Request Quote
(Ships tomorrow)
FN3258-7-45 Equivalent & Substitute Parts
Part Overview
The FN3258-7-45 is a three-phase delta EMC/EMI line filter rated for 7 A with chassis mount configuration and terminal block termination. This component is classified as obsolete, making identification of active equivalent parts essential for ongoing system support and procurement planning. The substitute part FN3258-7-44 provides functional equivalence while maintaining active product status.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Filter Type | Three Phase (Delta) |
| Configuration | Single Stage |
| Current Rating | 7 A |
| Voltage - Phase to Ground/Neutral | 277 V AC |
| Voltage - Phase to Phase | 480 V AC |
| Frequency Range | DC ~ 60Hz |
| Mounting Type | Chassis Mount |
| Termination Style | Terminal Block |
| Operating Temperature | -25°C ~ 100°C |
| Approval Agencies | CSA, ENEC, UR |
Substitute Part Grouping Explanation
The FN3258-7-44 qualifies as a direct substitute for the FN3258-7-45 based on the following critical parameters:
- Three-phase delta filter topology with identical single-stage configuration
- Matching current rating of 7 A
- Identical voltage specifications: 277 V phase-to-ground/neutral and 480 V phase-to-phase
- Identical frequency operating range: DC ~ 60Hz
- Matching mechanical interface: chassis mount with terminal block termination
- Equivalent operating temperature range: -25°C ~ 100°C
- Identical regulatory approvals: CSA, ENEC, UR certifications
Both parts belong to the FN 3258 series and share the same functional design. The primary distinction is product status and packaging configuration.
Parameter Comparison
| Parameter | FN3258-7-45 | FN3258-7-44 | Compatibility |
|---|---|---|---|
| Filter Type | Three Phase (Delta) | Three Phase (Delta) | Identical |
| Configuration | Single Stage | Single Stage | Identical |
| Current Rating | 7 A | 7 A | Identical |
| Voltage - Phase to Ground/Neutral | 277 V AC | 277 V AC | Identical |
| Voltage - Phase to Phase | 480 V AC | 480 V AC | Identical |
| Frequency Range | DC ~ 60Hz | DC ~ 60Hz | Identical |
| Mounting Type | Chassis Mount | Chassis Mount | Identical |
| Termination Style | Terminal Block | Terminal Block | Identical |
| Operating Temperature | -25°C ~ 100°C | -25°C ~ 100°C | Identical |
| Approval Agencies | CSA, ENEC, UR | CSA, ENEC, UR | Identical |
| Product Status | Obsolete | Active | Substitute is active |
| RoHS Status | RoHS Compliant | ROHS3 Compliant | Both compliant |
| Packaging | Not specified | Tray | Tray packaging available |
Engineering Selection Recommendations
The FN3258-7-44 is the appropriate selection for applications currently specified with FN3258-7-45. Both parts maintain identical electrical and mechanical specifications across all critical parameters. The FN3258-7-44 offers the advantage of active product status, ensuring continued availability and supply chain support. Both parts carry equivalent regulatory certifications (CSA, ENEC, UR) and comply with RoHS requirements. The FN3258-7-44 is available in tray packaging with confirmed inventory of 1000 units.
Frequently Asked Questions (FAQ)
Q: Can FN3258-7-44 directly replace FN3258-7-45 in existing designs?
A: Yes. Both parts are identical in electrical specifications (7 A, 277 V phase-to-ground, 480 V phase-to-phase), filter topology (three-phase delta, single stage), mechanical interface (chassis mount, terminal block), and regulatory approvals (CSA, ENEC, UR).
Q: What is the difference between these two part numbers?
A: The primary difference is product status. FN3258-7-45 is obsolete, while FN3258-7-44 is active. FN3258-7-44 is supplied in tray packaging. All functional and electrical parameters are identical.
Q: Are there any compliance differences?
A: Both parts are RoHS compliant and REACH unaffected. FN3258-7-44 carries ROHS3 compliance designation, representing current RoHS standards. Both maintain identical regulatory agency approvals.
Q: What packaging is available for the substitute part?
A: FN3258-7-44 is supplied in tray packaging with 1000 units currently in stock.
Q: Are there any temperature or frequency limitations when substituting?
A: No. Both parts operate identically across the full temperature range (-25°C ~ 100°C) and frequency range (DC ~ 60Hz).
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts