HPA100X2DA Barometer Equivalent & Substitute Parts

Part Overview

The HPA100X2DA is an absolute pressure barometer sensor manufactured by Honeywell Aerospace, designed for industrial automation applications. This sensor outputs pressure data via RS-232 interface with an operating pressure range of 17.6 PSI (121.35 kPa) and operates across a temperature range of -40°C to 85°C.

The HPA100X2DA carries an obsolete product status. Identifying equivalent and substitute parts is necessary to ensure continued system functionality, maintain supply chain reliability, and support long-term industrial automation deployments where this sensor is integrated.

Substiute Parts

HPA100X2DA
Honeywell AerospaceIn Stock: 846HPA100X2DA Datasheet
HPA100X2DA
Current Part
HPA200X2DA
Honeywell AerospaceIn Stock: 1128HPA200X2DA Datasheet
HPA200X2DA
Direct

Key Parameters

Parameter Value
Manufacturer Honeywell Aerospace
Description Barometer / Sensors, Transducers
Pressure Type Absolute
Operating Pressure 17.6 PSI (121.35 kPa)
Output Type RS-232
Accuracy ±0.06%
Voltage Supply 5.5V ~ 30V
Port Size Female - 1/8" (3.18mm) Swagelok™
Port Style Threaded
Operating Temperature -40°C ~ 85°C
Package / Case Module Cube
Termination Style Connector
Product Status Obsolete
RoHS Status RoHS non-compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution eligibility for the HPA100X2DA is determined by the following critical parameters:

Mandatory Matching Parameters:

  • Pressure Type: Absolute
  • Operating Pressure: 17.6 PSI (121.35 kPa)
  • Output Type: RS-232
  • Voltage Supply Range: 5.5V ~ 30V
  • Port Size: Female - 1/8" (3.18mm) Swagelok™
  • Port Style: Threaded
  • Operating Temperature Range: -40°C ~ 85°C
  • Package / Case: Module Cube
  • Termination Style: Connector

Flexible Parameters (Allowable Variation):

  • Accuracy: May improve (lower tolerance values acceptable)
  • Product Status: Active status preferred for obsolete parts
  • Manufacturer: Honeywell Aerospace (same manufacturer maintains design compatibility)

The HPA200X2DA qualifies as a direct substitute based on identical matching of all mandatory parameters and improved accuracy specification.

Parameter Comparison

Parameter HPA100X2DA (Main Part) HPA200X2DA (Substitute) Compatibility
Manufacturer Honeywell Aerospace Honeywell Aerospace Identical
Description Barometer Barometer Identical
Pressure Type Absolute Absolute Identical
Operating Pressure 17.6 PSI (121.35 kPa) 17.6 PSI (121.35 kPa) Identical
Output Type RS-232 RS-232 Identical
Accuracy ±0.06% ±0.03% Improved
Voltage Supply 5.5V ~ 30V 5.5V ~ 30V Identical
Port Size Female - 1/8" (3.18mm) Swagelok™ Female - 1/8" (3.18mm) Swagelok™ Identical
Port Style Threaded Threaded Identical
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C Identical
Package / Case Module Cube Module Cube Identical
Termination Style Connector Connector Identical
Product Status Obsolete Active Improved

Engineering Selection Recommendations

HPA200X2DA as Primary Substitute:

The HPA200X2DA is the direct equivalent for the obsolete HPA100X2DA. This substitution is supported by:

  1. Functional Equivalence: All critical operational parameters match exactly, including pressure measurement range, output protocol, supply voltage, and physical interface specifications.

  2. Improved Accuracy: The HPA200X2DA provides ±0.03% accuracy compared to the HPA100X2DA's ±0.06%, representing a 50% improvement in measurement precision while maintaining full compatibility.

  3. Active Product Status: The HPA200X2DA is an active product, ensuring ongoing availability, technical support, and supply chain continuity.

  4. Mechanical Compatibility: Identical port configuration (Female 1/8" Swagelok™ threaded), package form factor (Module Cube), and connector termination enable direct physical replacement without system redesign.

  5. Environmental Specifications: Matching operating temperature range (-40°C to 85°C) and moisture sensitivity level (MSL 1) confirm suitability for identical deployment environments.

Compliance Consideration: Both parts maintain RoHS non-compliant status. Systems requiring RoHS compliance must evaluate alternative product lines outside this substitution group.

Frequently Asked Questions (FAQ)

Q: Can the HPA200X2DA replace the HPA100X2DA in existing installations?

A: Yes. The HPA200X2DA is a direct substitute with identical electrical and mechanical specifications. No system modifications are required for physical installation or electrical integration.

Q: What is the difference between these two barometer models?

A: The primary difference is accuracy specification. The HPA200X2DA provides ±0.03% accuracy versus the HPA100X2DA's ±0.06%. Both sensors measure the same pressure range (17.6 PSI), use identical RS-232 output, and share the same physical interface and operating environment specifications.

Q: Are the port connections compatible?

A: Yes. Both sensors use Female 1/8" (3.18mm) Swagelok™ threaded ports. Existing tubing and fittings designed for the HPA100X2DA connect directly to the HPA200X2DA without adapter requirements.

Q: Does the HPA200X2DA require different power supply specifications?

A: No. Both sensors operate on identical voltage supply ranges (5.5V to 30V). Existing power distribution circuits require no modification.

Q: Why is the HPA100X2DA listed as obsolete?

A: The HPA100X2DA has been superseded by the HPA200X2DA. The newer model offers improved accuracy while maintaining full backward compatibility, making it the recommended choice for new designs and replacement applications.

Q: Are there any environmental or compliance differences?

A: Both sensors operate across -40°C to 85°C and maintain MSL 1 (Unlimited) moisture sensitivity ratings. Both are RoHS non-compliant. No environmental or compliance advantages exist between the two models.

Q: What is the inventory status for these parts?

A: The HPA100X2DA (obsolete) has 743 pieces in stock. The HPA200X2DA (active) has 1107 pieces in stock, providing greater availability for ongoing procurement needs.

Request Quote (Ships tomorrow)