Littelfuse 0325003.MXP Ceramic Fuse - Equivalent & Substitute Parts

Part Overview

The Littelfuse 0325003.MXP is a 3 A ceramic cartridge fuse rated for 250 V AC and 125 V DC operation. This through-hole component is designed for applications requiring slow-blow response characteristics and is housed in a 3AB/3AG form factor measuring 0.275" diameter by 1.288" length. The part maintains Active product status with full compliance to international safety standards including UL, CSA, CE, K-MARK, and PSE certifications. Identifying equivalent substitute parts ensures design flexibility, supply chain continuity, and component availability across manufacturing cycles.

Substiute Parts

0325003.MXP
Littelfuse Inc.In Stock: 11590325003.MXP Datasheet
0325003.MXP
Current Part
0325003.HXP
Littelfuse Inc.In Stock: 12150325003.HXP Datasheet
0325003.HXP
Parametric Equivalent

Key Parameters

Parameter Value
Current Rating 3 A
Voltage Rating - AC 250 V
Voltage Rating - DC 125 V
Fuse Type Cartridge, Ceramic
Response Time Slow Blow
Package / Case 3AB, 3AG, 1/4" x 1-1/4" (Axial)
Breaking Capacity @ Rated Voltage 100A AC, 10kA DC
Mounting Type Through Hole
Operating Temperature Range -55°C ~ 125°C
DC Cold Resistance 0.0605 Ohms

Substitute Part Grouping Explanation

Substitution of the Littelfuse 0325003.MXP is determined by strict equivalence across the following critical parameters:

  • Current Rating: 3 A (exact match required)
  • Voltage Rating - AC: 250 V (exact match required)
  • Voltage Rating - DC: 125 V (exact match required)
  • Fuse Type: Cartridge, Ceramic (exact match required)
  • Response Time: Slow Blow (exact match required)
  • Package / Case: 3AB, 3AG, 1/4" x 1-1/4" (Axial) (exact match required)
  • Breaking Capacity @ Rated Voltage: 100A AC, 10kA DC (exact match required)
  • Melting I²t: 200 (exact match required)

The substitute part 0325003.HXP from Littelfuse Inc. meets all these criteria and is classified as a parametric equivalent. Both parts are manufactured by the same supplier, belong to the same 325 series, and maintain identical electrical and mechanical specifications.

Parameter Comparison

Parameter 0325003.MXP (Main Part) 0325003.HXP (Substitute) Match Status
Manufacturer Littelfuse Inc. Littelfuse Inc. Identical
Series 325 325 Identical
Current Rating (Amps) 3 A 3 A Identical
Voltage Rating - AC 250 V 250 V Identical
Voltage Rating - DC 125 V 125 V Identical
Fuse Type Cartridge, Ceramic Cartridge, Ceramic Identical
Response Time Slow Blow Slow Blow Identical
Package / Case 3AB, 3AG, 1/4" x 1-1/4" (Axial) 3AB, 3AG, 1/4" x 1-1/4" (Axial) Identical
Breaking Capacity @ Rated Voltage 100A AC, 10kA DC 100A AC, 10kA DC Identical
Melting I²t 200 200 Identical
Mounting Type Through Hole Through Hole Identical
Operating Temperature -55°C ~ 125°C -55°C ~ 125°C Identical
DC Cold Resistance 0.0605 Ohms 0.0605 Ohms Identical
Product Status Active Active Identical
Approval Agency CE, CSA, K-MARK, PSE, UL CE, CSA, K-MARK, PSE, UL Identical
RoHS Status ROHS3 Compliant ROHS3 Compliant Identical
REACH Status REACH Unaffected REACH Unaffected Identical

Engineering Selection Recommendations

Both the Littelfuse 0325003.MXP and 0325003.HXP maintain Active product status and carry identical international safety certifications (UL, CSA, CE, K-MARK, PSE). Both components are ROHS3 compliant and REACH unaffected, meeting current environmental and regulatory requirements. The parts are interchangeable from an electrical, mechanical, and compliance perspective. Selection between these two part numbers may be based on inventory availability, lead time, or supply chain logistics, as no technical differentiation exists between them.

Frequently Asked Questions (FAQ)

Q: Can 0325003.HXP be used as a direct replacement for 0325003.MXP in existing designs?

A: Yes. Both parts are parametric equivalents with identical electrical ratings (3 A, 250 V AC, 125 V DC), identical response characteristics (Slow Blow), identical mechanical packaging (3AB/3AG, 0.275" Dia x 1.288" L), and identical breaking capacity (100A AC, 10kA DC). No circuit redesign or board layout modification is required.

Q: Are there any differences in approval certifications between these parts?

A: No. Both parts carry identical certifications: CE, CSA, K-MARK, PSE, and UL. Both are ROHS3 compliant and REACH unaffected.

Q: What determines whether a fuse can substitute for the 0325003.MXP?

A: Substitution requires exact matching of current rating (3 A), AC voltage rating (250 V), DC voltage rating (125 V), fuse type (Cartridge, Ceramic), response time (Slow Blow), package form factor (3AB/3AG, 1/4" x 1-1/4"), breaking capacity (100A AC, 10kA DC), and melting I²t value (200). Deviation in any of these parameters disqualifies a part from substitution.

Q: Can this fuse be used in both AC and DC circuits?

A: Yes. The 0325003.MXP and 0325003.HXP are rated for both AC and DC operation with separate voltage ratings: 250 V AC and 125 V DC. The application circuit must not exceed these respective voltage limits.

Q: What is the significance of the Slow Blow response time?

A: Slow Blow fuses tolerate temporary inrush currents without nuisance blowing, making them suitable for circuits with transient current spikes. This characteristic is identical between both parts and must be maintained in any substitution.

Request Quote (Ships tomorrow)