Request Quote
(Ships tomorrow)
Littelfuse 0218.400VXP Glass Cartridge Fuse 400mA 250VAC 5x20mm Equivalent & Substitute Parts
Part Overview
The Littelfuse 0218.400VXP is a 400mA 250VAC slow-blow glass cartridge fuse in 5x20mm form factor, designed for circuit protection in AC/DC applications. This Active product requires a fuse holder for installation and is RoHS3 compliant with multiple international certifications including UL, CE, CSA, and VDE. Equivalent and substitute parts are identified based on matching electrical ratings, mechanical dimensions, response characteristics, and approval agency compliance to ensure direct functional interchangeability in protected circuits.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Current Rating | 400 mA |
| Voltage Rating (AC) | 250 V |
| Fuse Type | Cartridge, Glass |
| Response Time | Slow Blow |
| Package / Case | 5mm x 20mm |
| Mounting Type | Requires Holder |
| Breaking Capacity @ Rated Voltage | 35A |
| Operating Temperature Range | -55°C ~ 125°C |
| RoHS Status | ROHS3 Compliant |
| Product Status | Active |
Substitute Part Grouping Explanation
Substitution eligibility for the 0218.400VXP is determined by the following critical parameters:
Primary Matching Criteria:
- Current Rating: 400 mA (exact match required)
- Voltage Rating (AC): 250 V (exact match required)
- Package / Case: 5mm x 20mm (exact match required)
- Fuse Type: Cartridge, Glass (exact match required)
- Response Time: Slow Blow (exact match required)
- Mounting Type: Requires Holder (exact match required)
Secondary Compatibility Factors:
- Breaking Capacity @ Rated Voltage: 35A minimum
- Operating Temperature Range: -55°C ~ 125°C minimum
- Approval Agency certifications: UL, CE, CSA, VDE preferred for regulatory alignment
- RoHS3 Compliance: Required for environmental standards
All substitute parts listed meet or exceed these criteria and are confirmed Active products with current inventory availability.
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Series | Current Rating | Voltage Rating (AC) | Response Time | Package / Case | Breaking Capacity @ Rated Voltage | Melting I²t | Operating Temperature | Approval Agency | Inventory (Pcs) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 0218.400VXP | Littelfuse Inc. | 218 | 400 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 1.325 | -55°C ~ 125°C | CCC, CE, CSA, KC, SEMKO, UL, VDE | 725 |
| 0213.400MXP | Littelfuse | 213 | 400 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 1.36 | -55°C ~ 125°C | BSI, CCC, CE, CSA, SEMKO, UR, VDE | 1252 |
| 0218.400HXP | Littelfuse Inc. | 218 | 400 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 1.325 | -55°C ~ 125°C | CCC, CE, CSA, K-MARK, SEMKO, UL, VDE | 4283 |
| 0218.400MXP | Littelfuse Inc. | 218 | 400 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 1.325 | -55°C ~ 125°C | CCC, CE, CSA, K-MARK, SEMKO, UL, VDE | 3680 |
| 0219.400MXAP | Littelfuse Inc. | 219XA | 400 mA | 250 V | Slow Blow | 5mm x 20mm | 150A | 1.4 | -55°C ~ 125°C | CCC, CE, CSA, SEMKO, UL, VDE | 1691 |
| 0239.400HXP | Littelfuse Inc. | 239 | 400 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 1.49 | -55°C ~ 125°C | CE, CSA, KC, UL | 899 |
| 0239.400MXP | Littelfuse Inc. | 239 | 400 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 1.49 | -55°C ~ 125°C | CE, CSA, KC, UL | 2059 |
| 0034.3113 | SCHURTER Inc. | FST 5x20 | 400 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 0.768 | -55°C ~ 125°C | CCC, cURus, VDE | 2229 |
| 0034.5613.11 | SCHURTER Inc. | SMD-FST | 400 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 0.768 | -55°C ~ 125°C | cURus, VDE | 1828 |
| TSC-400MA | OptiFuse | TSC | 400 mA | 250 V | Slow Blow | 5mm x 20mm | 100A | 1.2604 | -55°C ~ 125°C | cULus, UL 248 | 2439 |
| TSD-400MA | OptiFuse | TSD | 400 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 0.7968 | -55°C ~ 125°C | IEC 60127 | 4031 |
Engineering Selection Recommendations
Littelfuse Series 218 (0218.400HXP, 0218.400MXP): Direct equivalents within the same manufacturer series. Both parts share identical electrical specifications and melting I²t characteristics with the 0218.400VXP. Full UL, CE, CSA, and VDE certification alignment. Highest inventory availability (4283 and 3680 units respectively) supports supply chain continuity.
Littelfuse Series 213 (0213.400MXP): Parametric equivalent with marginally higher melting I²t (1.36 vs 1.325). Maintains all critical electrical and mechanical parameters. Includes BSI and UR certifications in addition to standard approvals. Suitable for applications requiring extended thermal margin.
Littelfuse Series 219XA (0219.400MXAP): Enhanced breaking capacity variant (150A vs 35A). Electrical and thermal characteristics compatible with base specification. Recommended for circuits requiring higher fault current withstand capability while maintaining identical current and voltage ratings.
Littelfuse Series 239 (0239.400HXP, 0239.400MXP): Parametric equivalents with higher melting I²t (1.49). Reduced approval agency coverage (CE, CSA, KC, UL) compared to 0218.400VXP. Suitable for applications where UL and VDE certifications are not mandatory requirements.
SCHURTER FST 5x20 (0034.3113): Cross-manufacturer equivalent from established supplier. Significantly lower melting I²t (0.768) indicates faster thermal response. CCC, cURus, and VDE certifications present. Suitable for applications tolerating tighter thermal margins.
SCHURTER SMD-FST (0034.5613.11): Parametric equivalent with identical melting I²t to 0034.3113 (0.768). Limited certification scope (cURus, VDE only). Recommended only where UL and CE certifications are not required.
OptiFuse TSC-400MA: Cross-manufacturer option with elevated breaking capacity (100A). Melting I²t (1.2604) falls between standard and enhanced variants. cULus and UL 248 certifications support North American applications. Suitable for circuits requiring higher fault current protection.
OptiFuse TSD-400MA: Cross-manufacturer equivalent with lowest melting I²t (0.7968) among all substitutes. IEC 60127 certification indicates international standards compliance. Highest inventory availability (4031 units). Recommended for cost-optimized procurement where IEC compliance is acceptable.
Frequently Asked Questions (FAQ)
Q: Can I substitute 0218.400VXP with any of the listed parts?
A: All listed parts meet the core electrical and mechanical requirements (400mA, 250VAC, 5x20mm, slow-blow, cartridge glass). However, verify that your application's certification requirements align with the substitute part's approval agencies. For example, if UL certification is mandatory, avoid 0034.5613.11 (cURus, VDE only).
Q: What is the significance of melting I²t values in the comparison table?
A: Melting I²t indicates the thermal energy required to melt the fuse element. Lower values (0.768 for SCHURTER parts) mean faster response to overcurrent. Higher values (1.49 for Series 239) provide greater tolerance to transient current spikes. Select based on your circuit's inrush current characteristics and protection speed requirements.
Q: Are Littelfuse Series 218 and 213 interchangeable?
A: Yes. Both share identical current rating (400mA), voltage rating (250VAC), package (5x20mm), and response time (slow-blow). The 0213.400MXP has marginally higher melting I²t (1.36 vs 1.325), making it suitable for applications with slightly higher transient current tolerance.
Q: Why does 0219.400MXAP have a higher breaking capacity (150A vs 35A)?
A: Breaking capacity indicates the maximum fault current the fuse can safely interrupt without rupturing the cartridge. The 0219.400MXAP is engineered for circuits with higher available fault current. This does not affect its 400mA current rating or 250VAC voltage rating. Use this variant only if your circuit's fault current exceeds 35A.
Q: Can I use OptiFuse TSD-400MA in place of Littelfuse 0218.400VXP?
A: Electrically and mechanically, yes. The TSD-400MA meets all core specifications. However, it carries IEC 60127 certification rather than UL/CE/CSA. Verify that your application or regional standards accept IEC 60127 compliance. The lower melting I²t (0.7968) means faster thermal response, which may affect circuit behavior if the original design relied on the Littelfuse thermal characteristics.
Q: What is the difference between SCHURTER 0034.3113 and 0034.5613.11?
A: Both are SCHURTER 400mA 250VAC 5x20mm slow-blow fuses with identical melting I²t (0.768). The primary difference is certification scope: 0034.3113 includes CCC certification, while 0034.5613.11 does not. Select 0034.3113 if CCC compliance is required for your market.
Q: Does package size affect fuse holder compatibility?
A: No. All substitute parts use the standard 5mm x 20mm cartridge form factor and require a fuse holder for installation, identical to the 0218.400VXP. Existing fuse holders are compatible with all listed substitutes.
Q: Which substitute offers the best inventory availability?
A: OptiFuse TSD-400MA has the highest inventory (4031 units), followed by Littelfuse 0218.400HXP (4283 units). For immediate procurement, these options provide the shortest lead times.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts