RFNA4PCCD N Type Coaxial Connector Equivalent & Substitute Parts

Part Overview

The RFNA4PCCD is an N Type Connector Plug with male pin configuration manufactured by Bulgin, designed for 50 Ohm RF applications requiring panel mount installation. This connector features compression contact termination and screw shield termination, operating across a frequency range up to 18 GHz with an operating temperature range of -55°C to 155°C. The part is currently Active in product status with 1073 pieces available in inventory. Substitute parts are identified to provide alternative sourcing options when the primary part number is unavailable or when inventory requirements necessitate alternative stock sources.

Substiute Parts

RFNA4PCCD
BulginIn Stock: 1181RFNA4PCCD Datasheet
RFNA4PCCD
Current Part
RFNA4PGID
BulginIn Stock: 1256RFNA4PGID Datasheet
RFNA4PGID
Parametric Equivalent

Key Parameters

Parameter Value
Connector Style N Type
Connector Type Plug, Male Pin
Impedance 50 Ohms
Mounting Type Panel Mount
Mounting Feature Flange
Contact Termination Compression
Shield Termination Screw
Frequency - Max 18 GHz
Operating Temperature -55°C ~ 155°C
Voltage Rating 500 V
Mating Cycles 500
Center Contact Material Beryllium Copper
Body Material Stainless Steel
Dielectric Material Polyetherimide (PEI)
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited)

Substitute Part Grouping Explanation

The RFNA4PCCD and its substitute part RFNA4PGID are classified as parametric equivalents based on identical electrical and mechanical specifications. Substitution is valid when the following critical parameters match across both part numbers:

  • Connector Style: N Type
  • Connector Type: Plug, Male Pin
  • Impedance: 50 Ohms
  • Mounting Type: Panel Mount with Flange
  • Contact Termination: Compression
  • Shield Termination: Screw
  • Frequency - Max: 18 GHz
  • Operating Temperature Range: -55°C ~ 155°C
  • Voltage Rating: 500 V
  • Mating Cycles: 500
  • Center Contact Material: Beryllium Copper
  • Body Material: Stainless Steel
  • Dielectric Material: Polyetherimide (PEI)
  • RoHS Status: ROHS3 Compliant
  • Moisture Sensitivity Level: 1 (Unlimited)

Both parts share the same base product number (RFNA) and are manufactured by Bulgin. The substitute part maintains full electrical and mechanical compatibility with the primary part number.

Parameter Comparison

Parameter RFNA4PCCD RFNA4PGID
Manufacturer Bulgin Bulgin
Category Coaxial Connectors (RF) Coaxial Connectors (RF)
Connector Style N Type N Type
Connector Type Plug, Male Pin Plug, Male Pin
Impedance 50 Ohms 50 Ohms
Mounting Type Panel Mount Panel Mount
Mounting Feature Flange Flange
Contact Termination Compression Compression
Shield Termination Screw Screw
Fastening Type Threaded Threaded
Frequency - Max 18 GHz 18 GHz
Number of Ports 1 1
Housing Color Silver Silver
Center Contact Material Beryllium Copper Beryllium Copper
Body Material Stainless Steel Stainless Steel
Dielectric Material Polyetherimide (PEI) Polyetherimide (PEI)
Operating Temperature -55°C ~ 155°C -55°C ~ 155°C
Voltage Rating 500 V 500 V
Mating Cycles 500 500
Base Product Number RFNA RFNA
RoHS Status ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited)
ECCN EAR99 EAR99
HTSUS 8536.69.4010 8536.69.4010
Product Status Active Active
Inventory 1073 Pcs 1171 Pcs

Engineering Selection Recommendations

Both RFNA4PCCD and RFNA4PGID are Active products manufactured by Bulgin with identical electrical and mechanical specifications. Selection between these part numbers is based on inventory availability and supply chain requirements rather than technical performance differences.

RFNA4PCCD is suitable for applications requiring N Type 50 Ohm RF connectors with panel mount flange installation, compression contact termination, and operation across -55°C to 155°C temperature ranges up to 18 GHz frequency. The part maintains ROHS3 compliance and is rated for 500 mating cycles.

RFNA4PGID provides an equivalent alternative with identical performance characteristics and compliance certifications. The substitute part is available with higher inventory levels (1171 pieces versus 1073 pieces), offering enhanced supply chain flexibility.

Both parts are suitable for direct substitution in RF applications where N Type male plug connectors with 50 Ohm impedance and panel mount configuration are specified.

Frequently Asked Questions (FAQ)

Q: Can RFNA4PGID be used as a direct replacement for RFNA4PCCD?

A: Yes. Both parts are parametric equivalents with identical electrical and mechanical specifications, including connector style, impedance, frequency rating, operating temperature range, voltage rating, and mating cycle rating. Direct substitution is valid for all applications where RFNA4PCCD is specified.

Q: What are the key electrical parameters that define substitution compatibility?

A: The critical electrical parameters are 50 Ohm impedance, 18 GHz maximum frequency, 500 V voltage rating, and N Type connector style with male pin configuration. Both substitute parts maintain these specifications identically.

Q: Are there any mechanical differences between RFNA4PCCD and RFNA4PGID?

A: No. Both parts feature identical mechanical specifications including panel mount flange mounting, compression contact termination, screw shield termination, stainless steel body construction, and beryllium copper center contact material.

Q: What is the operating temperature range for these connectors?

A: Both RFNA4PCCD and RFNA4PGID operate across -55°C to 155°C, providing performance across extended temperature environments.

Q: Are both parts RoHS compliant?

A: Yes. Both RFNA4PCCD and RFNA4PGID are ROHS3 compliant with Moisture Sensitivity Level 1 (Unlimited).

Q: What is the maximum frequency rating for these N Type connectors?

A: Both parts are rated for maximum frequency operation up to 18 GHz, suitable for RF applications in this frequency range.

Q: How many mating cycles are these connectors rated for?

A: Both RFNA4PCCD and RFNA4PGID are rated for 500 mating cycles, defining the expected connector engagement and disengagement cycles.

Q: What packaging format is available for these parts?

A: Both parts are supplied in Bulk packaging format.

Request Quote (Ships tomorrow)