The Vicor MI-J7R-IZ is an isolated DC-DC converter designed for ITE (Commercial) applications, offering a single 7.5V output at up to 3.33A, with a wide input voltage range of 100V to 310V. This model is rated at 25W and incorporates protection features including OCP, OTP, and OVP. The MI-J7R-IZ is now listed as obsolete, necessitating the identification of directly compatible substitute models for design continuity and maintenance.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | REACH Status | Product Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MI-J7R-IZ | Isolated Module | 1 | 100V | 310V | 7.5V | 3.33A | 25 W | 3 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP | -40°C ~ 85°C | 90% | Through Hole | 9-DIP Module | 2.40" L x 2.28" W x 0.50" H | RoHS non-compliant | REACH Unaffected | Obsolete |
Substitute Part Grouping Explanation
Substitute part grouping for the MI-J7R-IZ is determined strictly by matching the electrical, mechanical, and environmental specifications. The key parameters for evaluating direct interchangeability are: output voltage, output current, input voltage range, isolation voltage, protection features, operating temperature range, efficiency, mounting type, size/dimension, and package/case. Compliance data and product status are included for regulatory alignment and component lifecycle management.
Parameter Comparison
| Manufacturer Part Number | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | REACH Status | Product Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MI-J7R-IZ | Isolated Module | 1 | 100V | 310V | 7.5V | 3.33A | 25 W | 3 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP | -40°C ~ 85°C | 90% | Through Hole | 9-DIP Module | 2.40" L x 2.28" W x 0.50" H | RoHS non-compliant | REACH Unaffected | Obsolete |
| MI-J7R-IZ-F1 | Isolated Module | 1 | 100V | 310V | 7.5V | 3.33A | 25 W | 3 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP | -40°C ~ 85°C | 90% | Through Hole | 9-DIP Module | 2.40" L x 2.28" W x 0.50" H | RoHS non-compliant | REACH Unaffected | Active |
Engineering Selection Recommendations
The MI-J7R-IZ is obsolete, while the MI-J7R-IZ-F1 maintains active production status. Both parts have identical core electrical and mechanical specifications, including output voltage, current, power rating, isolation voltage, features, mounting, and dimensions. RoHS non-compliance and REACH unaffected status are consistent across both models. Selection should be made based on current availability and lifecycle status, prioritizing the active MI-J7R-IZ-F1 for future design maintenance.
Frequently Asked Questions (FAQ)
Q1: What parameters are essential for selecting a substitute for the MI-J7R-IZ?
A1: Essential parameters include output voltage, output current, input voltage range, isolation voltage, protection features, efficiency, operating temperature, mounting type, package/case, size/dimension, and compliance characteristics.
Q2: Is the MI-J7R-IZ-F1 compatible in terms of physical and electrical characteristics?
A2: The MI-J7R-IZ-F1 matches all critical physical and electrical characteristics, including form factor and protection features.
Q3: Do the RoHS and REACH statuses impact compatibility?
A3: Both parts are RoHS non-compliant and REACH unaffected, which does not impact direct technical compatibility but may affect selection in regulated environments.
Q4: Are mounting and package types equivalent?
A4: Both MI-J7R-IZ and MI-J7R-IZ-F1 utilize the 9-DIP Module package and through-hole mounting, ensuring mechanical interchangeability.
Q5: Does the operating temperature range differ between the original and substitute parts?
A5: Both parts are rated for an operating temperature range of -40°C to 85°C, supporting equivalent environmental performance.
Q6: Can the MI-J7R-IZ-F1 be used as a drop-in replacement for the MI-J7R-IZ?
A6: All specified parameters are identical, permitting direct substitution in applicable assemblies requiring these specifications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts