HER602GP-TP Equivalent & Substitute Parts

Part Overview

The HER602GP-TP is a general-purpose rectifier diode manufactured by Micro Commercial Co, rated for 100 V DC reverse voltage and 6 A average rectified current in an R-6 axial through-hole package. This component is classified as "Not For New Designs," indicating it has reached end-of-life status. Identification of equivalent and substitute parts is necessary for legacy system maintenance, repair operations, and continued production support where original components are no longer readily available or have been discontinued.

Substiute Parts

HER602GP-TP
Micro Commercial CoIn Stock: 2026HER602GP-TP Datasheet
HER602GP-TP
Current Part
6A01B-G
Comchip TechnologyIn Stock: 7766A01B-G Datasheet
6A01B-G
Similar

Key Parameters

Parameter Value Unit
Voltage - DC Reverse (Vr) (Max) 100 V
Current - Average Rectified (Io) 6 A
Voltage - Forward (Vf) (Max) @ If 1.1 V @ 6 A
Reverse Recovery Time (trr) 50 ns
Current - Reverse Leakage @ Vr 10 µA @ 100 V
Capacitance @ Vr, F 100 pF @ 4V, 1MHz
Mounting Type Through Hole
Package / Case R-6, Axial
Operating Temperature - Junction -55 to 150 °C
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the HER602GP-TP is determined by strict equivalence across the following critical electrical and mechanical parameters:

Mandatory Matching Parameters:

  • Voltage - DC Reverse (Vr) (Max): 100 V
  • Current - Average Rectified (Io): 6 A
  • Package / Case: R-6, Axial
  • Mounting Type: Through Hole

Compatible Variation Parameters:

  • Voltage - Forward (Vf) (Max) @ If: Substitute must not exceed 1.1 V @ 6 A
  • Reverse Recovery Time (trr): Substitute may operate at Standard Recovery (>500 ns) or Fast Recovery (≤500 ns)
  • Operating Temperature - Junction: Substitute must support minimum -55°C to 125°C range
  • Current - Reverse Leakage @ Vr: Substitute must not exceed 10 µA @ 100 V
  • Capacitance @ Vr, F: Substitute must not exceed 100 pF @ 4V, 1MHz

The substitute part 6A01B-G manufactured by Comchip Technology meets all mandatory matching parameters and operates within all compatible variation parameters, establishing it as a valid electrical and mechanical equivalent.

Parameter Comparison

Parameter HER602GP-TP (Micro Commercial Co) 6A01B-G (Comchip Technology) Match Status
Voltage - DC Reverse (Vr) (Max) 100 V 100 V Equivalent
Current - Average Rectified (Io) 6 A 6 A Equivalent
Voltage - Forward (Vf) (Max) @ If 1.1 V @ 6 A 1 V @ 6 A Substitute Superior
Speed Fast Recovery ≤ 500 ns, > 200 mA (Io) Standard Recovery > 500 ns, > 200 mA (Io) Different Recovery Class
Reverse Recovery Time (trr) 50 ns Not Specified Data Not Provided
Current - Reverse Leakage @ Vr 10 µA @ 100 V 10 µA @ 100 V Equivalent
Capacitance @ Vr, F 100 pF @ 4V, 1MHz 100 pF @ 4V, 1MHz Equivalent
Mounting Type Through Hole Through Hole Equivalent
Package / Case R-6, Axial R-6, Axial Equivalent
Operating Temperature - Junction -55°C ~ 150°C -55°C ~ 125°C Substitute Reduced Range
RoHS Status ROHS3 Compliant ROHS3 Compliant Equivalent
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited) Equivalent
Product Status Not For New Designs Active Substitute Active

Engineering Selection Recommendations

Primary Substitute: 6A01B-G (Comchip Technology)

The 6A01B-G is the qualified substitute for the HER602GP-TP based on electrical and mechanical equivalence. Selection of this substitute is supported by the following factors:

  1. Electrical Equivalence: Both components share identical voltage ratings (100 V DC reverse), current ratings (6 A average rectified), reverse leakage characteristics (10 µA @ 100 V), and junction capacitance (100 pF @ 4V, 1MHz).

  2. Mechanical Compatibility: Both components utilize the R-6 axial through-hole package, ensuring direct physical and electrical compatibility in existing PCB layouts and circuit designs.

  3. Compliance Status: The 6A01B-G maintains ROHS3 compliance and MSL 1 (Unlimited) rating, matching the original component's regulatory and environmental specifications.

  4. Product Status: The 6A01B-G carries Active product status, ensuring continued availability and supply chain support, whereas the HER602GP-TP is designated Not For New Designs.

  5. Forward Voltage Advantage: The 6A01B-G exhibits a lower maximum forward voltage (1 V @ 6 A) compared to the HER602GP-TP (1.1 V @ 6 A), resulting in reduced power dissipation in rectification applications.

Operational Consideration: The 6A01B-G operates at Standard Recovery speed (>500 ns), whereas the HER602GP-TP is classified as Fast Recovery (≤500 ns). This difference does not preclude substitution in general-purpose rectification applications but may affect performance in high-frequency switching circuits where fast recovery characteristics are critical to circuit operation.

Temperature Range Consideration: The 6A01B-G supports a maximum junction temperature of 125°C, compared to the HER602GP-TP maximum of 150°C. Applications requiring sustained operation above 125°C require thermal analysis to confirm compatibility.

Frequently Asked Questions (FAQ)

Q: Can the 6A01B-G directly replace the HER602GP-TP in existing designs?

A: Yes. Both components share identical voltage ratings (100 V), current ratings (6 A), and R-6 axial through-hole package specifications. Direct physical and electrical substitution is supported without PCB modification.

Q: What is the significance of the different recovery speeds (Fast vs. Standard)?

A: The HER602GP-TP operates at Fast Recovery (≤500 ns), while the 6A01B-G operates at Standard Recovery (>500 ns). In general-purpose rectification applications operating at line frequency (50/60 Hz), this difference has negligible impact. In high-frequency switching applications (>10 kHz), the slower recovery time of the 6A01B-G may increase switching losses and heat generation. Circuit performance analysis is required for applications with switching frequencies above 1 kHz.

Q: Does the lower forward voltage of the 6A01B-G provide a benefit?

A: Yes. The 6A01B-G forward voltage maximum is 1 V @ 6 A, compared to 1.1 V @ 6 A for the HER602GP-TP. This 0.1 V reduction decreases power dissipation in the diode, resulting in lower heat generation and improved circuit efficiency. This benefit is particularly significant in high-current rectification applications.

Q: Are there compliance or regulatory differences between these components?

A: No. Both components are ROHS3 compliant, carry MSL 1 (Unlimited) ratings, and are REACH unaffected. Both are classified under ECCN EAR99 and HTSUS 8541.10.0080. Regulatory and environmental compliance is equivalent.

Q: What is the maximum junction temperature difference, and does it affect substitution?

A: The HER602GP-TP supports -55°C to 150°C, while the 6A01B-G supports -55°C to 125°C. The 25°C reduction in maximum temperature does not affect most industrial and consumer applications operating below 125°C. Applications requiring sustained operation above 125°C require thermal design verification to confirm the 6A01B-G operates within specified limits.

Q: Is the 6A01B-G available in the same packaging format?

A: The 6A01B-G is supplied in Bulk packaging, whereas the HER602GP-TP is supplied in Tape & Reel (TR) format. Both components use the R-6 axial through-hole package. Bulk packaging does not affect electrical or mechanical compatibility; it reflects only the supplier's distribution format.

Q: Why is the HER602GP-TP marked "Not For New Designs"?

A: This designation indicates the component has reached end-of-life status and is no longer recommended for new product development. The 6A01B-G, carrying Active product status, is the recommended substitute for ongoing production and new design implementations.

Request Quote (Ships tomorrow)