HPB100RTTA Barometer Equivalent & Substitute Parts

Part Overview

The HPB100RTTA is an absolute pressure barometer sensor manufactured by Honeywell Aerospace, designed for industrial automation applications. This component features TTL output, operates across a 7.25PSI to 17.4PSI pressure range, and maintains accuracy of ±0.012PSI. The HPB100RTTA is classified as obsolete, making identification of equivalent substitute parts essential for system maintenance, repair, and redesign applications where continued component availability is required.

Substiute Parts

HPB100RTTA
Honeywell AerospaceIn Stock: 927HPB100RTTA Datasheet
HPB100RTTA
Current Part
HPB200RTTA
Honeywell AerospaceIn Stock: 906HPB200RTTA Datasheet
HPB200RTTA
Direct

Key Parameters

Parameter Value
Manufacturer Honeywell Aerospace
Description Barometer Sensor, Transducer
Pressure Type Absolute
Operating Pressure Range 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa)
Output Type TTL
Accuracy ±0.012PSI (±0.08kPa)
Voltage Supply 6V ~ 26V
Port Size Male - 0.13" (3.18mm) Tube
Port Style Barbed
Termination Style Connector
Operating Temperature -40°C ~ 85°C
Package / Case Module Cube
RoHS Status RoHS non-compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the HPB100RTTA is determined by strict equivalence across the following critical parameters:

Pressure Specifications: Operating pressure range must match 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa) with absolute pressure type classification.

Electrical Interface: Output type must be TTL. Voltage supply range must encompass 6V ~ 26V operation.

Mechanical Interface: Port size must be Male - 0.13" (3.18mm) Tube with barbed port style. Termination must be connector-based.

Environmental Compliance: Operating temperature range must support -40°C ~ 85°C. Moisture sensitivity level must be 1 (Unlimited).

Physical Form Factor: Package must be Module Cube configuration.

The HPB200RTTA meets all substitution criteria while offering improved accuracy specification (±0.006PSI versus ±0.012PSI) and active product status, making it a direct functional equivalent.

Parameter Comparison

Parameter HPB100RTTA (Main Part) HPB200RTTA (Substitute) Compatibility
Manufacturer Honeywell Aerospace Honeywell Aerospace Match
Pressure Type Absolute Absolute Match
Operating Pressure Range 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa) 7.25PSI ~ 17.4PSI (50kPa ~ 120kPa) Match
Output Type TTL TTL Match
Accuracy ±0.012PSI (±0.08kPa) ±0.006PSI (±0.04kPa) Substitute Superior
Voltage Supply 6V ~ 26V 6V ~ 26V Match
Port Size Male - 0.13" (3.18mm) Tube Male - 0.13" (3.18mm) Tube Match
Port Style Barbed Barbed Match
Termination Style Connector Connector Match
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C Match
Package / Case Module Cube Module Cube Match
RoHS Status RoHS non-compliant RoHS non-compliant Match
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited) Match
Product Status Obsolete Active Substitute Current

Engineering Selection Recommendations

The HPB200RTTA is the direct substitute for the HPB100RTTA based on complete parameter equivalence across all specified electrical, mechanical, and environmental criteria. The HPB200RTTA provides the following advantages:

Product Status: The HPB200RTTA maintains active product status with current manufacturing availability, whereas the HPB100RTTA is classified as obsolete. This ensures long-term supply chain continuity and access to technical support.

Accuracy Enhancement: The HPB200RTTA delivers improved measurement accuracy at ±0.006PSI (±0.04kPa) compared to the HPB100RTTA at ±0.012PSI (±0.08kPa), providing superior performance within the same operational envelope.

Compliance Consistency: Both components share identical RoHS non-compliance status, ECCN classification (EAR99), and HTSUS code (9026.20.4000), ensuring regulatory and export documentation alignment.

Interface Compatibility: All electrical, pneumatic, and mechanical interfaces are identical, enabling direct replacement without circuit redesign or mechanical modification.

Frequently Asked Questions (FAQ)

Q: Can the HPB200RTTA directly replace the HPB100RTTA in existing applications?

A: Yes. The HPB200RTTA is a direct substitute meeting all electrical, mechanical, and environmental specifications of the HPB100RTTA. No circuit modifications or mechanical adaptations are required.

Q: What is the primary reason to transition from HPB100RTTA to HPB200RTTA?

A: The HPB100RTTA is obsolete with no active manufacturing. The HPB200RTTA is the current production equivalent, ensuring component availability and supply chain reliability.

Q: Are the pressure measurement ranges identical between these parts?

A: Yes. Both components operate across 7.25PSI to 17.4PSI (50kPa to 120kPa) with absolute pressure type classification.

Q: Does the HPB200RTTA require different power supply specifications?

A: No. Both components operate on identical 6V to 26V supply voltage range.

Q: Are the pneumatic port connections compatible?

A: Yes. Both components feature Male - 0.13" (3.18mm) barbed tube ports with connector termination, enabling direct pneumatic interface compatibility.

Q: What is the accuracy difference between these sensors?

A: The HPB200RTTA provides ±0.006PSI accuracy versus the HPB100RTTA at ±0.012PSI, representing a 50% improvement in measurement precision.

Q: Are there any environmental operating condition differences?

A: No. Both components maintain identical -40°C to 85°C operating temperature range and MSL 1 (Unlimited) moisture sensitivity classification.

Q: Can these parts be used interchangeably in new designs?

A: Yes. The HPB200RTTA should be specified for all new designs due to its active product status and superior accuracy performance.