Littelfuse 0213.630TXP Glass Cartridge Fuse 630mA 250VAC 5x20mm Equivalent & Substitute Parts
Part Overview
The Littelfuse 0213.630TXP is a slow-blow glass cartridge fuse rated for 630mA at 250V AC/DC with a 5mm x 20mm form factor. This component is designed for circuit protection in applications requiring holder-mounted fuse cartridges. The part maintains active product status with full RoHS3 compliance and international safety certifications. Substitute parts are identified based on matching electrical ratings, mechanical dimensions, response characteristics, and approval agency compliance to ensure direct functional equivalence in circuit protection applications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Current Rating | 630 mA |
| Voltage Rating (AC) | 250 V |
| Fuse Type | Cartridge, Glass |
| Response Time | Slow Blow |
| Package / Case | 5mm x 20mm |
| Mounting Type | Requires Holder |
| Breaking Capacity @ Rated Voltage | 35A |
| Operating Temperature Range | -55°C ~ 125°C |
| RoHS Status | ROHS3 Compliant |
| Product Status | Active |
Substitute Part Grouping Explanation
Substitute parts for the 0213.630TXP are grouped based on strict electrical and mechanical parameter matching. All identified substitutes maintain the following core criteria:
- Current Rating: 630 mA (exact match)
- Voltage Rating: 250 V AC (exact match)
- Package Dimensions: 5mm x 20mm (exact match)
- Fuse Type: Cartridge, Glass (exact match)
- Response Time: Slow Blow (exact match)
- Mounting: Requires Holder (exact match)
- Operating Temperature: -55°C ~ 125°C (exact match)
- RoHS3 Compliance: All substitutes maintain compliance
Substitutes are sourced from Littelfuse series 213, 218, 219XA, and 618, as well as cross-manufacturer equivalents from SCHURTER and OptiFuse. Variations in Breaking Capacity and Melting I²t values are noted but do not preclude substitution when application requirements align with the specified ratings.
Parameter Comparison
| Part Number | Manufacturer | Series | Current Rating | Voltage Rating (AC) | Response Time | Package | Breaking Capacity @ Rated Voltage | Melting I²t | Operating Temperature | RoHS Status |
|---|---|---|---|---|---|---|---|---|---|---|
| 0213.630TXP | Littelfuse Inc. | 213 | 630 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 4.8 | -55°C ~ 125°C | ROHS3 Compliant |
| 0213.630MXP | Littelfuse Inc. | 213 | 630 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 4.8 | -55°C ~ 125°C | ROHS3 Compliant |
| 0218.630HXP | Littelfuse Inc. | 218 | 630 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 4.675 | -55°C ~ 125°C | ROHS3 Compliant |
| 0218.630MXP | Littelfuse | 218 | 630 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 4.675 | -55°C ~ 125°C | ROHS3 Compliant |
| 0218.630TXP | Littelfuse Inc. | 218 | 630 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 4.675 | -55°C ~ 125°C | ROHS3 Compliant |
| 0219.630MXAP | Littelfuse Inc. | 219XA | 630 mA | 250 V | Slow Blow | 5mm x 20mm | 150A | 4.82 | -55°C ~ 125°C | ROHS3 Compliant |
| 0618.630MXP | Littelfuse Inc. | 618 | 630 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 4.675 | -55°C ~ 125°C | ROHS3 Compliant |
| 0034.3115 | SCHURTER Inc. | FST 5x20 | 630 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 4.35 | -55°C ~ 125°C | ROHS3 Compliant |
| TSC-630MA | OptiFuse | TSC | 630 mA | 250 V | Slow Blow | 5mm x 20mm | 100A | 0.566 | -55°C ~ 125°C | ROHS3 Compliant |
| TSD-630MA | OptiFuse | TSD | 630 mA | 250 V | Slow Blow | 5mm x 20mm | 35A | 1.583 | -55°C ~ 125°C | ROHS3 Compliant |
Engineering Selection Recommendations
All listed substitute parts maintain electrical and mechanical compatibility with the 0213.630TXP based on matching current rating, voltage rating, package dimensions, and response characteristics. Selection among substitutes should be based on:
Littelfuse Series 213 and 218 Substitutes: These parts offer direct compatibility with identical or equivalent electrical performance. Series 213 parts (0213.630MXP) and Series 218 parts (0218.630HXP, 0218.630MXP, 0218.630TXP) maintain the same breaking capacity and melting I²t characteristics as the primary part. The 0219.630MXAP variant offers increased breaking capacity (150A) while maintaining all other electrical parameters.
Littelfuse Series 618 Substitute: The 0618.630MXP provides equivalent electrical performance with identical breaking capacity and similar melting I²t values.
Cross-Manufacturer Substitutes: The SCHURTER 0034.3115 (FST 5x20 series) and OptiFuse TSC-630MA and TSD-630MA parts provide functional equivalence with matching current, voltage, and package specifications. OptiFuse parts carry different approval agency certifications (cULus, UL 248 for TSC-630MA; IEC 60127 for TSD-630MA) compared to the primary part.
All substitutes maintain active product status and RoHS3 compliance. Selection should account for application-specific approval agency requirements and breaking capacity specifications.
Frequently Asked Questions (FAQ)
Q: Can I substitute the 0213.630TXP with any of the listed parts?
A: Yes, all listed parts are electrically and mechanically equivalent based on matching 630mA current rating, 250V AC voltage rating, 5mm x 20mm package dimensions, and slow-blow response time. Verify that the substitute part's approval agency certifications align with your application requirements.
Q: What is the difference between the Littelfuse series (213, 218, 219XA, 618) substitutes?
A: All Littelfuse series maintain identical electrical ratings and package dimensions. The primary differences are in breaking capacity and melting I²t values. Series 219XA (0219.630MXAP) offers higher breaking capacity (150A) compared to other series (35A). Series 218 and 618 parts have slightly lower melting I²t values (4.675) compared to Series 213 (4.8).
Q: Are OptiFuse parts direct substitutes?
A: OptiFuse TSC-630MA and TSD-630MA parts match the electrical and mechanical specifications of the 0213.630TXP. However, they carry different approval agency certifications. TSC-630MA is certified to cULus and UL 248, while TSD-630MA is certified to IEC 60127. Confirm that these certifications meet your application requirements before substitution.
Q: What is the significance of Breaking Capacity differences?
A: Breaking capacity indicates the maximum fault current the fuse can safely interrupt. The 0213.630TXP has a 35A breaking capacity. The 0219.630MXAP offers 150A breaking capacity, and TSC-630MA offers 100A. Higher breaking capacity provides greater protection margin in high-fault-current applications but does not affect normal operation at rated current.
Q: Can I use the SCHURTER 0034.3115 as a substitute?
A: Yes, the SCHURTER 0034.3115 (FST 5x20 series) is electrically and mechanically equivalent with matching 630mA and 250V ratings. It carries CCC, cURus, and VDE certifications. Verify compatibility with your application's certification requirements.
Q: Do all substitutes have the same operating temperature range?
A: Yes, all listed substitutes operate across the -55°C to 125°C temperature range, matching the primary part specification.
Q: Are there inventory considerations for substitute selection?
A: Inventory levels vary among substitutes. The SCHURTER 0034.3115 has the highest inventory (10,758 pcs), while the 0218.630TXP has the lowest (792 pcs). Consider lead time and availability requirements when selecting among equivalent parts.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts