Molex 0395432003 Terminal Block: Equivalent & Substitute Parts
Part Overview
The Molex 0395432003 is a 3-position wire-to-board terminal block with 5.00mm pitch, designed for horizontal mounting on PCBs through screw-leaf spring termination. This component is classified as Active and maintains full RoHS3 compliance. Equivalent and substitute parts are identified based on matching electrical ratings, mechanical compatibility, and functional performance within the Eurostyle ESE 39543 series and compatible alternatives.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 0395432003 |
| Manufacturer | Molex |
| Category | Terminal Blocks |
| Series | Eurostyle ESE 39543 |
| Positions Per Level | 3 |
| Pitch | 0.197" (5.00mm) |
| Mating Orientation | Horizontal with Board |
| Current Rating | 10 A |
| Voltage Rating | 300 V |
| Wire Gauge | 14-24 AWG |
| Mounting Type | Through Hole |
| Wire Termination | Screw - Leaf Spring, Wire Guard |
| Operating Temperature | -40°C ~ 105°C |
| Housing Material | Polyamide (PA66), Nylon 6/6 |
| RoHS Status | ROHS3 Compliant |
| Product Status | Active |
Substitute Part Grouping Explanation
Substitution eligibility for the Molex 0395432003 is determined by the following critical parameters:
- Electrical Compatibility: Voltage rating (300 V minimum), current capacity (10 A minimum), and wire gauge acceptance (14-24 AWG minimum range)
- Mechanical Compatibility: 3-position configuration, through-hole mounting, horizontal board orientation, and pitch tolerance within 5.00mm ± 0.08mm
- Termination Method: Screw-based wire termination with equivalent clamping force and wire retention
- Environmental Compliance: RoHS3 compliance and operating temperature range support
The identified substitute parts meet these criteria while maintaining functional equivalence for wire-to-board connection applications.
Parameter Comparison
| Parameter | Molex 0395432003 | Phoenix Contact 1985933 | Phoenix Contact 1985959 |
|---|---|---|---|
| Manufacturer Part Number | 0395432003 | 1985933 | 1985959 |
| Manufacturer | Molex | Phoenix Contact | Phoenix Contact |
| Category | Terminal Blocks | Terminal Blocks | Terminal Blocks |
| Series | Eurostyle ESE 39543 | COMBICON MKDSN | COMBICON MKDSN |
| Positions Per Level | 3 | 3 | 3 |
| Pitch | 0.197" (5.00mm) | 0.197" (5.00mm) | 0.200" (5.08mm) |
| Mating Orientation | Horizontal with Board | Horizontal with Board | Horizontal with Board |
| Current Rating | 10 A | 20 A | 20 A |
| Voltage Rating | 300 V | 300 V | 300 V |
| Wire Gauge | 14-24 AWG | 12-30 AWG | 12-30 AWG |
| Mounting Type | Through Hole | Through Hole | Through Hole |
| Wire Termination | Screw - Leaf Spring, Wire Guard | Screw - Rising Cage Clamp | Screw - Rising Cage Clamp |
| Housing Material | Polyamide (PA66), Nylon 6/6 | Polyamide (PA), Nylon | Polyamide (PA), Nylon |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
| Product Status | Active | Active | Active |
Engineering Selection Recommendations
Phoenix Contact 1985933 qualifies as a direct substitute based on matching pitch (5.00mm), voltage (300 V), position count (3), and through-hole mounting configuration. This part exceeds the current rating requirement (20 A vs. 10 A) and expands wire gauge acceptance (12-30 AWG vs. 14-24 AWG). Both parts maintain RoHS3 compliance and Active product status. The termination method differs (rising cage clamp vs. leaf spring), but both employ screw-based wire retention.
Phoenix Contact 1985959 provides substitution with a pitch variance of 0.08mm (5.08mm vs. 5.00mm). This tolerance may require PCB layout verification for through-hole alignment. Current and voltage ratings match the 1985933 specification. RoHS3 compliance and Active status are maintained. Pitch deviation necessitates mechanical compatibility assessment before deployment.
Both Phoenix Contact alternatives are suitable for applications where the Molex 0395432003 is unavailable, provided that PCB footprint and mechanical constraints accommodate the specified pitch and termination geometry.
Frequently Asked Questions (FAQ)
Q: Can Phoenix Contact 1985933 replace Molex 0395432003 in existing designs?
A: Yes. Both parts share identical pitch (5.00mm), voltage rating (300 V), position count (3), and through-hole mounting. The Phoenix Contact part accepts a wider wire gauge range (12-30 AWG) and provides higher current capacity (20 A). Termination method differs (rising cage clamp vs. leaf spring), but both employ screw-based clamping. No PCB redesign is required.
Q: What is the pitch difference between Molex 0395432003 and Phoenix Contact 1985959?
A: Phoenix Contact 1985959 has a pitch of 5.08mm compared to the Molex part's 5.00mm pitch. This 0.08mm difference may affect through-hole alignment on existing PCBs. Mechanical compatibility must be verified before substitution.
Q: Are all three parts RoHS3 compliant?
A: Yes. Molex 0395432003, Phoenix Contact 1985933, and Phoenix Contact 1985959 are all RoHS3 compliant and maintain Active product status.
Q: What wire gauges are supported by each part?
A: Molex 0395432003 supports 14-24 AWG. Both Phoenix Contact alternatives (1985933 and 1985959) support 12-30 AWG, providing broader wire gauge compatibility.
Q: Do the substitute parts have different current ratings?
A: Yes. Molex 0395432003 is rated for 10 A, while both Phoenix Contact alternatives are rated for 20 A. The higher rating of the substitutes does not prevent their use in 10 A applications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts