts, or when design revisions necessitate connector variants with different flange features or shell finishes.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Connector Type | D-Sub Receptacle, Female Sockets |
| Number of Positions | 9 |
| Number of Rows | 2 |
| Shell Size / Layout | 1 (DE, E) |
| Mounting Type | Through Hole |
| Termination | Solder |
| Current Rating | 6.5A |
| Operating Temperature | -55°C ~ 125°C |
| Material Flammability Rating | UL94 V-0 |
| RoHS Status | ROHS3 Compliant |
| Contact Finish | Gold |
| Shell Material | Steel |
| Flange Feature | Mating Side, Female Screwlock (4-40) |
| Features | Board Lock |
Substitute Part Grouping Explanation
Substitution eligibility for the HARTING 09661557513 is determined by the following critical parameters:
Core Compatibility Requirements:
- Connector type: D-Sub receptacle with female sockets
- Position count: 9 positions in 2-row configuration
- Shell size: 1 (DE, E) layout
- Termination method: Solder
- Mounting: Through-hole capability
Performance Compatibility:
- Current rating: Minimum 6.5A (substitute parts rated 5A or higher are acceptable for most applications, though 6.5A rating is preferred)
- Operating temperature range: Minimum -55°C to 125°C coverage
- Material flammability: UL94 V-0 compliance required
Mechanical Compatibility:
- Flange feature variations: Mating-side screwlock, board-side screwlock, or unthreaded housing are functionally equivalent depending on application mounting requirements
- Shell finish: Steel with various plating options (tin, nickel) are mechanically compatible
- Contact material: Copper alloy, brass, or phosphor bronze are electrically equivalent
Regulatory Compliance:
- RoHS3 compliance preferred for new designs
- REACH compliance status noted for supply chain considerations
Substitute parts meeting these criteria are grouped by mounting configuration and flange feature, as these determine physical fit in specific application layouts.
Parameter Comparison
| Parameter | HARTING 09661557513 | 172-009-212R021 | 172-E09-213R001 | 172-E09-213R011 | 172-E09-213R021 | 172-E09-213R911 | 191-009-213L571 | 2-747706-0 | 207826-4 | 4-338313-2 | 5207826-3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Manufacturer | HARTING | NorComp Inc. | NorComp Inc. | NorComp Inc. | NorComp Inc. | NorComp Inc. | NorComp Inc. | TE Connectivity | TE Connectivity | TE Connectivity | TE Connectivity |
| Connector Type | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets | Receptacle, Female Sockets |
| Number of Positions | 9 | 9 | 9 | 9 | 9 | 9 | 9 | 9 | 9 | 9 | 9 |
| Number of Rows | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Shell Size / Layout | 1 (DE, E) | 1 (DE, E) | 1 (DE, E) | 1 (DE, E) | 1 (DE, E) | 1 (DE, E) | 1 (DE, E) | 1 (DE, E) | 1 (DE, E) | 1 (DE, E) | 1 (DE, E) |
| Mounting Type | Through Hole | Panel Mount, Through Hole | Panel Mount, Through Hole | Panel Mount, Through Hole | Panel Mount, Through Hole | Panel Mount, Through Hole | Panel Mount, Through Hole | Through Hole | Through Hole | Through Hole | Through Hole |
| Termination | Solder | Solder | Solder | Solder | Solder | Solder | Solder | Solder | Solder | Solder | Solder |
| Current Rating (Amps) | 6.5A | 5A | 5A | 5A | 5A | 5A | 5A | 6A | 6A | 6A | 6A |
| Operating Temperature | -55°C ~ 125°C | -50°C ~ 100°C | -50°C ~ 100°C | -50°C ~ 100°C | -50°C ~ 100°C | -50°C ~ 100°C | -55°C ~ 125°C | -55°C ~ 105°C | -55°C ~ 105°C | -55°C ~ 105°C | -55°C ~ 105°C |
| Material Flammability Rating | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 | UL94 V-0 |
| Contact Finish | Gold | Gold | Gold | Gold | Gold | Gold | Gold | Gold | Gold | Gold | Gold |
| Shell Material Finish | Steel | Steel, Tin Plated | Steel, Nickel Plated | Steel, Nickel Plated | Steel, Nickel Plated | Steel, Nickel Plated | Steel, Nickel Plated | Steel, Tin Plated | Not Specified | Steel, Tin Plated | Not Specified |
| Flange Feature | Mating Side, Female Screwlock (4-40) | Board Side (4-40) | Housing/Shell (Unthreaded) | Board Side (4-40) | Board Side (4-40) | Board Side (4-40), Mating Side, Female Screwlock (4-40) | Mating Side, Female Screwlock (4-40) | Housing/Shell (4-40) | Housing/Shell (Unthreaded) | Mating Side, Female Screwlock (M3) | Housing/Shell (Unthreaded) |
| Features | Board Lock | None | None | None | None | Board Lock | Board Lock, Shielded | Board Lock | None | Board Lock | None |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | RoHS non-compliant | RoHS non-compliant | RoHS Compliant | RoHS Compliant |
| Product Status | Active | Obsolete | Active | Active | Active | Active | Active | Active | Active | Active | Active |
Engineering Selection Recommendations
Primary Substitutes (Highest Compatibility):
172-E09-213R911 (NorComp Inc.) is the closest functional equivalent. It maintains the mating-side female screwlock (4-40) flange feature and board lock functionality identical to the HARTING 09661557513. Both parts are active products with ROHS3 compliance. The primary difference is the operating temperature range (-50°C to 100°C versus -55°C to 125°C), which is acceptable for applications not requiring the full extended temperature range.
191-009-213L571 (NorComp Inc.) provides an alternative with identical operating temperature range (-55°C to 125°C) and mating-side screwlock configuration. This part adds shielding and is active with ROHS3 compliance. The board lock feature is retained.
Secondary Substitutes (Panel Mount Variants):
172-E09-213R001, 172-E09-213R011, and 172-E09-213R021 (NorComp Inc.) are panel mount variants suitable for applications requiring panel-mounted receptacles. All three are active products with ROHS3 compliance. 172-E09-213R011 and 172-E09-213R021 feature board-side screwlock (4-40), while 172-E09-213R001 uses unthreaded housing. These parts operate at -50°C to 100°C.
TE Connectivity Alternatives:
2-747706-0, 4-338313-2, and 5207826-3 (TE Connectivity AMPLIMITE HD-20 series) are through-hole vertical mount options. 4-338313-2 and 5207826-3 are RoHS compliant and active. 2-747706-0 is RoHS non-compliant. All three feature board lock functionality. Operating temperature is -55°C to 105°C. Current rating is 6A, which is acceptable for the 6.5A requirement.
Compliance Considerations:
For new designs requiring RoHS3 compliance, avoid 2-747706-0 and 207826-4 (both RoHS non-compliant). NorComp 172-E series and 191-009-213L571 are preferred for RoHS3 applications. TE Connectivity 4-338313-2 and 5207826-3 are RoHS compliant alternatives.
172-009-212R021 (NorComp) is obsolete and should not be selected for new designs despite ROHS3 compliance.
Frequently Asked Questions (FAQ)
Q: Can I substitute a panel mount variant for the vertical through-hole HARTING 09661557513?
A: Panel mount variants (172-E09 series) have different mechanical mounting configurations and are not direct substitutes for vertical through-hole applications. Panel mount connectors are designed for mounting on the edge of a PCB with the connector body extending perpendicular to the board surface. The HARTING 09661557513 is a vertical through-hole mount designed for standard PCB mounting. Use panel mount variants only if your application specifically requires panel-edge mounting.
Q: What is the significance of the flange feature differences (mating-side screwlock vs. board-side screwlock vs. unthreaded)?
A: The flange feature determines how the connector is secured to the mating connector or cable assembly. Mating-side female screwlock (4-40) means the receptacle has threaded holes on the mating face for securing the plug connector with screws. Board-side screwlock (4-40) means the threaded holes are on the board-facing side. Unthreaded housing has no threaded mounting points. These are not interchangeable without modifying the mating connector or cable assembly design.
Q: The HARTING part has a 6.5A current rating, but some substitutes are rated 5A. Is this acceptable?
A: Current rating indicates the maximum continuous current the connector can safely carry. A 5A-rated substitute is acceptable only if your application's actual current draw is 5A or less. If your design requires the full 6.5A capacity, select substitutes rated 6A or higher (TE Connectivity AMPLIMITE HD-20 series parts are rated 6A).
Q: Why do some substitutes have different operating temperature ranges?
A: Operating temperature range is determined by the dielectric material and contact material used in the connector. The HARTING 09661557513 operates from -55°C to 125°C. NorComp 172-E series parts operate from -50°C to 100°C due to different dielectric materials (Polyamide PA6T versus Polycyclohexylenedimethylene Terephthalate). Select substitutes based on your application's actual temperature requirements. If your application operates within -50°C to 100°C, the NorComp parts are suitable. If extended temperature range is required, use 191-009-213L571 or TE Connectivity parts.
Q: What does "Board Lock" feature mean?
A: Board lock is a mechanical feature that prevents the connector from being accidentally pulled out of the PCB during mating or unmating operations. It provides additional mechanical retention beyond the solder joints. The HARTING 09661557513 includes board lock. Most recommended substitutes (172-E09-213R911, 191-009-213L571, 2-747706-0, 4-338313-2) also include this feature. If board lock is critical to your application, avoid 172-E09-213R001, 172-E09-213R021, 207826-4, and 5207826-3.
Q: Are there packaging differences I should consider?
A: The HARTING 09661557513 is supplied in bulk packaging. Substitutes are available in bulk, tray, or tube packaging. Packaging affects handling, storage, and automated assembly compatibility. Verify that your assembly process can accommodate the packaging format of your selected substitute.
Q: What is the difference between RoHS3 compliant and RoHS non-compliant parts?
A: RoHS3 compliance means the part meets Restriction of Hazardous Substances Directive requirements, restricting the use of lead, mercury, cadmium, and other hazardous materials. RoHS non-compliant parts (2-747706-0, 207826-4) may contain these substances and are restricted in certain markets and applications. For new designs, select RoHS3 compliant substitutes unless legacy system compatibility requires non-compliant parts.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts