Request Quote
(Ships tomorrow)
HAT 600-S Hall Effect Current Sensor - Equivalent & Substitute Parts
Part Overview
The HAT 600-S is an active Hall Effect open-loop current sensor manufactured by LEM USA Inc., designed for bidirectional AC/DC current measurement up to 600A. This single-channel module delivers ratiometric voltage output with ±1% linearity and accuracy across a frequency range of DC to 25kHz. The part is classified as Active product status with full RoHS compliance and REACH unaffected designation.
Substitute parts within the HAT series become necessary when application requirements specify lower current-sensing ranges, inventory constraints occur, or system design modifications reduce the maximum current threshold below 600A. All substitute models maintain identical electrical and mechanical characteristics except for current-sensing capacity.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | HAT 600-S |
| Manufacturer | LEM USA Inc. |
| Series | HAT |
| Product Status | Active |
| Sensor Type | Hall Effect, Open Loop |
| Current - Sensing | 600A |
| For Measuring | AC/DC |
| Number of Channels | 1 |
| Output Type | Ratiometric, Voltage |
| Frequency Range | DC ~ 25kHz |
| Linearity | ±1% |
| Accuracy | ±1% |
| Voltage - Supply | ±15V |
| Response Time | 5µs |
| Current - Supply (Max) | 15mA |
| Operating Temperature | -40°C ~ 105°C |
| Polarization | Bidirectional |
| Mounting Type | Chassis Mount |
| Package / Case | Module |
| Packaging | Tray |
| RoHS Status | RoHS Compliant |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 9030.33.3800 |
Substitute Part Grouping Explanation
Substitution within the HAT series is determined by current-sensing capacity. The HAT 600-S can be substituted with HAT 200-S, HAT 400-S, or HAT 500-S when the application maximum current requirement falls within the lower rating of the substitute part.
Key Parameters Governing Substitution:
- Sensor Type: Hall Effect, Open Loop (identical across all models)
- For Measuring: AC/DC (identical across all models)
- Number of Channels: 1 (identical across all models)
- Output Type: Ratiometric, Voltage (identical across all models)
- Frequency Range: DC ~ 25kHz (identical across all models)
- Linearity: ±1% (identical across all models)
- Accuracy: ±1% (identical across all models)
- Voltage - Supply: ±15V (identical across all models)
- Response Time: 5µs (identical across all models)
- Current - Supply (Max): 15mA (identical across all models)
- Operating Temperature: -40°C ~ 105°C (identical across all models)
- Polarization: Bidirectional (identical across all models)
- Mounting Type: Chassis Mount (identical across all models)
- Package / Case: Module (identical across all models)
- Packaging: Tray (identical across all models)
- RoHS Status: RoHS Compliant (identical across all models)
- REACH Status: REACH Unaffected (identical across all models)
Variable Parameter:
- Current - Sensing: 200A, 400A, 500A, or 600A
Parameter Comparison
| Parameter | HAT 600-S | HAT 500-S | HAT 400-S | HAT 200-S |
|---|---|---|---|---|
| Manufacturer Part Number | HAT 600-S | HAT 500-S | HAT 400-S | HAT 200-S |
| Manufacturer | LEM USA Inc. | LEM USA Inc. | LEM USA Inc. | LEM USA Inc. |
| Series | HAT | HAT | HAT | HAT |
| Product Status | Active | Active | Active | Active |
| Sensor Type | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop |
| Current - Sensing | 600A | 500A | 400A | 200A |
| For Measuring | AC/DC | AC/DC | AC/DC | AC/DC |
| Number of Channels | 1 | 1 | 1 | 1 |
| Output Type | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage |
| Frequency Range | DC ~ 25kHz | DC ~ 25kHz | DC ~ 25kHz | DC ~ 25kHz |
| Linearity | ±1% | ±1% | ±1% | ±1% |
| Accuracy | ±1% | ±1% | ±1% | ±1% |
| Voltage - Supply | ±15V | ±15V | ±15V | ±15V |
| Response Time | 5µs | 5µs | 5µs | 5µs |
| Current - Supply (Max) | 15mA | 15mA | 15mA | 15mA |
| Operating Temperature | -40°C ~ 105°C | -40°C ~ 105°C | -40°C ~ 105°C | -40°C ~ 105°C |
| Polarization | Bidirectional | Bidirectional | Bidirectional | Bidirectional |
| Mounting Type | Chassis Mount | Chassis Mount | Chassis Mount | Chassis Mount |
| Package / Case | Module | Module | Module | Module |
| Packaging | Tray | Tray | Tray | Tray |
| RoHS Status | RoHS Compliant | RoHS Compliant | RoHS Compliant | RoHS Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 | EAR99 | EAR99 |
| HTSUS | 9030.33.3800 | 9030.33.3800 | 9030.33.3800 | 9030.33.3800 |
Engineering Selection Recommendations
All substitute parts within the HAT series maintain Active product status with identical RoHS Compliant and REACH Unaffected certifications. Selection between HAT 600-S, HAT 500-S, HAT 400-S, and HAT 200-S is determined solely by the maximum current measurement requirement of the application.
Selection Criteria:
- HAT 600-S: Applications requiring current measurement up to 600A
- HAT 500-S: Applications requiring current measurement up to 500A
- HAT 400-S: Applications requiring current measurement up to 400A
- HAT 200-S: Applications requiring current measurement up to 200A
All models share identical electrical performance characteristics including ±1% linearity, ±1% accuracy, 5µs response time, and DC to 25kHz frequency capability. Compliance certifications and regulatory designations are uniform across the series. Component selection should be based on the maximum current threshold of the specific application circuit.
Frequently Asked Questions (FAQ)
Q: Can HAT 200-S substitute for HAT 600-S?
A: HAT 200-S is not a direct substitute for HAT 600-S. The HAT 200-S has a maximum current-sensing capacity of 200A, while HAT 600-S measures up to 600A. HAT 200-S can only be used in applications where the maximum current requirement does not exceed 200A.
Q: What is the primary difference between HAT 600-S and HAT 500-S?
A: The primary difference is current-sensing capacity. HAT 600-S measures up to 600A, while HAT 500-S measures up to 500A. All other electrical and mechanical parameters are identical.
Q: Are all HAT series models pin-compatible?
A: All HAT series models share identical mounting type (Chassis Mount), package type (Module), and packaging format (Tray). Physical compatibility is maintained across the series.
Q: Do all HAT series models have the same output characteristics?
A: Yes. All models deliver ratiometric voltage output with ±1% linearity and ±1% accuracy across the DC to 25kHz frequency range.
Q: What is the supply voltage requirement for HAT 600-S and its substitutes?
A: All HAT series models require ±15V supply voltage with maximum supply current of 15mA.
Q: Are there any temperature operating range differences between substitute models?
A: No. All HAT series models operate across the identical temperature range of -40°C to 105°C.
Q: Can HAT 600-S be used in place of HAT 500-S?
A: HAT 600-S has a higher current-sensing capacity (600A) than HAT 500-S (500A). While HAT 600-S can physically fit and electrically function in applications designed for HAT 500-S, it is not a cost-effective substitution. Component selection should match the application requirement.
Q: What is the response time for all HAT series current sensors?
A: All HAT series models have a response time of 5µs.
Q: Are all HAT series models RoHS compliant?
A: Yes. All HAT 200-S, HAT 400-S, HAT 500-S, and HAT 600-S models are RoHS Compliant with REACH Unaffected status.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts