TS-709-5 Thermal Circuit Breaker Equivalent & Substitute Parts

Part Overview

The TS-709-5 is a thermal circuit breaker manufactured by SCHURTER Inc., rated for 5A at 250V AC / 50V DC with push-to-reset panel mount actuation. This part is classified as obsolete, making equivalent and substitute parts necessary for ongoing system maintenance and new design implementations. The TS-709-5 series breaker provides single-pole thermal protection suitable for industrial control and power distribution applications requiring CSA C22.2 and UL1077 compliance.

Substiute Parts

TS-709-5
SCHURTER Inc.In Stock: 1261TS-709-5 Datasheet
TS-709-5
Current Part
4404.0025
SCHURTER Inc.In Stock: 8814404.0025 Datasheet
4404.0025
Similar
CMB-053-11CNN-B-A
Carling TechnologiesIn Stock: 800CMB-053-11CNN-B-A Datasheet
CMB-053-11CNN-B-A
Similar
CMB-053-11DNN-B-A
Carling TechnologiesIn Stock: 1190CMB-053-11DNN-B-A Datasheet
CMB-053-11DNN-B-A
Similar
1140-E211-P1M1-5A
E-T-AIn Stock: 10631140-E211-P1M1-5A Datasheet
1140-E211-P1M1-5A
Parametric Equivalent
1140-G111-P1M1-5A
E-T-AIn Stock: 10281140-G111-P1M1-5A Datasheet
1140-G111-P1M1-5A
Parametric Equivalent
1140-G151-P7M1-5A
E-T-AIn Stock: 21341140-G151-P7M1-5A Datasheet
1140-G151-P7M1-5A
Parametric Equivalent
127-P10-H-KF-050022-5A
127-P10-H-KF-050022-5A
Parametric Equivalent
127-P10-H-KF-5A
E-T-AIn Stock: 741127-P10-H-KF-5A Datasheet
127-P10-H-KF-5A
Parametric Equivalent
127-P10-H-KF-D91-5A
127-P10-H-KF-D91-5A
Parametric Equivalent
1410-G110-P2F1-S01-5A
1410-G110-P2F1-S01-5A
Parametric Equivalent
1410-G111-P2F1-S01-5A
1410-G111-P2F1-S01-5A
Parametric Equivalent
1410-G114-P3F1-S01-5A
1410-G114-P3F1-S01-5A
Parametric Equivalent
157-K10-KF-5A
E-T-AIn Stock: 706157-K10-KF-5A Datasheet
157-K10-KF-5A
Parametric Equivalent
2-5000-P10-H-5A
E-T-AIn Stock: 10402-5000-P10-H-5A Datasheet
2-5000-P10-H-5A
Parametric Equivalent
CTB-B-B-05
Carling TechnologiesIn Stock: 1778CTB-B-B-05 Datasheet
CTB-B-B-05
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number TS-709-5
Manufacturer SCHURTER Inc.
Series TS
Current Rating 5A
Voltage Rating - AC 250V
Voltage Rating - DC 50V
Breaker Type Thermal
Actuator Type Push to Reset
Mounting Type Panel Mount
Number of Poles 1
Product Status Obsolete
Approval Agencies CSA C22.2, UL1077
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the TS-709-5 is determined by the following critical parameters:

Primary Matching Criteria:

  • Current Rating: 5A (exact match required)
  • Breaker Type: Thermal (exact match required)
  • Actuator Type: Push to Reset (exact match required)
  • Mounting Type: Panel Mount (exact match required)
  • Number of Poles: 1 (exact match required)

Voltage Compatibility Criteria:

  • AC Voltage: 250V minimum required
  • DC Voltage: 50V minimum required

Compliance Criteria:

  • Approval agencies must include UL1077 as minimum standard
  • RoHS3 compliance required for new designs

Substitute parts are grouped into two categories: parametric equivalents (identical electrical and mechanical specifications) and similar alternatives (matching core function with acceptable voltage derating).

Parameter Comparison

Part Number Manufacturer Current (A) AC Voltage DC Voltage Breaker Type Actuator Mounting Poles Status Approvals
TS-709-5 SCHURTER Inc. 5 250V 50V Thermal Push to Reset Panel Mount 1 Obsolete CSA C22.2, UL1077
4404.0025 SCHURTER Inc. 5 240V 48V Thermal Push to Reset Panel Mount 1 Active CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077
CMB-053-11CNN-B-A Carling Technologies 5 250V 32V Thermal Push to Reset Panel Mount 1 Active CE, cUL, TUV, UL1077, UL1500
CMB-053-11DNN-B-A Carling Technologies 5 250V 32V Thermal Push to Reset Panel Mount 1 Active CE, cUL, TUV, UL1077, UL1500
1140-E211-P1M1-5A E-T-A 5 250V 50V Thermal Push to Reset Panel Mount 1 Active CSA C22.2 No 235, IEC 60934, UL1077
1140-G111-P1M1-5A E-T-A 5 250V 50V Thermal Push to Reset Panel Mount 1 Active CSA C22.2 No 235, IEC 60934, UL1077
1140-G151-P7M1-5A E-T-A 5 250V 50V Thermal Push to Reset Panel Mount 1 Active CSA C22.2 No 235, IEC 60934, UL1077
127-P10-H-KF-050022-5A E-T-A 5 250V 50V Thermal Push to Reset Panel Mount 1 Active CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
127-P10-H-KF-5A E-T-A 5 250V 50V Thermal Push to Reset Panel Mount 1 Active CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
127-P10-H-KF-D91-5A E-T-A 5 250V 50V Thermal Push to Reset Panel Mount 1 Active CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
1410-G110-P2F1-S01-5A E-T-A 5 250V 50V Thermal Push to Reset Panel Mount 1 Active CSA C22.2 No 235, IEC 60934, UL1077

Engineering Selection Recommendations

Parametric Equivalents (Direct Replacement): The E-T-A 1140 series (1140-E211-P1M1-5A, 1140-G111-P1M1-5A, 1140-G151-P7M1-5A) and 127 series (127-P10-H-KF-050022-5A, 127-P10-H-KF-5A, 127-P10-H-KF-D91-5A) and 1410-G110-P2F1-S01-5A provide identical electrical specifications (5A, 250V AC, 50V DC) with active product status. These parts carry CSA C22.2 No 235, IEC 60934, and UL1077 certifications, meeting or exceeding the original TS-709-5 compliance requirements. E-T-A parts are preferred for direct substitution due to specification matching and active manufacturing status.

Voltage-Derated Alternatives: The SCHURTER 4404.0025 operates at 240V AC / 48V DC, representing a minor voltage derating from the original 250V AC / 50V DC specification. This part maintains 5A thermal protection with identical mechanical form factor and push-to-reset actuation. The 4404.0025 is suitable for applications where the lower voltage ratings are acceptable within system design margins.

Cross-Manufacturer Alternatives: Carling Technologies CMB-053-11CNN-B-A and CMB-053-11DNN-B-A provide 5A thermal protection at 250V AC with reduced DC voltage rating (32V). These parts carry expanded certifications including CE, cUL, TUV, UL1077, and UL1500. DC voltage derating to 32V requires system-level evaluation before implementation.

Active Product Status Priority: All recommended substitutes maintain active manufacturing status, ensuring long-term availability and supply chain continuity compared to the obsolete TS-709-5.

Frequently Asked Questions (FAQ)

Q: Can I use the SCHURTER 4404.0025 as a direct replacement for TS-709-5? A: The 4404.0025 is mechanically and functionally compatible but operates at reduced voltage ratings (240V AC / 48V DC versus 250V AC / 50V DC). Substitution is acceptable only if your application operates within these lower voltage specifications.

Q: What is the difference between E-T-A 1140 and 127 series breakers? A: Both series provide identical electrical specifications (5A, 250V AC, 50V DC) and certifications. The difference lies in mechanical packaging and mounting interface details. Verify mechanical compatibility with your panel mount configuration before selection.

Q: Are Carling Technologies CMB-053 breakers suitable replacements? A: CMB-053-11CNN-B-A and CMB-053-11DNN-B-A match the 5A current rating and 250V AC specification but operate at 32V DC maximum. These are suitable only if your DC voltage requirement does not exceed 32V. Both carry UL1077 certification required for this application.

Q: Why is the TS-709-5 listed as obsolete? A: Obsolete status indicates SCHURTER Inc. has discontinued manufacturing. Active alternatives from E-T-A and Carling Technologies provide equivalent functionality with ongoing production support.

Q: Do all substitute parts have the same approval certifications? A: No. The original TS-709-5 requires CSA C22.2 and UL1077 minimum. All recommended E-T-A substitutes meet or exceed this requirement. Carling Technologies parts add CE, cUL, and TUV certifications. Verify your application's specific certification requirements before final selection.

Q: What packaging options are available for substitute parts? A: E-T-A parts are supplied in bulk packaging. SCHURTER 4404.0025 is supplied in box packaging. Carling Technologies CMB-053 series is supplied in bulk packaging. Confirm packaging requirements with your procurement process.

Q: Can I mix different substitute part numbers in the same system? A: All recommended substitutes are mechanically and electrically compatible for panel mount installation. However, maintaining consistent part numbers within a system simplifies maintenance and spare parts inventory management.

Request Quote (Ships tomorrow)