Part Overview
The 09032966862 is a 96-position DIN 41612 connector receptacle manufactured by HARTING, designed for through-hole PCB mounting applications. This component features female sockets with gold plating and is classified as an active product. The connector accommodates high-density interconnections in industrial and telecommunications equipment where reliable signal transmission and mechanical stability are required. Equivalent substitute parts may be necessary due to inventory availability, lead time considerations, or specific application requirements within the allowed electrical and mechanical parameter ranges.
Substiute Parts
Key Parameters
| Parameter | Specification |
|---|---|
| Manufacturer Part Number | 09032966862 |
| Manufacturer | HARTING |
| Category | Backplane Connectors |
| Connector Type | Receptacle, Female Sockets |
| Number of Positions | 96 |
| Pitch | 0.100" (2.54mm) |
| Number of Rows | 3 |
| Style | C |
| Mounting Type | Through Hole |
| Termination | Press-Fit |
| Contact Finish | Gold |
| Operating Temperature Range | -40°C to 105°C |
| Material Flammability Rating | UL94 V-0 |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level | 1 (Unlimited) |
| Product Status | Active |
Substitute Part Grouping Explanation
Substitution eligibility for the 09032966862 is determined by strict adherence to the following critical parameters:
- Connector Configuration: 96-position receptacle with female sockets, 3-row arrangement, DIN 41612 Style C
- Electrical Interface: 0.100" (2.54mm) pitch, press-fit termination, gold contact finish
- Mechanical Mounting: Through-hole PCB mounting
- Environmental Compliance: UL94 V-0 flammability rating, MSL 1 classification
- Regulatory Status: RoHS compliance and ECCN EAR99 classification
The substitute part 86093968194755E3LF meets all critical substitution criteria within these defined parameters. Both parts share identical position count, pitch, row configuration, mounting method, and contact finish specifications. Differences in operating temperature range, current rating, and insulation material composition do not preclude substitution when the application requirements fall within the substitute part's specifications.
Parameter Comparison
| Parameter | 09032966862 (HARTING) | 86093968194755E3LF (Amphenol ICC/FCI) | Compatibility |
|---|---|---|---|
| Number of Positions | 96 | 96 | Identical |
| Connector Type | Receptacle, Female Sockets | Receptacle, Female Sockets | Identical |
| Pitch | 0.100" (2.54mm) | 0.100" (2.54mm) | Identical |
| Number of Rows | 3 | 3 | Identical |
| Style | C | C | Identical |
| Mounting Type | Through Hole | Through Hole | Identical |
| Termination | Press-Fit | Press-Fit | Identical |
| Contact Finish | Gold | Gold | Identical |
| Material Flammability Rating | UL94 V-0 | UL94 V-0 | Identical |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) | Identical |
| Operating Temperature Range | -40°C to 105°C | -55°C to 125°C | Substitute has extended range |
| Current Rating | Not specified | 1.5A | Substitute specifies rating |
| RoHS Status | ROHS3 Compliant | RoHS Compliant | Both compliant |
| Product Status | Active | Active | Both active |
Engineering Selection Recommendations
Both the 09032966862 and 86093968194755E3LF are active products with current manufacturing status and full regulatory compliance. Selection between these parts should be based on application-specific requirements:
The 09032966862 (HARTING) operates within the -40°C to 105°C temperature range and carries ROHS3 compliance certification. The 86093968194755E3LF (Amphenol ICC/FCI) provides an extended operating temperature range of -55°C to 125°C with RoHS compliance and specifies a 1.5A current rating per contact. Both connectors meet UL94 V-0 flammability requirements and maintain MSL 1 moisture sensitivity classification.
For applications requiring operation at temperatures below -40°C or above 105°C, the Amphenol ICC/FCI substitute provides extended thermal performance. For applications operating within the HARTING part's specified temperature envelope, either connector is suitable based on availability and procurement lead times. Both parts are mechanically and electrically interchangeable within their respective operating specifications.
Frequently Asked Questions (FAQ)
Q: Can the 86093968194755E3LF directly replace the 09032966862 in existing designs?
A: Yes, within the operating temperature range of -40°C to 105°C. Both connectors share identical mechanical dimensions, pitch, position count, mounting method, and contact configuration. The substitute part's extended temperature range (-55°C to 125°C) does not affect compatibility in applications operating within the original part's specifications.
Q: What are the key parameters that determine substitution eligibility?
A: Substitution is valid when the following parameters match: 96-position count, 0.100" pitch, 3-row configuration, Style C DIN 41612 format, receptacle with female sockets, through-hole mounting, press-fit termination, and gold contact finish. Both parts meet these criteria.
Q: Does the difference in packaging (Bulk vs. Tray) affect electrical or mechanical performance?
A: No. Packaging format affects only handling, storage, and logistics. The electrical and mechanical characteristics of the connector remain identical regardless of packaging type.
Q: Are there compliance differences between the two parts?
A: Both parts meet UL94 V-0 flammability and MSL 1 moisture sensitivity requirements. The HARTING part carries ROHS3 certification, while the Amphenol ICC/FCI part carries RoHS certification. Both are compliant with their respective regulatory frameworks and ECCN EAR99 classification.
Q: What is the significance of the 1.5A current rating specified for the substitute part?
A: The 86093968194755E3LF specifies a 1.5A per-contact current rating. The 09032966862 does not provide this specification in the available data. Applications requiring current-carrying capacity confirmation should reference the 1.5A rating of the substitute part or contact the HARTING manufacturer for the original part's current rating specification.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts