Request Quote
(Ships tomorrow)
Littelfuse 0217.050H Glass Cartridge Fuse 50mA 250VAC 5x20mm Equivalent & Substitute Parts
Part Overview
The Littelfuse 0217.050H is a 50mA 250VAC glass cartridge fuse in 5x20mm form factor with fast-blow response characteristics. This part is classified as obsolete, necessitating identification of active equivalent alternatives for ongoing component sourcing and system maintenance. Substitute parts must maintain identical electrical ratings, mechanical dimensions, and functional performance to ensure direct compatibility in existing applications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Current Rating | 50 mA |
| Voltage Rating (AC) | 250 V |
| Fuse Type | Cartridge, Glass |
| Response Time | Fast Blow |
| Package / Case | 5mm x 20mm |
| Breaking Capacity @ Rated Voltage | 35A |
| Melting I²t | 0.00019 |
| Operating Temperature Range | -55°C ~ 125°C |
| DC Cold Resistance | 15.2 Ohms |
| Mounting Type | Requires Holder |
Substitute Part Grouping Explanation
Substitution eligibility is determined by strict equivalence across the following critical parameters: current rating (50mA), voltage rating (250VAC), fuse type (cartridge glass), response time (fast blow), package dimensions (5x20mm), breaking capacity (35A), and melting I²t value (0.00019). All substitute parts listed maintain these specifications without deviation.
Littelfuse parametric equivalents (0217.050HXP, 0217.050MXBP, 0217.050MXP, 0217.050TXP, 0217.050VXP) are direct functional replacements with identical electrical and mechanical characteristics. These parts differ only in packaging configuration (bulk) and RoHS compliance status (ROHS3 compliant vs. non-compliant original).
Cross-manufacturer alternatives from Eaton (BK/GDB-50MA, BK/S500-50-R, BK1/S500-50-R) and SCHURTER (0034.1529.PT) maintain core electrical parameters but may exhibit minor variations in DC cold resistance and melting I²t values within acceptable engineering tolerances.
Parameter Comparison
| Part Number | Manufacturer | Current Rating | Voltage Rating (AC) | Response Time | Package | Breaking Capacity | Melting I²t | DC Cold Resistance | Product Status | RoHS Status |
|---|---|---|---|---|---|---|---|---|---|---|
| 0217.050H | Littelfuse Inc. | 50 mA | 250 V | Fast Blow | 5x20mm | 35A | 0.00019 | 15.2 Ohms | Obsolete | RoHS non-compliant |
| 0217.050HXP | Littelfuse Inc. | 50 mA | 250 V | Fast Blow | 5x20mm | 35A | 0.00019 | 15.2 Ohms | Active | ROHS3 Compliant |
| 0217.050MXBP | Littelfuse Inc. | 50 mA | 250 V | Fast Blow | 5x20mm | 35A | 0.00019 | 15.2 Ohms | Active | ROHS3 Compliant |
| 0217.050MXP | Littelfuse Inc. | 50 mA | 250 V | Fast Blow | 5x20mm | 35A | 0.00019 | 15.2 Ohms | Active | ROHS3 Compliant |
| 0217.050TXP | Littelfuse Inc. | 50 mA | 250 V | Fast Blow | 5x20mm | 35A | 0.00019 | 15.2 Ohms | Active | ROHS3 Compliant |
| 0217.050VXP | Littelfuse Inc. | 50 mA | 250 V | Fast Blow | 5x20mm | 35A | 0.00019 | 15.2 Ohms | Active | ROHS3 Compliant |
| BK/GDB-50MA | Eaton - Electronics Division | 50 mA | 250 V | Fast Blow | 5x20mm | 35A | 0.0002 | 17 Ohms | Active | RoHS Compliant |
| 0034.1529.PT | SCHURTER Inc. | 50 mA | 250 V | Fast Blow | 5x20mm (Axial) | 35A | 0.00025 | Not specified | Active | ROHS3 Compliant |
| BK/S500-50-R | Eaton - Electronics Division | 50 mA | 250 V | Fast Blow | 5x20mm | 35A | 0.0002 | 17 Ohms | Active | RoHS Compliant |
| BK1/S500-50-R | Eaton - Electronics Division | 50 mA | 250 V | Fast Blow | 5x20mm | 35A | 0.0002 | 17 Ohms | Active | RoHS Compliant |
Engineering Selection Recommendations
For direct replacement of the obsolete 0217.050H, Littelfuse parametric equivalents (0217.050HXP, 0217.050MXBP, 0217.050MXP, 0217.050TXP, 0217.050VXP) provide identical electrical and mechanical specifications with active product status and ROHS3 compliance. These parts are preferred for new designs and ongoing production requiring regulatory compliance.
Eaton S500 series fuses (BK/S500-50-R, BK1/S500-50-R) and GDB series (BK/GDB-50MA) are functionally equivalent alternatives with RoHS compliance. Minor variations in DC cold resistance (17 Ohms vs. 15.2 Ohms) and melting I²t (0.0002 vs. 0.00019) fall within acceptable engineering tolerances for 50mA fast-blow applications.
SCHURTER 0034.1529.PT offers compatibility with identical electrical ratings and ROHS3 compliance. This part features through-hole mounting and slightly larger physical dimensions (5.40mm x 22.50mm) compared to standard 5x20mm cartridges, requiring mechanical fit verification in existing holder assemblies.
Frequently Asked Questions (FAQ)
Q: Can Littelfuse 0217.050HXP directly replace the obsolete 0217.050H?
A: Yes. The 0217.050HXP maintains identical current rating (50mA), voltage rating (250VAC), response time (fast blow), package dimensions (5x20mm), breaking capacity (35A), and melting I²t (0.00019). The only differences are packaging configuration and ROHS3 compliance status.
Q: Are Eaton S500 series fuses compatible with Littelfuse holders?
A: Yes. Eaton BK/S500-50-R and BK1/S500-50-R maintain the standard 5x20mm cartridge form factor and are mechanically compatible with Littelfuse fuse holders. Electrical performance is equivalent within acceptable tolerances.
Q: What is the significance of the melting I²t parameter in substitution?
A: Melting I²t determines the thermal energy required to melt the fuse element and is critical for circuit protection coordination. Littelfuse parts specify 0.00019, while Eaton alternatives specify 0.0002. This minor variation (approximately 5% difference) does not affect functional compatibility in standard 50mA applications.
Q: Why does SCHURTER 0034.1529.PT have different physical dimensions?
A: The SCHURTER part is configured for through-hole mounting with axial leads (5.40mm x 22.50mm) versus the standard cartridge form factor (5.20mm x 20.00mm). Mechanical compatibility depends on the specific holder design. Verify dimensional fit before substitution.
Q: Which substitute part offers the best compliance profile?
A: All active substitute parts listed (Littelfuse 0217.050HXP/MXBP/MXP/TXP/VXP, Eaton S500 series, SCHURTER 0034.1529.PT) are RoHS compliant. Littelfuse parametric equivalents carry ROHS3 certification and are recommended for applications requiring the highest regulatory compliance standards.
Q: Can I use BK1/S500-4-R as a substitute?
A: No. BK1/S500-4-R is rated for 4A current, not 50mA. Current rating is a non-negotiable substitution parameter. Using an incorrect current rating will result in improper circuit protection.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts