Littelfuse 0325002.H Ceramic Fuse - Equivalent & Substitute Parts

Part Overview

The Littelfuse 0325002.H is a 2 A, 250 V AC ceramic cartridge fuse in the 3AB/3AG package format (1/4" x 1-1/4" axial). This component is classified as obsolete, making equivalent substitute parts necessary for ongoing circuit protection applications. The fuse provides slow-blow response characteristics with a 100 A breaking capacity at rated voltage and is approved by CSA and UL standards.

Substiute Parts

0325002.H
LittelfuseIn Stock: 9830325002.H Datasheet
0325002.H
Current Part
0325002.HXP
Littelfuse Inc.In Stock: 11600325002.HXP Datasheet
0325002.HXP
Direct
0325002.MXP
Littelfuse Inc.In Stock: 10220325002.MXP Datasheet
0325002.MXP
Parametric Equivalent
0325002.VXP
Littelfuse Inc.In Stock: 7560325002.VXP Datasheet
0325002.VXP
Parametric Equivalent

Key Parameters

Parameter Value
Current Rating 2 A
Voltage Rating - AC 250 V
Fuse Type Cartridge, Ceramic
Response Time Slow Blow
Package / Case 3AB, 3AG, 1/4" x 1-1/4" (Axial)
Mounting Type Through Hole
Breaking Capacity @ Rated Voltage 100 A
Melting I²t 80
Size / Dimension 0.275" Dia x 1.288" L (6.99mm x 32.72mm)
DC Cold Resistance 0.12 Ohms

Substitute Part Grouping Explanation

Substitute parts for the 0325002.H are qualified based on the following critical parameters:

  • Current Rating: 2 A (exact match required)
  • Voltage Rating - AC: 250 V (exact match required)
  • Package / Case: 3AB, 3AG, 1/4" x 1-1/4" (Axial) (exact match required)
  • Fuse Type: Cartridge, Ceramic (exact match required)
  • Response Time: Slow Blow (exact match required)
  • Mounting Type: Through Hole (exact match required)
  • Melting I²t: 80 (exact match required)

The substitute parts listed below meet all these criteria. Additionally, the substitute parts provide enhanced DC voltage rating (125 V DC) and improved compliance status compared to the obsolete main part.

Parameter Comparison

Parameter 0325002.H (Main) 0325002.HXP 0325002.MXP 0325002.VXP
Current Rating (Amps) 2 A 2 A 2 A 2 A
Voltage Rating - AC 250 V 250 V 250 V 250 V
Voltage Rating - DC Not specified 125 V 125 V 125 V
Fuse Type Cartridge, Ceramic Cartridge, Ceramic Cartridge, Ceramic Cartridge, Ceramic
Response Time Slow Blow Slow Blow Slow Blow Slow Blow
Package / Case 3AB, 3AG, 1/4" x 1-1/4" (Axial) 3AB, 3AG, 1/4" x 1-1/4" (Axial) 3AB, 3AG, 1/4" x 1-1/4" (Axial) 3AB, 3AG, 1/4" x 1-1/4" (Axial)
Mounting Type Through Hole Through Hole Through Hole Through Hole
Breaking Capacity @ Rated Voltage 100 A 100 A AC, 10 kA DC 100 A AC, 10 kA DC 100 A AC, 10 kA DC
Melting I²t 80 80 80 80
Size / Dimension 0.275" Dia x 1.288" L (6.99mm x 32.72mm) 0.275" Dia x 1.288" L (6.99mm x 32.72mm) 0.275" Dia x 1.288" L (6.99mm x 32.72mm) 0.275" Dia x 1.288" L (6.99mm x 32.72mm)
DC Cold Resistance 0.12 Ohms 0.121 Ohms 0.121 Ohms 0.121 Ohms
Product Status Obsolete Active Active Active
RoHS Status RoHS non-compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
Approval Agency CSA, UL CE, CSA, PSE, UL CE, CSA, PSE, UL CE, CSA, PSE, UL
Operating Temperature Not specified -55°C ~ 125°C -55°C ~ 125°C -55°C ~ 125°C

Engineering Selection Recommendations

All three substitute parts (0325002.HXP, 0325002.MXP, 0325002.VXP) are direct functional equivalents to the 0325002.H for AC 250 V applications. The substitute parts offer the following advantages:

  • Active product status ensures long-term availability and supply chain continuity
  • ROHS3 compliance meets current environmental and regulatory requirements
  • Extended approval certifications (CE, CSA, PSE, UL) provide broader market acceptance
  • Specified DC voltage rating (125 V) and operating temperature range (-55°C ~ 125°C) enable broader application flexibility
  • Enhanced DC breaking capacity (10 kA) provides superior performance in mixed AC/DC circuits

Selection among the three substitute parts should be based on packaging requirements and inventory availability, as all three are electrically and mechanically identical.

Frequently Asked Questions (FAQ)

Q: Can 0325002.HXP, 0325002.MXP, or 0325002.VXP be used as direct replacements for 0325002.H?

A: Yes. All three substitute parts meet the critical electrical and mechanical parameters of the 0325002.H: 2 A current rating, 250 V AC voltage rating, slow-blow response, 3AB/3AG package format, and 80 melting I²t. The substitute parts are pin-compatible and functionally equivalent for AC 250 V circuit protection applications.

Q: What is the difference between 0325002.HXP, 0325002.MXP, and 0325002.VXP?

A: These three parts are parametrically identical. Differences exist only in packaging designation and inventory source. All three are active products with identical electrical specifications, certifications, and performance characteristics.

Q: Why do the substitute parts specify a 125 V DC rating when the original part does not?

A: The 0325002.H does not specify a DC voltage rating. The substitute parts provide explicit DC voltage rating (125 V) and enhanced DC breaking capacity (10 kA), enabling their use in mixed AC/DC applications. For AC-only applications, this additional specification does not affect compatibility.

Q: Are the substitute parts RoHS compliant?

A: Yes. All three substitute parts (0325002.HXP, 0325002.MXP, 0325002.VXP) are ROHS3 compliant, whereas the original 0325002.H is RoHS non-compliant. This compliance improvement is beneficial for applications subject to environmental regulations.

Q: What certifications do the substitute parts carry?

A: The substitute parts carry CE, CSA, PSE, and UL approvals, compared to CSA and UL for the original part. This expanded certification portfolio supports broader geographic and market applications.

Q: Are there any mechanical differences between the main part and substitute parts?

A: No. All parts share identical dimensions (0.275" Dia x 1.288" L / 6.99mm x 32.72mm), package format (3AB, 3AG, 1/4" x 1-1/4" axial), and mounting type (through hole). Physical interchangeability is complete.

Request Quote (Ships tomorrow)