Equivalent & Substitute Parts for 0219002.MXABP

Part Overview

The 0219002.MXABP is a 2 A, 250 V AC/DC glass cartridge fuse manufactured by Littelfuse Inc., designed for applications requiring slow-blow response characteristics in a 5mm x 20mm form factor. This fuse is part of the 219XA series and maintains active product status with full compliance to international safety standards including UL, CE, CSA, and VDE certifications. Equivalent and substitute parts are identified based on matching electrical ratings, mechanical dimensions, and functional response characteristics to ensure seamless integration in circuit protection applications.

Substiute Parts

0219002.MXABP
Littelfuse Inc.In Stock: 19890219002.MXABP Datasheet
0219002.MXABP
Current Part
0213002.MXP
Littelfuse Inc.In Stock: 180180213002.MXP Datasheet
0213002.MXP
Parametric Equivalent
0213002.TXP
Littelfuse Inc.In Stock: 11600213002.TXP Datasheet
0213002.TXP
Parametric Equivalent
0218002.MXP
Littelfuse Inc.In Stock: 96420218002.MXP Datasheet
0218002.MXP
Parametric Equivalent
0218002.TXP
Littelfuse Inc.In Stock: 10460218002.TXP Datasheet
0218002.TXP
Parametric Equivalent
0219002.MXAP
Littelfuse Inc.In Stock: 12320219002.MXAP Datasheet
0219002.MXAP
Parametric Equivalent
0239002.HXP
Littelfuse Inc.In Stock: 24940239002.HXP Datasheet
0239002.HXP
Parametric Equivalent
0239002.MXP
Littelfuse Inc.In Stock: 16310239002.MXP Datasheet
0239002.MXP
Parametric Equivalent
0239002.TXP
Littelfuse Inc.In Stock: 7310239002.TXP Datasheet
0239002.TXP
Parametric Equivalent
0239002.VXP
Littelfuse Inc.In Stock: 9520239002.VXP Datasheet
0239002.VXP
Parametric Equivalent
0618002.MXP
Littelfuse Inc.In Stock: 16870618002.MXP Datasheet
0618002.MXP
Parametric Equivalent
0034.2519
SCHURTER Inc.In Stock: 36890034.2519 Datasheet
0034.2519
Direct
0034.3120
SCHURTER Inc.In Stock: 120750034.3120 Datasheet
0034.3120
Parametric Equivalent
0034.5620.11
SCHURTER Inc.In Stock: 36470034.5620.11 Datasheet
0034.5620.11
Parametric Equivalent
0034.5716.11
SCHURTER Inc.In Stock: 12340034.5716.11 Datasheet
0034.5716.11
Parametric Equivalent
TSC-2A
OptiFuseIn Stock: 1701TSC-2A Datasheet
TSC-2A
Parametric Equivalent
TSD-2A
OptiFuseIn Stock: 14294TSD-2A Datasheet
TSD-2A
Parametric Equivalent

Key Parameters

Parameter Value
Current Rating 2 A
Voltage Rating (AC) 250 V
Fuse Type Cartridge, Glass
Response Time Slow Blow
Package / Case 5mm x 20mm
Mounting Type Requires Holder
Operating Temperature Range -55°C to 125°C
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitute parts for the 0219002.MXABP are classified based on strict electrical and mechanical compatibility. All identified substitutes share the following core parameters with the main part:

  • Current Rating: 2 A
  • Voltage Rating (AC): 250 V
  • Fuse Type: Cartridge, Glass
  • Response Time: Slow Blow
  • Package / Case: 5mm x 20mm
  • Mounting Type: Requires Holder
  • Operating Temperature Range: -55°C to 125°C
  • RoHS Status: ROHS3 Compliant

Substitutes are grouped into two categories based on Breaking Capacity at Rated Voltage:

Category 1 (Breaking Capacity 150 A): 0219002.MXAP Category 2 (Breaking Capacity 100 A): 0239002.HXP, 0239002.MXP, 0239002.TXP, 0239002.VXP Category 3 (Breaking Capacity 35 A): 0213002.MXP, 0213002.TXP, 0218002.MXP, 0218002.TXP, 0618002.MXP

Parameter Comparison

Part Number Manufacturer Series Current Rating (A) Voltage Rating (V AC) Response Time Breaking Capacity (A) Melting I²t DC Cold Resistance (Ω) Inventory (Pcs)
0219002.MXABP Littelfuse Inc. 219XA 2 250 Slow Blow 150 92.705 0.0452 1970
0219002.MXAP Littelfuse Inc. 219XA 2 250 Slow Blow 150 92.705 0.0452 1160
0239002.HXP Littelfuse Inc. 239 2 250 Slow Blow 100 50.585 0.0943 2400
0239002.MXP Littelfuse Inc. 239 2 250 Slow Blow 100 50.585 0.0943 1610
0239002.TXP Littelfuse Inc. 239 2 250 Slow Blow 100 50.585 0.0943 719
0239002.VXP Littelfuse Inc. 239 2 250 Slow Blow 100 50.585 0.0943 931
0213002.MXP Littelfuse Inc. 213 2 250 Slow Blow 35 92.705 0.0452 17911
0213002.TXP Littelfuse Inc. 213 2 250 Slow Blow 35 92.705 0.0452 1142
0218002.MXP Littelfuse Inc. 218 2 250 Slow Blow 35 14.45 0.0293 9616
0218002.TXP Littelfuse Inc. 218 2 250 Slow Blow 35 14.45 0.0293 1032
0618002.MXP Littelfuse Inc. 618 2 250 Slow Blow 35 14.45 0.0293 1607

Engineering Selection Recommendations

Selection of substitute parts must account for Breaking Capacity and Melting I²t characteristics, which determine circuit protection performance under fault conditions.

Direct Equivalent (Highest Compatibility): 0219002.MXAP is the primary equivalent, sharing identical Breaking Capacity (150 A), Melting I²t (92.705), and DC Cold Resistance (0.0452 Ω) with the main part. Both are part of the 219XA series and carry identical approval certifications (CCC, CE, CSA, PSE, SEMKO, UL, VDE).

Alternative Substitutes with Lower Breaking Capacity: Parts from the 239 series (0239002.HXP, 0239002.MXP, 0239002.TXP, 0239002.VXP) provide Breaking Capacity of 100 A with reduced Melting I²t (50.585). These are suitable for applications where lower fault current interruption is acceptable. Approval certifications are limited to CE, CSA, KC, PSE, UL.

Parts from the 213, 218, and 618 series provide Breaking Capacity of 35 A. The 213 series maintains Melting I²t of 92.705 and DC Cold Resistance of 0.0452 Ω. The 218 and 618 series feature reduced Melting I²t (14.45) and DC Cold Resistance (0.0293 Ω), indicating faster response characteristics. These are suitable only for applications with lower fault current requirements.

Frequently Asked Questions (FAQ)

Q: Can 0219002.MXAP be used as a direct replacement for 0219002.MXABP? A: Yes. Both parts share identical electrical ratings (2 A, 250 V AC), response time (Slow Blow), Breaking Capacity (150 A), Melting I²t (92.705), and DC Cold Resistance (0.0452 Ω). Both are ROHS3 compliant and carry the same approval certifications.

Q: What is the difference between parts with 150 A, 100 A, and 35 A Breaking Capacity? A: Breaking Capacity defines the maximum fault current the fuse can safely interrupt without rupturing the fuse body. Higher Breaking Capacity is required in circuits with higher available fault current. Selection must match the circuit's fault current rating.

Q: Can 0239002 series parts replace 0219002.MXABP? A: 0239002 series parts are compatible in terms of current rating, voltage, and physical dimensions. However, they have lower Breaking Capacity (100 A vs. 150 A) and different Melting I²t (50.585 vs. 92.705). Use only if the application's fault current does not exceed 100 A and faster response is acceptable.

Q: What is the significance of Melting I²t? A: Melting I²t indicates the thermal energy required to melt the fuse element. Lower values result in faster response to overcurrent. The main part (92.705) and 213 series (92.705) have identical Melting I²t, while 239 series (50.585) and 218/618 series (14.45) respond faster.

Q: Are all substitute parts ROHS3 compliant? A: Yes. All identified substitute parts carry ROHS3 compliance status.

Q: Do all substitutes fit the same holder? A: Yes. All parts share the 5mm x 20mm package dimension and Requires Holder mounting type, ensuring mechanical compatibility with existing fuse holders.

Q: Which substitute has the highest inventory availability? A: 0213002.MXP has the highest inventory at 17,911 pieces. However, it has lower Breaking Capacity (35 A) and should be selected only if circuit requirements permit.

Request Quote (Ships tomorrow)