Littelfuse 0224002.VXP Glass Cartridge Fuse 2A 250VAC 125VDC 2AG Equivalent & Substitute Parts

Part Overview

The Littelfuse 0224002.VXP is a 2A fast-blow glass cartridge fuse rated for 250V AC and 125V DC operation in a 2AG form factor. This through-hole mounted component is designed for circuit protection in industrial and commercial applications. The part maintains active product status with full regulatory compliance across CE, CSA, PSE, and UL certifications. Equivalent substitute parts are available to support procurement flexibility, inventory management, and supply chain continuity.

Substiute Parts

0224002.VXP
Littelfuse Inc.In Stock: 9120224002.VXP Datasheet
0224002.VXP
Current Part
0224002.HXP
Littelfuse Inc.In Stock: 10630224002.HXP Datasheet
0224002.HXP
Parametric Equivalent
0224002.MXP
Littelfuse Inc.In Stock: 19140224002.MXP Datasheet
0224002.MXP
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number 0224002.VXP
Manufacturer Littelfuse Inc.
Current Rating 2 A
Voltage Rating - AC 250 V
Voltage Rating - DC 125 V
Fuse Type Cartridge, Glass
Response Time Fast Blow
Package / Case 2AG, 5mm x 15mm (Axial)
Mounting Type Through Hole
Breaking Capacity @ Rated Voltage 100A AC, 10kA DC
Melting I²t 1.5
Operating Temperature Range -55°C ~ 125°C
DC Cold Resistance 0.0497 Ohms
Approval Agencies CE, CSA, PSE, UL
RoHS Status ROHS3 Compliant
REACH Status REACH Unaffected
Product Status Active

Substitute Part Grouping Explanation

Substitute parts for the 0224002.VXP are determined by electrical and mechanical parameter equivalence. All substitute parts must match the following critical parameters:

  • Current Rating: 2 A
  • Voltage Rating - AC: 250 V
  • Voltage Rating - DC: 125 V
  • Fuse Type: Cartridge, Glass
  • Response Time: Fast Blow
  • Package / Case: 2AG, 5mm x 15mm (Axial)
  • Mounting Type: Through Hole
  • Breaking Capacity @ Rated Voltage: 100A AC, 10kA DC
  • Melting I²t: 1.5
  • Operating Temperature Range: -55°C ~ 125°C
  • DC Cold Resistance: 0.0497 Ohms
  • Approval Agencies: CE, CSA, PSE, UL
  • RoHS Status: ROHS3 Compliant

The substitute parts 0224002.HXP and 0224002.MXP are parametric equivalents manufactured by Littelfuse Inc. under the same 224 series. These parts are interchangeable for direct replacement in applications requiring identical electrical performance and physical form factor.

Parameter Comparison

Parameter 0224002.VXP 0224002.HXP 0224002.MXP
Manufacturer Littelfuse Inc. Littelfuse Inc. Littelfuse Inc.
Current Rating (Amps) 2 A 2 A 2 A
Voltage Rating - AC 250 V 250 V 250 V
Voltage Rating - DC 125 V 125 V 125 V
Fuse Type Cartridge, Glass Cartridge, Glass Cartridge, Glass
Response Time Fast Blow Fast Blow Fast Blow
Package / Case 2AG, 5mm x 15mm (Axial) 2AG, 5mm x 15mm (Axial) 2AG, 5mm x 15mm (Axial)
Mounting Type Through Hole Through Hole Through Hole
Breaking Capacity @ Rated Voltage 100A AC, 10kA DC 100A AC, 10kA DC 100A AC, 10kA DC
Melting I²t 1.5 1.5 1.5
Operating Temperature Range -55°C ~ 125°C -55°C ~ 125°C -55°C ~ 125°C
DC Cold Resistance 0.0497 Ohms 0.0497 Ohms 0.0497 Ohms
Approval Agencies CE, CSA, PSE, UL CE, CSA, PSE, UL CE, CSA, PSE, UL
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected REACH Unaffected
Product Status Active Active Active

Engineering Selection Recommendations

All three parts—0224002.VXP, 0224002.HXP, and 0224002.MXP—are active products with identical electrical and mechanical specifications. Selection between these equivalents may be based on inventory availability and procurement lead times. All parts carry full regulatory compliance with CE, CSA, PSE, and UL certifications, and all meet ROHS3 and REACH requirements. Direct substitution is permissible in any application where the 0224002.VXP is specified.

Frequently Asked Questions (FAQ)

Q: Can 0224002.HXP and 0224002.MXP be used as direct replacements for 0224002.VXP?

A: Yes. All three parts are parametric equivalents with identical current ratings, voltage ratings, fuse type, response time, package form factor, breaking capacity, and thermal characteristics. Direct substitution is permissible without circuit redesign or application modification.

Q: Are there any differences in regulatory compliance between these substitute parts?

A: No. All three parts carry identical certifications: CE, CSA, PSE, and UL. All are ROHS3 compliant and REACH unaffected.

Q: What determines whether a part can substitute for the 0224002.VXP?

A: Substitution is determined by equivalence in current rating (2A), AC voltage rating (250V), DC voltage rating (125V), fuse type (cartridge glass), response time (fast blow), package form factor (2AG, 5mm x 15mm), mounting type (through hole), breaking capacity (100A AC, 10kA DC), melting I²t (1.5), operating temperature range (-55°C to 125°C), and DC cold resistance (0.0497 Ohms).

Q: Can these parts be used in both AC and DC circuits?

A: Yes. All three parts are rated for both AC operation at 250V and DC operation at 125V, making them suitable for dual-voltage applications within these specified limits.

Q: Are there any inventory considerations when selecting between these equivalents?

A: Inventory levels vary: 0224002.VXP has 821 units, 0224002.HXP has 975 units, and 0224002.MXP has 1830 units in stock. Selection may be influenced by procurement requirements and delivery schedules.

Request Quote (Ships tomorrow)