Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts Reference for Vicor VI-B7L-MX DC DC Converter
Part Overview
The Vicor VI-B7L-MX is an isolated DC DC converter module in the VI-200™ (75W) series. It features a single 28V output at up to 2.68A, accepts input voltages from 100V to 375V, offers 3kV isolation, and includes protection features such as OCP, OTP, OVP, and SCP. The product is classified as obsolete. Identifying alternative models with identical electrical and mechanical parameters is essential for current designs, maintenance, and inventory continuity.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | VI-B7L-MX |
| Series | VI-200™ (75W) |
| Product Status | Obsolete |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 100V |
| Voltage - Input (Max) | 375V |
| Voltage - Output 1 | 28V |
| Current - Output (Max) | 2.68A |
| Power (Watts) | 75 W |
| Voltage - Isolation | 3 kV |
| Operating Temperature | -55°C ~ 85°C |
| Efficiency | 90% |
| Mounting Type | Through Hole |
| Package / Case | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) |
| RoHS Status | RoHS non-compliant |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute part selection for the Vicor VI-B7L-MX DC DC converter is strictly based on matching crucial parameters: input voltage range (100V–375V), output voltage and current ratings (28V, 2.68A, 75W), isolation (3kV), operating temperature (-55°C to 85°C), electrical efficiency (90%), through-hole mounting, full brick package, and protection features. Compliance, inventory status, and dimensions are included as allowed by category specifications.
Parameter Comparison
| Parameter | VI-B7L-MX | VI-B7L-MX-B1 |
|---|---|---|
| Manufacturer | Vicor Corporation | Vicor Corporation |
| Series | VI-200™ (75W) | VI-200™ (75W) |
| Product Status | Obsolete | Active |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 100V | 100V |
| Voltage - Input (Max) | 375V | 375V |
| Voltage - Output 1 | 28V | 28V |
| Current - Output (Max) | 2.68A | 2.68A |
| Power (Watts) | 75 W | 75 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | OCP, OTP, OVP, SCP | OCP, OTP, OVP, SCP |
| Operating Temperature | -55°C ~ 85°C | -55°C ~ 85°C |
| Efficiency | 90% | 90% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Full Brick | Full Brick |
| Size / Dimension | 4.60" L x 2.40" W x 0.50" H (116.8mm x 61.0mm x 12.7mm) | 4.60" L x 2.40" W x 1.07" H (116.8mm x 61.0mm x 27.1mm) |
| RoHS Status | RoHS non-compliant | RoHS non-compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
Selection between the Vicor VI-B7L-MX and VI-B7L-MX-B1 DC DC converters is determined by product status and regulatory compliance. VI-B7L-MX is obsolete; substitution by VI-B7L-MX-B1 is supported due to identical electrical and isolating parameters, application category, compliance status, and series grouping. Dimensional differences in height must be considered for mechanical integration.
Frequently Asked Questions (FAQ)
Q1: What substitution criteria are applied for Vicor DC DC converters in this category? A: Substitution is strictly based on input and output voltages, output current, total power rating, isolation voltage, operating temperature range, features, mounting method, package type, and regulatory compliance.
Q2: Are the electrical parameters of VI-B7L-MX and VI-B7L-MX-B1 identical? A: Yes, input voltage, output voltage, output current, isolation, efficiency, and operating temperature are identical.
Q3: Does the substitute part have a different package size? A: Yes, the VI-B7L-MX-B1 has a greater package height (1.07") compared to VI-B7L-MX (0.50"). Length and width are the same.
Q4: Is product status a critical factor in substitution? A: Yes, VI-B7L-MX is obsolete; VI-B7L-MX-B1 is active, which is important for sourcing and lifecycle planning.
Q5: Are there differences in compliance or certifications between the two parts? A: Both parts share identical RoHS non-compliance, REACH status, ECCN, and HTSUS codes.
Q6: Should mounting type be checked when substituting? A: Both parts use through-hole mounting, which supports compatibility for PCB assembly. Only the height dimension varies.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts