The MAX188DCAP is a 12-bit Analog-to-Digital Converter (ADC) manufactured by Analog Devices Inc./Maxim Integrated, designed for data acquisition applications requiring SAR (Successive Approximation Register) architecture with configurable input channels. The device operates with external voltage references and supports both differential and single-ended input configurations through an integrated multiplexer and sample-and-hold circuit.
The MAX188DCAP is classified as obsolete, which necessitates identification of functionally equivalent alternatives for new designs or component replenishment. Substitute parts must maintain compatibility across critical electrical parameters, package specifications, and interface protocols to ensure seamless integration into existing or legacy systems.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | MAX188DCAP |
| Manufacturer | Analog Devices Inc./Maxim Integrated |
| Resolution (Bits) | 12 |
| Sampling Rate | 133 kSPS |
| Number of Input Channels | 4, 8 |
| Input Type | Differential, Single Ended |
| Data Interface | SPI |
| Architecture | SAR |
| Reference Type | External |
| Voltage Supply (Analog) | ±5V, 5V |
| Voltage Supply (Digital) | ±5V, 5V |
| Operating Temperature Range | 0°C to 70°C |
| Package Type | 20-SSOP (0.209", 5.30mm Width) |
| Mounting Type | Surface Mount |
| Product Status | Obsolete |
| RoHS Status | RoHS Non-Compliant |
| MSL Rating | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution eligibility for the MAX188DCAP is determined by strict alignment across the following critical parameters:
Resolution and Sampling Rate: The substitute part must maintain 12-bit resolution and 133 kSPS sampling rate to preserve signal fidelity and timing characteristics in data acquisition circuits.
Input Configuration: The substitute must support both differential and single-ended input modes with equivalent channel count (4 or 8 channels) to maintain signal routing flexibility.
Data Interface Protocol: The substitute must support SPI communication protocol to ensure compatibility with existing microcontroller and FPGA interfaces without firmware modification.
Package and Pinout: The substitute must use the 20-SSOP package with identical pin assignments to enable direct PCB-level replacement without layout redesign.
Voltage Supply Requirements: The substitute must operate with ±5V and 5V supply rails to match existing power distribution infrastructure.
Architecture: The substitute must employ SAR architecture with external reference capability to maintain conversion methodology and reference flexibility.
Based on these criteria, the MAX188DCAP+ qualifies as a direct substitute, as it maintains all critical electrical and mechanical parameters while offering improved product status and compliance certifications.
Parameter Comparison
| Parameter | MAX188DCAP (Main Part) | MAX188DCAP+ (Substitute) | Compatibility |
|---|---|---|---|
| Manufacturer | Analog Devices Inc./Maxim Integrated | Analog Devices Inc./Maxim Integrated | Identical |
| Resolution (Bits) | 12 | 12 | Identical |
| Sampling Rate (kSPS) | 133 | 133 | Identical |
| Number of Channels | 4, 8 | 8 | Compatible |
| Data Interface | SPI | MICROWIRE™, QSPI™, Serial, SPI™ | Compatible (SPI included) |
| Voltage Supply (Analog) | ±5V, 5V | ±5V | Compatible |
| Voltage Supply (Digital) | ±5V, 5V | ±5V | Compatible |
| Operating Temperature | 0°C to 70°C | 0°C to 70°C | Identical |
| Package Type | 20-SSOP | 20-SSOP | Identical |
| Mounting Type | Surface Mount | Surface Mount | Identical |
| Product Status | Obsolete | Active | Improved |
| RoHS Status | RoHS Non-Compliant | RoHS3 Compliant | Improved |
| MSL Rating | 1 (Unlimited) | 1 (Unlimited) | Identical |
Engineering Selection Recommendations
The MAX188DCAP+ is the qualified substitute for the obsolete MAX188DCAP based on the following engineering criteria:
Product Status Alignment: The MAX188DCAP+ maintains active product status with ongoing manufacturer support, ensuring long-term component availability and technical documentation access compared to the obsolete MAX188DCAP.
Regulatory Compliance: The MAX188DCAP+ achieves RoHS3 compliance, meeting current environmental and hazardous substance restrictions. The original MAX188DCAP does not meet RoHS requirements, which may present procurement and regulatory challenges in applications subject to RoHS directives.
Electrical Parameter Equivalence: Both parts maintain identical 12-bit resolution, 133 kSPS sampling rate, and ±5V supply voltage specifications, ensuring functional interchangeability in data acquisition circuits.
Interface Protocol Compatibility: The MAX188DCAP+ supports SPI protocol alongside additional serial interface options (MICROWIRE™, QSPI™), providing backward compatibility with existing SPI-based system designs.
Package and Thermal Characteristics: Both parts use identical 20-SSOP surface-mount packaging with MSL 1 rating, enabling direct PCB replacement without layout modification or thermal management redesign.
Frequently Asked Questions (FAQ)
Q: Can the MAX188DCAP+ be used as a direct replacement for the MAX188DCAP in existing designs?
A: Yes. The MAX188DCAP+ maintains identical package geometry (20-SSOP), pin configuration, resolution (12-bit), sampling rate (133 kSPS), and SPI interface protocol. Direct PCB-level substitution is possible without circuit redesign.
Q: What are the key differences between MAX188DCAP and MAX188DCAP+?
A: The primary differences are product status and compliance. The MAX188DCAP+ is an active product with RoHS3 compliance, while the MAX188DCAP is obsolete and RoHS non-compliant. Both maintain identical electrical specifications and package type.
Q: Does the MAX188DCAP+ support the same input channel configurations?
A: The MAX188DCAP+ supports 8-channel configuration with differential and single-ended input modes. The original MAX188DCAP supports both 4 and 8-channel variants. The 8-channel MAX188DCAP+ is compatible with designs using either configuration.
Q: Are there any firmware or software modifications required when switching from MAX188DCAP to MAX188DCAP+?
A: No firmware modifications are required. Both parts implement identical SPI protocol timing and command structures. The MAX188DCAP+ supports additional serial interface options (MICROWIRE™, QSPI™), but SPI operation remains unchanged.
Q: What is the moisture sensitivity level for both parts?
A: Both the MAX188DCAP and MAX188DCAP+ carry MSL 1 (Unlimited) rating, indicating no moisture sensitivity restrictions during storage or handling.
Q: Are the supply voltage requirements identical?
A: Both parts operate with ±5V dual supply or single 5V supply configurations. The MAX188DCAP+ is specified for ±5V operation. Verify your specific application voltage rails match these requirements.
Q: Can the MAX188DCAP+ be used in temperature-critical applications?
A: Both parts operate across the 0°C to 70°C temperature range. For applications requiring extended temperature operation, alternative ADC families with wider temperature specifications should be evaluated.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts