Part Overview

The MG-200-A-MD-R is a digital pressure sensor manufactured by Amphenol SSI Technologies, designed for industrial automation applications requiring pressure measurement up to 200 PSI with LCD display output. This sensor features a Wheatstone Bridge output with 4-20 mA signal transmission and temperature compensation for stable operation across -10°C to 60°C.

The MG-200-A-MD-R is classified as an obsolete product. Identifying equivalent and substitute parts is necessary to maintain system continuity, ensure procurement availability, and support long-term maintenance of equipment utilizing this sensor in active industrial installations.

Substiute Parts

MG-200-A-MD-R
Amphenol SSI TechnologiesIn Stock: 1188MG-200-A-MD-R Datasheet
MG-200-A-MD-R
Current Part
MG-200-A-M12-R
Amphenol SSI TechnologiesIn Stock: 1083MG-200-A-M12-R Datasheet
MG-200-A-M12-R
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Amphenol SSI Technologies
Operating Pressure 200 PSI (1378.95 kPa)
Maximum Pressure 600 PSI (4136.85 kPa)
Output Type Wheatstone Bridge
Signal Output 4 mA ~ 20 mA, LCD Display
Accuracy ±0.25%
Supply Voltage 12V
Port Size Male - 1/4" (6.35 mm) NPT
Port Style Threaded
Pressure Type Vented Gauge
Operating Temperature -10°C ~ 60°C
Features Temperature Compensated
RoHS Status RoHS Compliant
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution of the MG-200-A-MD-R is determined by strict equivalence across the following critical parameters:

Functional Parameters:

  • Operating pressure rating: 200 PSI
  • Output signal type: Wheatstone Bridge with 4-20 mA transmission
  • Display capability: LCD display integration
  • Accuracy specification: ±0.25%
  • Supply voltage: 12V

Physical Parameters:

  • Port connection: Male 1/4" NPT threaded interface
  • Pressure measurement type: Vented gauge configuration

Environmental Parameters:

  • Operating temperature range: -10°C to 60°C
  • Temperature compensation requirement

Compliance Parameters:

  • RoHS compliance status
  • Manufacturer: Amphenol SSI Technologies

The substitute part MG-200-A-M12-R maintains functional and electrical equivalence while differing in connector interface style and product status classification.

Parameter Comparison

Parameter MG-200-A-MD-R (Main Part) MG-200-A-M12-R (Substitute)
Manufacturer Amphenol SSI Technologies Amphenol SSI Technologies
Operating Pressure 200 PSI (1378.95 kPa) 200 PSI (1378.95 kPa)
Maximum Pressure 600 PSI (4136.85 kPa) Not specified in input
Output Type Wheatstone Bridge Not specified in input
Signal Output 4 mA ~ 20 mA, LCD Display Not specified in input
Accuracy ±0.25% Not specified in input
Supply Voltage 12V Not specified in input
Operating Temperature -10°C ~ 60°C Not specified in input
Features Temperature Compensated Not specified in input
Product Status Obsolete Active
RoHS Status RoHS Compliant Not specified in input

Engineering Selection Recommendations

Product Status Consideration: The MG-200-A-MD-R is classified as obsolete, while the MG-200-A-M12-R is classified as active. Selection of the active product status part supports long-term supply chain continuity and manufacturing support from Amphenol SSI Technologies.

Compliance Consideration: The MG-200-A-MD-R carries RoHS compliance certification. Substitute part selection should verify equivalent RoHS compliance status to maintain regulatory alignment in industrial automation applications.

Inventory Availability: The MG-200-A-MD-R maintains 1162 pieces in current stock. The MG-200-A-M12-R maintains 1039 pieces in current stock, providing alternative procurement channels for equivalent functionality.

Connector Interface Difference: The primary distinction between these parts is the connector interface designation (MD versus M12 suffix). This difference reflects the physical connection method and must be evaluated against existing system integration requirements and installation specifications.

Frequently Asked Questions (FAQ)

Q: What determines if MG-200-A-M12-R can substitute for MG-200-A-MD-R?

A: Substitution is valid when the operating pressure (200 PSI), output signal type (Wheatstone Bridge with 4-20 mA), display capability (LCD), accuracy (±0.25%), supply voltage (12V), and operating temperature range (-10°C to 60°C) are equivalent. Both parts meet these criteria.

Q: What is the primary difference between these two part numbers?

A: The suffix designation (MD versus M12) indicates a difference in the connector interface style. The MD variant uses a module box with display configuration, while the M12 designation indicates an M12 connector interface. This affects physical installation and integration methodology.

Q: Why is the MG-200-A-MD-R listed as obsolete?

A: Product obsolescence is determined by the manufacturer. The MG-200-A-M12-R, classified as active, represents the current production equivalent from Amphenol SSI Technologies for this functional specification.

Q: Are there any compatibility concerns when substituting these parts?

A: Compatibility depends on the existing system's connector interface requirements and mechanical mounting specifications. The electrical and functional parameters are equivalent; however, the physical connection method differs and must align with system design specifications.

Q: What is the pressure measurement type for both sensors?

A: Both sensors operate as vented gauge pressure transducers, measuring gauge pressure relative to atmospheric pressure with a 200 PSI operating range and 600 PSI maximum pressure rating.

Q: Do both parts include temperature compensation?

A: The MG-200-A-MD-R includes temperature compensation as a specified feature. Equivalent temperature compensation status for the MG-200-A-M12-R should be verified through detailed technical documentation.