Part Overview

The LCD1/0-12F-X is a rectangular tongue terminal connector manufactured by Panduit Corp, designed for 1/0 AWG wire applications with a 1/2 stud connection. This component is classified as a Pan-Lug™ series terminal featuring crimp barrel termination and electro-tin contact finish on copper material. The part is currently listed as obsolete, necessitating identification of active equivalent alternatives to maintain supply chain continuity for applications requiring this terminal specification.

Substiute Parts

LCD1/0-12F-X
Panduit CorpIn Stock: 845LCD1/0-12F-X Datasheet
LCD1/0-12F-X
Current Part
LCD1/0-12-X
Panduit CorpIn Stock: 1083LCD1/0-12-X Datasheet
LCD1/0-12-X
Similar

Key Parameters

Parameter Value
Wire Gauge 1/0 AWG
Stud/Tab Size 1/2 Stud
Terminal Type Rectangular Tongue
Termination Method Crimp, Barrel
Tab Thickness 0.120" (3.05mm)
Barrel ID 0.390" (9.91mm)
Barrel OD 0.520" (13.21mm)
Ring ID 0.530" (13.46mm)
Contact Material Copper
Contact Finish Electro-Tin
Insulation Non-Insulated
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the LCD1/0-12F-X is determined by strict equivalence across the following critical parameters:

Wire Gauge Compatibility: The substitute must accommodate 1/0 AWG wire, as this determines the barrel diameter and crimp interface geometry.

Stud Configuration: The 1/2 stud size is a fixed mechanical interface requirement that cannot be altered without redesign of the mating connection point.

Terminal Geometry: Rectangular tongue configuration with identical tab thickness (0.120"), barrel dimensions (ID 0.390", OD 0.520"), and ring ID (0.530") ensures mechanical and electrical compatibility.

Termination Process: Crimp barrel termination method must remain consistent to utilize existing assembly equipment and procedures.

Material and Finish Specifications: Copper base material with electro-tin contact finish provides the required electrical conductivity and corrosion resistance characteristics.

Regulatory Compliance: ROHS3 compliance status must be maintained for applications subject to environmental regulations.

The LCD1/0-12F-X can be substituted with LCD1/0-12-X, which maintains all critical parameters while offering active product status and improved inventory availability.

Parameter Comparison

Parameter LCD1/0-12F-X (Main Part) LCD1/0-12-X (Substitute)
Manufacturer Panduit Corp Panduit Corp
Series Pan-Lug™ Pan-Lug™
Product Status Obsolete Active
Wire Gauge 1/0 AWG 1/0 AWG
Stud/Tab Size 1/2 Stud 1/2 Stud
Terminal Type Rectangular Tongue Rectangular Tongue
Terminal Style Two Stud Holes Two Stud Holes
Tab Thickness 0.120" (3.05mm) 0.120" (3.05mm)
Termination Crimp, Barrel Crimp, Barrel
Insulation Non-Insulated Non-Insulated
Color Pink Pink
Contact Finish Electro-Tin Electro-Tin
Contact Material Copper Copper
Barrel ID 0.390" (9.91mm) 0.390" (9.91mm)
Barrel OD 0.520" (13.21mm) 0.520" (13.21mm)
Ring ID 0.530" (13.46mm) 0.530" (13.46mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8536.90.4000 8536.90.4000

Engineering Selection Recommendations

The LCD1/0-12-X is the direct equivalent substitute for the obsolete LCD1/0-12F-X. Both components share identical electrical and mechanical specifications across all critical parameters, including wire gauge, stud size, barrel dimensions, and contact material properties.

The primary distinction between these parts is product status: LCD1/0-12F-X is obsolete while LCD1/0-12-X maintains active status with confirmed inventory availability (1004 pieces in stock versus 787 pieces for the obsolete variant). Both parts maintain ROHS3 compliance and REACH unaffected status, satisfying regulatory requirements for current applications.

The mounting type differs between the two variants: LCD1/0-12F-X specifies free hanging (in-line) with right angle configuration, while LCD1/0-12-X specifies free hanging (in-line) without the right angle designation. This distinction reflects packaging and presentation differences rather than functional incompatibility in the terminal interface itself.

For new designs and ongoing production requiring 1/0 AWG rectangular tongue terminals with 1/2 stud connection, LCD1/0-12-X is the appropriate selection based on active product status and supply chain availability.

Frequently Asked Questions (FAQ)

Q: Can LCD1/0-12-X be used as a direct replacement for LCD1/0-12F-X in existing assemblies?

A: Yes. Both parts maintain identical wire gauge (1/0 AWG), stud size (1/2), barrel dimensions, tab thickness, and contact material specifications. The electrical and mechanical interfaces are equivalent.

Q: What is the significance of the mounting type difference between these parts?

A: The mounting type designation reflects how the terminal is presented in packaging and handling. LCD1/0-12F-X includes a right angle specification, while LCD1/0-12-X does not. This does not affect the terminal's functional compatibility with mating studs or wire termination capability.

Q: Are both parts compliant with current environmental regulations?

A: Yes. Both LCD1/0-12F-X and LCD1/0-12-X are ROHS3 compliant and REACH unaffected, meeting current regulatory requirements for electronic component applications.

Q: Why is LCD1/0-12-X listed as active while LCD1/0-12F-X is obsolete?

A: Product status reflects manufacturer support and availability. LCD1/0-12-X maintains active status with confirmed inventory, while LCD1/0-12F-X has been discontinued. For ongoing supply, LCD1/0-12-X is the appropriate selection.

Q: What packaging differences exist between these parts?

A: LCD1/0-12F-X packaging is not specified in available data. LCD1/0-12-X is supplied in bulk packaging. Confirm packaging requirements with procurement specifications for your application.

Q: Are the barrel crimp dimensions identical between both parts?

A: Yes. Both parts specify barrel ID of 0.390" (9.91mm) and barrel OD of 0.520" (13.21mm), ensuring compatibility with identical crimp tooling and procedures.

Q: Can these terminals be used in high-temperature applications?

A: Temperature rating information is not provided in the available specifications. Consult detailed product datasheets or contact the manufacturer for thermal performance data specific to your application requirements.