Littelfuse 0219.250MXABP Glass Cartridge Fuse Equivalent & Substitute Parts

Part Overview

The Littelfuse 0219.250MXABP is a 250 mA, 250 V AC/DC slow-blow glass cartridge fuse in 5mm x 20mm form factor. This fuse is designed for circuit protection in applications requiring slow-blow response characteristics and is rated for 150A breaking capacity at rated voltage. The part is active in production with full compliance to international standards including UL, CE, CSA, VDE, CCC, and SEMKO certifications. Equivalent and substitute parts are identified based on matching electrical ratings, mechanical dimensions, response time characteristics, and approval agency compliance to ensure direct interchangeability in circuit protection applications.

Substiute Parts

0219.250MXABP
Littelfuse Inc.In Stock: 10040219.250MXABP Datasheet
0219.250MXABP
Current Part
0218.250HXP
Littelfuse Inc.In Stock: 18110218.250HXP Datasheet
0218.250HXP
Parametric Equivalent
0218.250MXP
Littelfuse Inc.In Stock: 22100218.250MXP Datasheet
0218.250MXP
Parametric Equivalent
0218.250TXP
Littelfuse Inc.In Stock: 13030218.250TXP Datasheet
0218.250TXP
Parametric Equivalent
0219.250MXAP
Littelfuse Inc.In Stock: 64220219.250MXAP Datasheet
0219.250MXAP
Parametric Equivalent
0239.250HXP
Littelfuse Inc.In Stock: 9800239.250HXP Datasheet
0239.250HXP
Parametric Equivalent
0239.250MXP
Littelfuse Inc.In Stock: 19940239.250MXP Datasheet
0239.250MXP
Parametric Equivalent
0618.250MXP
Littelfuse Inc.In Stock: 18280618.250MXP Datasheet
0618.250MXP
Parametric Equivalent
0034.3111
SCHURTER Inc.In Stock: 22210034.3111 Datasheet
0034.3111
Parametric Equivalent
0034.5611.11
SCHURTER Inc.In Stock: 11580034.5611.11 Datasheet
0034.5611.11
Parametric Equivalent
TSC-250MA
OptiFuseIn Stock: 3758TSC-250MA Datasheet
TSC-250MA
Parametric Equivalent
TSD-250MA
OptiFuseIn Stock: 4648TSD-250MA Datasheet
TSD-250MA
Parametric Equivalent

Key Parameters

Parameter Value
Current Rating 250 mA
Voltage Rating (AC) 250 V
Package / Case 5mm x 20mm
Fuse Type Cartridge, Glass
Response Time Slow Blow
Mounting Type Requires Holder
Operating Temperature Range -55°C to 125°C
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the 0219.250MXABP is determined by the following criteria:

Primary Matching Parameters:

  • Current Rating: 250 mA (exact match required)
  • Voltage Rating: 250 V AC (exact match required)
  • Package Dimensions: 5mm x 20mm (exact match required)
  • Fuse Type: Cartridge, Glass (exact match required)
  • Response Time: Slow Blow (exact match required)
  • Mounting Type: Requires Holder (exact match required)

Secondary Compatibility Factors:

  • Operating Temperature Range: -55°C to 125°C (must support or exceed)
  • RoHS Compliance: ROHS3 Compliant (required for environmental compliance)
  • Approval Agencies: Must include UL, CE, or CSA certification

Substitute parts are grouped into two categories based on breaking capacity and melting I²t characteristics:

Category A (High Breaking Capacity): Parts with 150A breaking capacity and 0.54 melting I²t (0219.250MXAP)

Category B (Standard Breaking Capacity): Parts with 35A breaking capacity and melting I²t values between 0.238 and 0.5405 (0218.250HXP, 0218.250MXP, 0218.250TXP, 0239.250HXP, 0239.250MXP, 0618.250MXP, 0034.3111, 0034.5611.11, TSC-250MA)

Category C (Alternative Melting Characteristics): Parts with 35A breaking capacity and lower melting I²t of 0.34 (0239.250HXP, 0239.250MXP)

Parameter Comparison

Part Number Manufacturer Series Current Rating Voltage Rating (AC) Package Response Time Breaking Capacity @ Rated Voltage Melting I²t DC Cold Resistance (Ohms) Approval Agencies Inventory Status
0219.250MXABP Littelfuse Inc. 219XA 250 mA 250 V 5mm x 20mm Slow Blow 150A 0.54 1.0495 CCC, CE, CSA, SEMKO, UL, VDE 940 Pcs
0219.250MXAP Littelfuse Inc. 219XA 250 mA 250 V 5mm x 20mm Slow Blow 150A 0.54 1.0495 CCC, CE, CSA, SEMKO, UL, VDE 6331 Pcs
0218.250HXP Littelfuse Inc. 218 250 mA 250 V 5mm x 20mm Slow Blow 35A 0.5405 1.0495 CCC, CE, CSA, K-MARK, SEMKO, UL, VDE 1775 Pcs
0218.250MXP Littelfuse Inc. 218 250 mA 250 V 5mm x 20mm Slow Blow 35A 0.5405 1.0495 CCC, CE, CSA, K-MARK, SEMKO, UL, VDE 2100 Pcs
0218.250TXP Littelfuse Inc. 218 250 mA 250 V 5mm x 20mm Slow Blow 35A 0.5405 1.0495 CCC, CE, CSA, KC, SEMKO, UL, VDE 1226 Pcs
0239.250HXP Littelfuse Inc. 239 250 mA 250 V 5mm x 20mm Slow Blow 35A 0.34 3.07 CE, CSA, KC, UL 951 Pcs
0239.250MXP Littelfuse Inc. 239 250 mA 250 V 5mm x 20mm Slow Blow 35A 0.34 3.07 CE, CSA, KC, UL 1968 Pcs
0618.250MXP Littelfuse Inc. 618 250 mA 250 V 5mm x 20mm Slow Blow 35A 0.5405 1.0495 CCC, CE, CSA, UR, VDE 1780 Pcs
0034.3111 SCHURTER Inc. FST 5x20 250 mA 250 V 5mm x 20mm Slow Blow 35A 0.238 Not Specified CCC, cURus, VDE 2161 Pcs
0034.5611.11 SCHURTER Inc. SMD-FST 250 mA 250 V 5mm x 20mm Slow Blow 35A 0.238 Not Specified cURus, VDE 1112 Pcs
TSC-250MA OptiFuse TSC 250 mA 250 V 5mm x 20mm Slow Blow 100A 0.278 Not Specified cULus, UL 248 3656 Pcs

Engineering Selection Recommendations

Direct Equivalent (Preferred): The 0219.250MXAP from Littelfuse Inc. (Series 219XA) is the direct equivalent to the 0219.250MXABP. Both parts share identical electrical ratings (250 mA, 250 V), mechanical dimensions (5mm x 20mm), response characteristics (slow blow), breaking capacity (150A), and melting I²t (0.54). Both maintain full compliance with CCC, CE, CSA, SEMKO, UL, and VDE certifications. This part is preferred for applications requiring the same breaking capacity specification.

Littelfuse Series 218 Alternatives (0218.250HXP, 0218.250MXP, 0218.250TXP): These parts maintain identical electrical ratings, dimensions, and response time but feature reduced breaking capacity (35A versus 150A) and slightly higher melting I²t (0.5405 versus 0.54). All three variants retain full compliance with CCC, CE, CSA, SEMKO, UL, and VDE certifications. Selection among these three is based on series preference and availability.

Littelfuse Series 239 Alternatives (0239.250HXP, 0239.250MXP): These parts match electrical ratings and dimensions but feature lower breaking capacity (35A) and significantly lower melting I²t (0.34). DC cold resistance is elevated at 3.07 Ohms compared to 1.0495 Ohms in the main part. Certification coverage is reduced to CE, CSA, KC, and UL. These parts are suitable for applications where lower melting I²t is acceptable and reduced certification scope is permissible.

Littelfuse Series 618 Alternative (0618.250MXP): This part provides identical electrical ratings and dimensions with 35A breaking capacity and 0.5405 melting I²t. Certifications include CCC, CE, CSA, UR, and VDE. This option is suitable when Series 618 is specified in design documentation.

SCHURTER Alternatives (0034.3111, 0034.5611.11): Both SCHURTER parts match electrical ratings and dimensions with 35A breaking capacity and 0.238 melting I²t. Certification coverage is limited to CCC/cURus and VDE. These parts are suitable for applications where SCHURTER brand specification is required or where lower melting I²t is acceptable.

OptiFuse Alternative (TSC-250MA): This part matches electrical ratings and dimensions with 100A breaking capacity and 0.278 melting I²t. Certifications include cULus and UL 248. This option is suitable for applications where OptiFuse brand specification is required or where intermediate breaking capacity is needed.

Frequently Asked Questions (FAQ)

Q: Can I substitute the 0219.250MXABP with any of the listed alternatives?

A: Substitution depends on your application's breaking capacity requirement. The 0219.250MXAP is a direct equivalent with identical 150A breaking capacity. Series 218, 239, 618 alternatives, and SCHURTER/OptiFuse parts feature 35A or 100A breaking capacity and should only be used if your circuit design permits lower breaking capacity ratings.

Q: What is the significance of breaking capacity in fuse selection?

A: Breaking capacity specifies the maximum fault current the fuse can safely interrupt without rupturing the fuse holder or creating a hazard. The main part (0219.250MXABP) is rated for 150A breaking capacity. Lower-rated alternatives (35A or 100A) must only be used in circuits where maximum fault current does not exceed their respective ratings.

Q: How does melting I²t affect fuse performance?

A: Melting I²t is a thermal characteristic that determines the fuse's response to overcurrent. Lower melting I²t values result in faster thermal response. The main part has 0.54 melting I²t. Alternatives with lower values (0.238 to 0.34) will respond more quickly to overcurrent conditions. Selection should align with circuit protection requirements.

Q: Are all substitute parts RoHS3 compliant?

A: Yes, all listed substitute parts are ROHS3 compliant, matching the environmental compliance status of the main part.

Q: What certification differences exist among the alternatives?

A: The main part (0219.250MXABP) includes CCC, CE, CSA, SEMKO, UL, and VDE certifications. Littelfuse Series 218 parts add K-MARK certification. Series 239 parts are limited to CE, CSA, KC, and UL. SCHURTER parts include CCC/cURus and VDE. OptiFuse includes cULus and UL 248. Verify that substitute part certifications meet your regional and application requirements.

Q: Can I use the 0239.250HXP or 0239.250MXP as direct replacements?

A: These parts are mechanically and electrically compatible but feature different DC cold resistance (3.07 Ohms versus 1.0495 Ohms) and lower melting I²t (0.34 versus 0.54). They are suitable only if your circuit design accommodates these thermal and resistance characteristics and if the reduced certification scope (no SEMKO or CCC) is acceptable.

Q: What is the difference between 0034.3111 and 0034.5611.11?

A: Both SCHURTER parts share identical electrical ratings, dimensions, breaking capacity, and melting I²t. The primary difference is series designation (FST 5x20 versus SMD-FST). Selection between these parts depends on design specification or availability preference.

Q: Is the TSC-250MA from OptiFuse a suitable alternative?

A: The TSC-250MA matches electrical ratings and dimensions with 100A breaking capacity and 0.278 melting I²t. It is suitable if OptiFuse brand specification is required or if your circuit design permits 100A breaking capacity. Certification is limited to cULus and UL 248, which may not meet all regional requirements.

Request Quote (Ships tomorrow)