Request Quote
(Ships tomorrow)
SCHURTER 0034.3422 Equivalent & Substitute Parts
Part Overview
The SCHURTER 0034.3422 is a 3.15 A, 250 V AC/DC slow-blow glass fuse cartridge in 3AB/3AG package format (1/4" x 1-1/4"). This component is classified as obsolete, making substitute parts necessary for ongoing system maintenance and new designs. The fuse requires a compatible holder for installation and is designed for general-purpose circuit protection applications requiring slow-blow response characteristics.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 0034.3422 |
| Manufacturer | SCHURTER Inc. |
| Current Rating | 3.15 A |
| Voltage Rating (AC) | 250 V |
| Fuse Type | Cartridge, Glass |
| Response Time | Slow Blow |
| Package / Case | 3AB, 3AG, 1/4" x 1-1/4" |
| Size / Dimension | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) |
| Operating Temperature Range | -55°C ~ 125°C |
| Product Status | Obsolete |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution for the SCHURTER 0034.3422 is determined by the following critical parameters:
Primary Substitution Criteria:
- Current Rating: 3.15 A (tolerance range 3.15 A to 3.2 A acceptable)
- Voltage Rating: 250 V AC minimum
- Response Time: Slow Blow
- Package Format: 3AB/3AG cartridge, 1/4" x 1-1/4" dimensions
- Mounting Type: Requires Holder
Secondary Compatibility Factors:
- Fuse Type: Glass or ceramic cartridge construction
- Operating Temperature: Minimum -55°C ~ 125°C range
- RoHS Compliance: ROHS3 Compliant
- Approval Agencies: CE certification required
Two substitute parts meet these criteria with varying trade-offs in voltage rating, fuse material, and breaking capacity.
Parameter Comparison
| Parameter | 0034.3422 (Main) | 8020.5016 (Substitute) | 031303.2MXP (Substitute) |
|---|---|---|---|
| Manufacturer | SCHURTER Inc. | SCHURTER Inc. | Littelfuse Inc. |
| Current Rating (A) | 3.15 | 3.15 | 3.2 |
| Voltage Rating (AC) | 250 V | 500 V | 250 V |
| Fuse Type | Cartridge, Glass | Cartridge, Ceramic | Cartridge, Glass |
| Response Time | Slow Blow | Slow Blow | Slow Blow |
| Package / Case | 3AB, 3AG, 1/4" x 1-1/4" | Cartridge, Non-Standard | 3AB, 3AG, 1/4" x 1-1/4" |
| Size / Dimension | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | 0.250" Dia x 1.252" L (6.35mm x 31.80mm) | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) |
| Operating Temperature | -55°C ~ 125°C | -40°C ~ 85°C | -55°C ~ 125°C |
| Breaking Capacity @ Rated Voltage | 35 A | 1.5 kA | 100 A |
| Product Status | Obsolete | Active | Active |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
| Approval Agency | CE | cURus | CE, CSA, K-MARK, PSE, UL |
Engineering Selection Recommendations
Littelfuse 031303.2MXP is the primary substitute for the SCHURTER 0034.3422. This part maintains identical voltage rating (250 V AC), package format (3AB/3AG, 1/4" x 1-1/4"), fuse type (glass cartridge), and operating temperature range (-55°C ~ 125°C). Current rating is 3.2 A, within acceptable tolerance of the original 3.15 A specification. The part holds active product status with comprehensive approval certifications (CE, CSA, K-MARK, PSE, UL), ensuring regulatory compliance across multiple markets.
SCHURTER 8020.5016 serves as an alternative substitute when higher voltage rating (500 V AC) is required. This ceramic cartridge fuse maintains the same current rating (3.15 A) and slow-blow response. However, the package format is listed as non-standard, and the operating temperature range is reduced (-40°C ~ 85°C). This substitute is suitable only when system voltage requirements exceed 250 V and holder compatibility can be confirmed.
Selection between substitutes depends on system voltage requirements and operating environment temperature specifications. For standard 250 V applications within the -55°C ~ 125°C range, the Littelfuse part is the direct equivalent. For higher voltage systems, the SCHURTER ceramic option provides enhanced voltage capability with trade-offs in temperature range and package standardization.
Frequently Asked Questions (FAQ)
Q: Can the Littelfuse 031303.2MXP directly replace the SCHURTER 0034.3422 without holder modification?
A: Yes. Both parts use the identical 3AB/3AG package format with 1/4" x 1-1/4" dimensions (6.35mm x 31.75mm). The Littelfuse part is mechanically and electrically compatible with existing holders designed for the original SCHURTER fuse.
Q: What is the significance of the 3.2 A rating on the Littelfuse part versus the 3.15 A original?
A: The 3.2 A rating represents a 1.6% increase in current capacity. This falls within standard tolerance ranges for fuse specifications and does not compromise circuit protection. The part remains suitable for protecting 3.15 A circuits.
Q: Why is the SCHURTER 8020.5016 listed as a substitute if it has a non-standard package?
A: The 8020.5016 is included as a substitute option for applications requiring 500 V AC voltage rating. The non-standard package designation indicates dimensional or holder compatibility differences that must be verified before implementation. This part is suitable only when voltage requirements exceed 250 V and holder compatibility is confirmed.
Q: What is the difference between glass and ceramic fuse cartridges in these substitutes?
A: Glass cartridges (0034.3422 and 031303.2MXP) provide visibility of the fuse element and are standard for general-purpose applications. Ceramic cartridges (8020.5016) offer higher breaking capacity (1.5 kA versus 35 A or 100 A) and are used in applications requiring enhanced fault current handling. Material selection depends on system fault current levels and application requirements.
Q: Are all substitute parts RoHS3 compliant?
A: Yes. Both substitute parts (8020.5016 and 031303.2MXP) are ROHS3 compliant, matching the compliance status of the original SCHURTER 0034.3422.
Q: Which substitute has the broadest regulatory approval?
A: The Littelfuse 031303.2MXP holds the most comprehensive certifications: CE, CSA, K-MARK, PSE, and UL. This makes it suitable for applications requiring multi-market regulatory compliance. The SCHURTER 8020.5016 holds cURus certification, which covers North American markets.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts