Request Quote
(Ships tomorrow)
HAIS 200-P Hall Effect Current Sensor Equivalent & Substitute Parts
Part Overview
The HAIS 200-P is a Hall Effect open-loop bidirectional current sensor manufactured by LEM USA Inc., designed for AC/DC current measurement applications up to 200A. This component is classified as "Not For New Designs," indicating it has reached end-of-life status in the manufacturer's product portfolio. For ongoing production requirements or new system designs, equivalent substitute parts from the HAIS and HASS series provide functional alternatives with identical or enhanced electrical characteristics.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | HAIS 200-P |
| Manufacturer | LEM USA Inc. |
| Series | HAIS |
| Current Sensing Range | 200A |
| Sensor Type | Hall Effect, Open Loop |
| Polarization | Bidirectional |
| For Measuring | AC/DC |
| Number of Channels | 1 |
| Output Type | Ratiometric, Voltage |
| Frequency Range | DC ~ 50kHz |
| Linearity | ±0.5% |
| Accuracy | ±1% |
| Supply Voltage | 5V |
| Response Time | 5µs |
| Supply Current (Max) | 19mA |
| Operating Temperature Range | -40°C ~ 85°C |
| Mounting Type | Through Hole |
| Package Type | Module |
| RoHS Status | RoHS Compliant |
| REACH Status | REACH Unaffected |
| Product Status | Not For New Designs |
Substitute Part Grouping Explanation
Substitution of the HAIS 200-P is determined by the following critical parameters:
Primary Substitution Criteria:
- Sensor Type: Hall Effect, Open Loop
- Polarization: Bidirectional
- For Measuring: AC/DC
- Number of Channels: 1
- Output Type: Ratiometric, Voltage
- Supply Voltage: 5V
- Operating Temperature Range: -40°C ~ 85°C
- Mounting Type: Through Hole
- Package Type: Module
Secondary Substitution Criteria (Current Sensing Range): The HAIS 200-P operates at 200A. Substitute parts are available in lower current ratings (50A, 100A, 150A) within the same HAIS series, and in the HASS series at the same 200A rating. Selection depends on the application's actual current measurement requirement.
Substitute Parts Identified:
- HAIS 50-P / HAIS 50-TP – 50A current sensing
- HAIS 100-P / HAIS 100-TP – 100A current sensing
- HAIS 150-P – 150A current sensing
- HASS 200-S – 200A current sensing (enhanced response time)
All substitute parts maintain identical electrical specifications for linearity, accuracy, frequency response, and supply characteristics. The HASS 200-S variant offers improved response time (3µs vs. 5µs) while maintaining all other parameters.
Parameter Comparison
| Parameter | HAIS 200-P | HAIS 150-P | HAIS 100-P | HAIS 100-TP | HAIS 50-P | HAIS 50-TP | HASS 200-S |
|---|---|---|---|---|---|---|---|
| Current Sensing (A) | 200 | 150 | 100 | 100 | 50 | 50 | 200 |
| Sensor Type | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop | Hall Effect, Open Loop |
| Polarization | Bidirectional | Bidirectional | Bidirectional | Bidirectional | Bidirectional | Bidirectional | Bidirectional |
| For Measuring | AC/DC | AC/DC | AC/DC | AC/DC | AC/DC | AC/DC | AC/DC |
| Number of Channels | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| Output Type | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage | Ratiometric, Voltage |
| Frequency Range | DC ~ 50kHz | DC ~ 50kHz | DC ~ 50kHz | DC ~ 50kHz | DC ~ 50kHz | DC ~ 50kHz | DC ~ 50kHz |
| Linearity | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Accuracy | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
| Supply Voltage | 5V | 5V | 5V | 5V | 5V | 5V | 5V |
| Response Time | 5µs | 5µs | 5µs | 5µs | 5µs | 5µs | 3µs |
| Supply Current (Max) | 19mA | 19mA | 19mA | 19mA | 19mA | 19mA | 19mA |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C | -40°C ~ 85°C | -40°C ~ 85°C | -40°C ~ 85°C | -40°C ~ 85°C | -40°C ~ 85°C |
| Mounting Type | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole |
| Package Type | Module | Module | Module | Module | Module | Module | Module |
| RoHS Status | RoHS Compliant | RoHS Compliant | RoHS Compliant | RoHS Compliant | RoHS Compliant | RoHS Compliant | RoHS Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected | REACH Unaffected | REACH Unaffected | REACH Unaffected | REACH Unaffected | REACH Unaffected |
| Product Status | Not For New Designs | Not For New Designs | Not For New Designs | Not For New Designs | Not For New Designs | Not For New Designs | Not For New Designs |
Engineering Selection Recommendations
For Direct 200A Replacement: The HASS 200-S is the primary substitute for the HAIS 200-P when maintaining the 200A current sensing specification. Both parts are RoHS Compliant and REACH Unaffected. The HASS 200-S provides superior response time (3µs versus 5µs), making it suitable for applications requiring faster transient detection. Both parts are classified as "Not For New Designs," indicating manufacturer end-of-life status.
For Lower Current Applications: If the application's actual current measurement requirement is below 200A, the HAIS series offers scaled alternatives:
- HAIS 150-P for applications up to 150A
- HAIS 100-P or HAIS 100-TP for applications up to 100A
- HAIS 50-P or HAIS 50-TP for applications up to 50A
All variants maintain identical electrical performance specifications (linearity ±0.5%, accuracy ±1%, frequency response DC ~ 50kHz) and environmental compliance.
Packaging Variants: The HAIS 100-P and HAIS 100-TP, as well as HAIS 50-P and HAIS 50-TP, represent packaging variants of the same electrical specification. Selection between -P and -TP designations depends on specific procurement and inventory requirements.
Compliance Considerations: All substitute parts maintain RoHS Compliance and REACH Unaffected status, ensuring regulatory alignment with the original HAIS 200-P specification.
Frequently Asked Questions (FAQ)
Q: Can HAIS 100-P be used as a substitute for HAIS 200-P?
A: The HAIS 100-P is electrically compatible with the HAIS 200-P in terms of sensor type, output characteristics, supply voltage, and operating temperature. However, it has a maximum current sensing range of 100A versus 200A. Substitution is valid only if the application's actual current measurement requirement does not exceed 100A. All other electrical parameters (linearity, accuracy, frequency response, response time) are identical.
Q: What is the difference between HAIS 100-P and HAIS 100-TP?
A: Both HAIS 100-P and HAIS 100-TP are 100A Hall Effect current sensors with identical electrical specifications. The designation difference (-P versus -TP) relates to packaging configuration. Selection between these variants depends on procurement availability and specific board-level integration requirements.
Q: Is HASS 200-S a direct replacement for HAIS 200-P?
A: The HASS 200-S is a functional equivalent for the HAIS 200-P at the 200A current sensing level. Both maintain identical specifications for linearity (±0.5%), accuracy (±1%), frequency response (DC ~ 50kHz), supply voltage (5V), and operating temperature (-40°C ~ 85°C). The HASS 200-S offers improved response time (3µs versus 5µs), which may provide performance benefits in applications requiring faster transient detection.
Q: Are all substitute parts RoHS Compliant?
A: Yes. All substitute parts listed (HAIS 50-P, HAIS 50-TP, HAIS 100-P, HAIS 100-TP, HAIS 150-P, and HASS 200-S) are RoHS Compliant and REACH Unaffected, matching the compliance status of the HAIS 200-P.
Q: Why is the HAIS 200-P marked "Not For New Designs"?
A: This designation indicates the part has reached end-of-life status in the manufacturer's product portfolio. For new system designs or ongoing production, equivalent substitute parts from the HAIS and HASS series provide current alternatives with maintained or enhanced electrical performance.
Q: What determines whether a substitute part is compatible?
A: Compatibility is determined by matching the following parameters: sensor type (Hall Effect, Open Loop), polarization (Bidirectional), measurement type (AC/DC), number of channels (1), output type (Ratiometric, Voltage), supply voltage (5V), operating temperature range (-40°C ~ 85°C), mounting type (Through Hole), and package type (Module). The current sensing range must meet or exceed the application requirement. All listed substitutes satisfy these criteria.
Q: Can HAIS 50-P be used in a 200A application?
A: No. The HAIS 50-P has a maximum current sensing range of 50A. Using it in a 200A application would exceed its rated specification and result in measurement error or component failure. Substitute selection must match or exceed the application's actual current measurement requirement.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts