Request Quote
(Ships tomorrow)
IXKC19N60C5 N-Channel 600V 19A MOSFET Equivalent & Substitute Parts
Part Overview
The IXKC19N60C5 is an N-Channel 600V 19A MOSFET manufactured by IXYS in the CoolMOS™ series, housed in the ISOPLUS220™ through-hole package. This device is classified as obsolete, necessitating identification of functionally equivalent alternatives for ongoing design support and procurement. The part operates across a temperature range of -55°C to 150°C and is RoHS3 compliant with unlimited moisture sensitivity rating.
Substiute Parts
Key Parameters
| Parameter | Value | Unit |
|---|---|---|
| Drain to Source Voltage (Vdss) | 600 | V |
| Continuous Drain Current (Id) @ 25°C | 19 | A |
| Drive Voltage (Max Rds On) | 10 | V |
| Rds On (Max) @ Id, Vgs | 125 mOhm @ 16A, 10V | mOhm |
| Gate Threshold Voltage Vgs(th) (Max) | 3.5 | V @ 1.1mA |
| Gate Charge (Qg) (Max) @ Vgs | 70 | nC @ 10V |
| Input Capacitance (Ciss) (Max) @ Vds | 2500 | pF @ 100V |
| Maximum Gate Voltage (Vgs) | ±20 | V |
| Operating Temperature Range | -55 to 150 | °C (TJ) |
| Mounting Type | Through Hole | — |
| Package | ISOPLUS220™ | — |
| RoHS Status | ROHS3 Compliant | — |
Substitute Part Grouping Explanation
Substitution of the IXKC19N60C5 is determined by strict alignment of electrical and mechanical parameters. The critical substitution criteria are:
Electrical Compatibility Requirements:
- Drain to Source Voltage (Vdss) must equal or exceed 600V
- Continuous Drain Current (Id) must meet or exceed 19A at 25°C
- Drive Voltage (Max Rds On) must be 10V
- Gate Threshold Voltage (Vgs(th)) must be compatible with control circuitry
- Maximum Gate Voltage (Vgs) must accommodate ±20V or greater
- Operating temperature range must support -55°C to 150°C or equivalent upper limit
Mechanical Compatibility Requirements:
- Mounting type must be through-hole
- Package must be physically compatible with ISOPLUS220™ or equivalent footprint dimensions
- Pin configuration must support direct substitution
Compliance Requirements:
- RoHS3 compliance mandatory
- Moisture Sensitivity Level (MSL) of 1 (Unlimited) required
Substitute parts are grouped by their ability to meet these criteria while maintaining functional equivalence in the target application circuit.
Parameter Comparison
| Parameter | IXKC19N60C5 | IPA60R125C6XKSA1 | R6030ENX | R6030KNX | R6030KNXC7 | STF28NM60ND | STF34NM60ND |
|---|---|---|---|---|---|---|---|
| Manufacturer | IXYS | Infineon Technologies | Rohm Semiconductor | Rohm Semiconductor | Rohm Semiconductor | STMicroelectronics | STMicroelectronics |
| Vdss (V) | 600 | 600 | 600 | 600 | 600 | 600 | 600 |
| Id @ 25°C (A) | 19 | 30 | 30 | 30 | 30 | 23 | 29 |
| Drive Voltage (V) | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
| Rds On (Max) @ Id, Vgs (mOhm) | 125 @ 16A, 10V | 125 @ 14.5A, 10V | 130 @ 14.5A, 10V | 130 @ 14.5A, 10V | 130 @ 14.5A, 10V | 150 @ 11.5A, 10V | 110 @ 14.5A, 10V |
| Vgs(th) (Max) (V) | 3.5 @ 1.1mA | 3.5 @ 960µA | 4 @ 1mA | 5 @ 1mA | 5 @ 1mA | 5 @ 250µA | 5 @ 250µA |
| Gate Charge Qg (Max) (nC) | 70 @ 10V | 96 @ 10V | 85 @ 10V | 56 @ 10V | 56 @ 10V | 62.5 @ 10V | 80.4 @ 10V |
| Ciss (Max) (pF) | 2500 @ 100V | 2127 @ 100V | 2100 @ 25V | 2350 @ 25V | 2350 @ 25V | 2090 @ 100V | 2785 @ 50V |
| Vgs (Max) (V) | ±20 | ±20 | ±30 | ±20 | ±20 | ±25 | ±25 |
| Operating Temperature (°C) | -55 to 150 | -55 to 150 | to 150 | -55 to 150 | -55 to 150 | to 150 | to 150 |
| Mounting Type | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole |
| Package | ISOPLUS220™ | TO-220-3 Full Pack | TO-220-3 Full Pack | TO-220-3 Full Pack | TO-220-3 Full Pack | TO-220-3 Full Pack | TO-220-3 Full Pack |
| Product Status | Obsolete | Not For New Designs | Active | Active | Active | Not For New Designs | Active |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
Engineering Selection Recommendations
Primary Substitutes (Active Product Status):
The R6030KNX and R6030KNXC7 from Rohm Semiconductor are the preferred substitutes for the IXKC19N60C5. Both parts maintain active product status, ensuring long-term availability and supply chain stability. These devices are electrically equivalent with 600V Vdss, 30A continuous drain current, and 10V drive voltage. The R6030KNXC7 is supplied in tube packaging, while R6030KNX is supplied in bulk. Both support the full -55°C to 150°C operating temperature range and are RoHS3 compliant. The TO-220FM package is mechanically compatible with standard through-hole PCB layouts.
Secondary Substitutes (Active Product Status):
The STF34NM60ND from STMicroelectronics (FDmesh™ II series) is an active product offering 600V Vdss and 29A continuous drain current. This device provides superior on-resistance characteristics (110 mOhm) compared to the main part and maintains RoHS3 compliance. However, the operating temperature range extends only to 150°C without specified lower limit documentation.
The R6030ENX from Rohm Semiconductor is active but provides only 150°C upper temperature limit without documented lower limit, making it suitable for applications not requiring -55°C operation.
Legacy Substitutes (Not For New Designs):
The IPA60R125C6XKSA1 from Infineon Technologies and STF28NM60ND from STMicroelectronics carry "Not For New Designs" status. While electrically compatible, these parts should not be selected for new circuit development due to product lifecycle constraints.
Package Consideration:
The IXKC19N60C5 uses the ISOPLUS220™ package. Substitute parts employ the TO-220-3 Full Pack configuration. Physical footprint verification is required to confirm PCB compatibility, as these packages may have different lead spacing or mounting hole dimensions despite both being through-hole technologies.
Frequently Asked Questions (FAQ)
Q: Can the R6030KNX directly replace the IXKC19N60C5 without circuit modification?
A: The R6030KNX meets all critical electrical parameters: 600V Vdss, 30A continuous drain current (exceeding the 19A requirement), 10V drive voltage, and compatible gate voltage ratings. However, package differences between ISOPLUS220™ and TO-220FM require PCB footprint verification. Lead spacing, mounting hole diameter, and thermal pad dimensions must be confirmed before direct substitution.
Q: What is the significance of the "Not For New Designs" status on the IPA60R125C6XKSA1 and STF28NM60ND?
A: "Not For New Designs" indicates the manufacturer has discontinued active development and support for these parts. While functionally suitable, these devices should not be incorporated into new circuit designs due to uncertain long-term availability and potential supply discontinuation. Existing designs using these parts may continue operation, but new applications should select active-status alternatives.
Q: How do the Rohm R6030 variants (R6030ENX, R6030KNX, R6030KNXC7) differ?
A: R6030ENX and R6030KNX are electrically identical (600V, 30A, 130 mOhm Rds On) but differ in packaging: R6030ENX is supplied in bulk, while R6030KNX is supplied in bulk. R6030KNXC7 is the tube-packaged variant of R6030KNX with identical electrical specifications. Selection depends on procurement quantity requirements and packaging preferences. All three are RoHS3 compliant and active products.
Q: Why do substitute parts show higher continuous drain current (30A) than the original (19A)?
A: Higher current ratings indicate superior thermal and electrical performance characteristics. A 30A-rated device can safely operate at 19A with lower junction temperature rise and improved reliability margins. This represents a performance upgrade rather than a limitation. However, gate charge and input capacitance may differ, requiring verification of gate drive circuit capability.
Q: Is the operating temperature range difference between parts critical?
A: The IXKC19N60C5 specifies -55°C to 150°C. Some substitutes (R6030ENX, STF28NM60ND, STF34NM60ND) document only the upper limit of 150°C without explicit lower limit specification. For applications requiring operation below 0°C, the R6030KNX, R6030KNXC7, and IPA60R125C6XKSA1 are preferred due to documented -55°C minimum ratings.
Q: What packaging considerations apply when substituting from ISOPLUS220™ to TO-220FM?
A: Both are through-hole packages, but physical dimensions differ. ISOPLUS220™ and TO-220FM have different lead spacing and mounting configurations. PCB layout modifications may be necessary, including potential changes to mounting hole positions and thermal pad design. Mechanical drawings from both manufacturers must be compared before committing to substitution.
Q: Are all substitute parts RoHS3 compliant?
A: Yes. All listed substitute parts carry RoHS3 Compliant status with REACH Unaffected designation and EAR99 ECCN classification, matching the compliance profile of the IXKC19N60C5. Moisture Sensitivity Level (MSL) is 1 (Unlimited) across all parts, indicating no special moisture handling requirements.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts