JCK6048S12 Equivalent & Substitute Parts Reference

Part Overview

The JCK6048S12 is an isolated DC-DC converter module produced by XP Power, designed for ITE (Commercial) applications. It features a single 12V output at up to 5A, with an input voltage range of 36V to 75V and a maximum power output of 60W. The product is currently active and available in tube packaging as an 8-DIP module for through-hole mounting. Identifying equivalent or substitute models is often necessary for supply chain continuity, lead time reduction, or dual-sourcing, ensuring that systems maintain validated electrical performance and regulatory compliance.

Substiute Parts

JCK6048S12
XP PowerIn Stock: 916JCK6048S12 Datasheet
JCK6048S12
Current Part
SKA60C-12
MEAN WELL USA Inc.In Stock: 946SKA60C-12 Datasheet
SKA60C-12
MFR Recommended

Key Parameters

ParameterValue
Manufacturer Part NumberJCK6048S12
ManufacturerXP Power
DescriptionDC DC CONVERTER 12V 60W
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)36V
Voltage - Input (Max)75V
Voltage - Output 112V
Current - Output (Max)5A
Power (Watts)60 W
Voltage - Isolation1.6 kV
ApplicationsITE (Commercial)
FeaturesRemote On/Off, OCP, OVP, SCP, UVLO
Operating Temperature-40°C ~ 100°C
Efficiency91%
Mounting TypeThrough Hole
Package / Case8-DIP Module
Size / Dimension2.00" L x 2.00" W x 0.40" H (50.8mm x 50.8mm x 10.2mm)
RoHS StatusROHS3 Compliant
Moisture Sensitivity Level (MSL)1 (Unlimited)
ECCNEAR99
Inventory832 Pcs New Original In Stock
Product StatusActive

Substitute Part Grouping Explanation

Substitute parts for the JCK6048S12 are grouped strictly according to key matching electrical, mechanical, and compliance parameters. The following parameters are considered fundamental for equivalence in DC-DC converter module selection:

  • Input voltage range (36V to 75V)
  • Output voltage (12V)
  • Output current (5A)
  • Output power (60W)
  • Isolation voltage
  • Mounting type and package dimensions
  • Compliance status (RoHS, MSL)
  • Features (Remote On/Off, OCP, OVP, SCP)
  • Application class (ITE/Commercial)

Only parts matching this complete set of parameters are listed as substitutes.

Parameter Comparison

Parameter JCK6048S12 (XP Power) SKA60C-12 (MEAN WELL USA Inc.)
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 36V 36V
Voltage - Input (Max) 75V 75V
Voltage - Output 1 12V 12V
Current - Output (Max) 5A 5A
Power (Watts) 60 W 60 W
Voltage - Isolation 1.6 kV 1.5 kV
Applications ITE (Commercial) ITE (Commercial)
Features Remote On/Off, OCP, OVP, SCP, UVLO Remote On/Off, OCP, OVP, SCP
Operating Temperature -40°C ~ 100°C -40°C ~ 70°C (With Derating)
Efficiency 91% 92%
Mounting Type Through Hole Through Hole
Package / Case 8-DIP Module 8-DIP Module
Size / Dimension 2.00" x 2.00" x 0.40" (50.8mm x 50.8mm x 10.2mm) 2.00" x 2.00" x 0.43" (50.8mm x 50.8mm x 11.0mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
ECCN EAR99 EAR99
Inventory 832 Pcs New Original In Stock 872 Pcs New Original In Stock
Product Status Active Active

Engineering Selection Recommendations

Both JCK6048S12 and SKA60C-12 are active products and are ROHS3 compliant with an MSL rating of 1 (Unlimited). Both models are classified under ECCN EAR99. Inventory quantities are available for both parts, and both are packaged in an 8-DIP module suitable for through-hole mounting. Substitute selection can be made based solely on these product status and compliance attributes.

Frequently Asked Questions (FAQ)

Q1: Which parameters must be strictly matched when substituting DC-DC converter modules?
A1: Substitution requires identical input voltage range, output voltage, output current, isolation voltage, mounting type, package, and compliance status.

Q2: Can JCK6048S12 and SKA60C-12 be used interchangeably in PCB layouts?
A2: Both are supplied in 8-DIP modules designed for through-hole mounting with similar physical dimensions.

Q3: Do both parts support the same safety and protection features?
A3: Both provide Remote On/Off, OCP, OVP, and SCP features; UVLO is specified only for JCK6048S12.

Q4: What environmental and compliance standards are met by both parts?
A4: Both parts are ROHS3 compliant and have an MSL of 1 (Unlimited), with ECCN classification EAR99.

Q5: Are there significant differences in electrical performance between these substitutes?
A5: Both modules operate with the same input and output specifications and have comparable efficiency and isolation voltages as detailed in the parameter comparison table.

Request Quote (Ships tomorrow)