Request Quote
(Ships tomorrow)
HARTING 09651626813 D-Sub Connector: Equivalent & Substitute Parts
Part Overview
The HARTING 09651626813 is a 9-position D-Sub plug connector with right-angle solder termination, designed for through-hole mounting applications. This connector features male pins, a DE/E shell size, and mating-side female screwlock fastening. The part is currently active in production with 1168 units in stock inventory. Equivalent and substitute parts are identified to support procurement flexibility, design revisions, and supply chain continuity when the primary part becomes unavailable or when alternative specifications better suit specific application requirements.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Connector Type | Plug, Male Pins |
| Number of Positions | 9 |
| Shell Size, Connector Layout | 1 (DE, E) |
| Mounting Type | Through Hole, Right Angle |
| Termination | Solder |
| Operating Temperature Range | -55°C ~ 125°C |
| Current Rating | 5A minimum |
| Connector Style | D-Sub |
Substitute Part Grouping Explanation
Substitution of the HARTING 09651626813 with the TE Connectivity 1218440-1 is based on alignment of the following critical parameters:
- Connector Type & Configuration: Both parts are 9-position D-Sub plugs with male pins and DE/E shell size
- Mounting & Termination: Both feature through-hole, right-angle mounting with solder termination
- Operating Temperature: Both rated for -55°C to 125°C operation
- Current Capacity: The substitute part (5A) meets the minimum current requirement for applications designed for the primary part (6.5A)
- Connector Style: Both are D-Sub connectors suitable for identical mating receptacles
The TE Connectivity 1218440-1 is qualified as a direct substitute based on these functional and electrical equivalencies. Differences in shell finish, contact material, and compliance certifications are noted in the parameter comparison and must be evaluated against specific application requirements.
Parameter Comparison
| Parameter | HARTING 09651626813 | TE Connectivity 1218440-1 |
|---|---|---|
| Manufacturer Part Number | 09651626813 | 1218440-1 |
| Manufacturer | HARTING | TE Connectivity Aerospace, Defense and Marine |
| Connector Type | Plug, Male Pins | Plug, Male Pins |
| Number of Positions | 9 | 9 |
| Shell Size, Connector Layout | 1 (DE, E) | 1 (DE, E) |
| Mounting Type | Through Hole, Right Angle | Through Hole, Right Angle |
| Termination | Solder | Solder |
| Shell Material, Finish | Steel | Steel, Cadmium Plated |
| Contact Material | Copper Alloy | Brass |
| Contact Finish | Not specified | Gold, 10.0µin (0.25µm) |
| Current Rating (Amps) | 6.5A | 5A |
| Operating Temperature | -55°C ~ 125°C | -55°C ~ 125°C |
| Backset Spacing | 0.409" (10.40mm) | 0.318" (8.08mm) |
| Flange Feature | Mating Side, Female Screwlock (4-40) | Housing/Shell (Unthreaded) |
| Product Status | Active | Active |
| RoHS Status | ROHS3 Compliant | RoHS non-compliant |
| Dielectric Material | Polybutylene Terephthalate (PBT), Polyester, Glass Filled | Not specified |
| Material Flammability Rating | UL94 V-0 | Not specified |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Affected |
Engineering Selection Recommendations
Primary Part Selection: The HARTING 09651626813 is recommended for new designs and applications requiring RoHS3 compliance, UL94 V-0 flammability certification, and REACH unaffected status. This part is actively produced with adequate inventory availability.
Substitute Part Selection: The TE Connectivity 1218440-1 is qualified as a substitute for applications where the following conditions are met:
- Current requirements do not exceed 5A
- RoHS non-compliance is acceptable for the application
- REACH-affected materials are permissible
- Cadmium-plated steel shell and gold-plated brass contacts are compatible with the operating environment
- Backset spacing difference (0.318" vs. 0.409") does not conflict with PCB layout constraints
- Unthreaded housing is compatible with the mating receptacle design
Both parts maintain identical operating temperature ranges (-55°C to 125°C) and connector geometry (9-position DE/E D-Sub plug with right-angle solder termination). Selection between these parts depends on compliance requirements, current capacity needs, and environmental specifications of the target application.
Frequently Asked Questions (FAQ)
Q: Can the TE Connectivity 1218440-1 be used as a direct replacement for the HARTING 09651626813 in all applications?
A: The TE Connectivity 1218440-1 is functionally equivalent for connector mating and electrical signal transmission. However, substitution requires verification that the application tolerates the 5A current rating (versus 6.5A), accepts RoHS non-compliance, and is compatible with cadmium plating and gold contact finishes. Backset spacing differences must also be evaluated against PCB layout requirements.
Q: What is the significance of the backset spacing difference (0.409" vs. 0.318")?
A: Backset spacing defines the distance from the mating face to the solder tail termination points. The HARTING part has a longer backset (0.409"), while the TE Connectivity substitute has a shorter backset (0.318"). This difference affects PCB footprint design and component placement. Designs must accommodate the specific backset of the selected part.
Q: Are there compliance or certification differences between these parts?
A: Yes. The HARTING 09651626813 is ROHS3 compliant with UL94 V-0 flammability rating and REACH unaffected status. The TE Connectivity 1218440-1 is RoHS non-compliant and REACH affected. Applications subject to RoHS or REACH regulations must use the HARTING part or verify regulatory exemptions.
Q: What is the difference between the flange features?
A: The HARTING part features a mating-side female screwlock (4-40) for threaded fastening to the mating receptacle. The TE Connectivity substitute has an unthreaded housing/shell. The mating receptacle design must be compatible with the selected flange configuration.
Q: Do both parts have the same contact material and finish?
A: No. The HARTING part uses copper alloy contacts with unspecified finish. The TE Connectivity substitute uses brass contacts with 10.0µin (0.25µm) gold plating. Gold plating provides enhanced corrosion resistance and contact reliability in certain environments but may not be necessary for all applications.
Q: What is the current rating difference, and does it matter?
A: The HARTING part is rated for 6.5A, while the TE Connectivity substitute is rated for 5A. For applications requiring current levels between 5A and 6.5A, the HARTING part must be used. For applications operating at or below 5A, both parts are suitable.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts