FN3258-7-45 Equivalent & Substitute Parts

Part Overview

The FN3258-7-45 is a three-phase delta EMC/EMI line filter rated for 7 A with chassis mount configuration and terminal block termination. This component is classified as obsolete, making identification of active equivalent parts essential for ongoing system support and procurement planning. The substitute part FN3258-7-44 provides functional equivalence while maintaining active product status.

Substiute Parts

FN3258-7-45
Schaffner EMC Inc.In Stock: 907FN3258-7-45 Datasheet
FN3258-7-45
Current Part
FN3258-7-44
Schaffner EMC Inc.In Stock: 1097FN3258-7-44 Datasheet
FN3258-7-44
Similar

Key Parameters

Parameter Value
Filter Type Three Phase (Delta)
Configuration Single Stage
Current Rating 7 A
Voltage - Phase to Ground/Neutral 277 V AC
Voltage - Phase to Phase 480 V AC
Frequency Range DC ~ 60Hz
Mounting Type Chassis Mount
Termination Style Terminal Block
Operating Temperature -25°C ~ 100°C
Approval Agencies CSA, ENEC, UR

Substitute Part Grouping Explanation

The FN3258-7-44 qualifies as a direct substitute for the FN3258-7-45 based on the following critical parameters:

  • Three-phase delta filter topology with identical single-stage configuration
  • Matching current rating of 7 A
  • Identical voltage specifications: 277 V phase-to-ground/neutral and 480 V phase-to-phase
  • Identical frequency operating range: DC ~ 60Hz
  • Matching mechanical interface: chassis mount with terminal block termination
  • Equivalent operating temperature range: -25°C ~ 100°C
  • Identical regulatory approvals: CSA, ENEC, UR certifications

Both parts belong to the FN 3258 series and share the same functional design. The primary distinction is product status and packaging configuration.

Parameter Comparison

Parameter FN3258-7-45 FN3258-7-44 Compatibility
Filter Type Three Phase (Delta) Three Phase (Delta) Identical
Configuration Single Stage Single Stage Identical
Current Rating 7 A 7 A Identical
Voltage - Phase to Ground/Neutral 277 V AC 277 V AC Identical
Voltage - Phase to Phase 480 V AC 480 V AC Identical
Frequency Range DC ~ 60Hz DC ~ 60Hz Identical
Mounting Type Chassis Mount Chassis Mount Identical
Termination Style Terminal Block Terminal Block Identical
Operating Temperature -25°C ~ 100°C -25°C ~ 100°C Identical
Approval Agencies CSA, ENEC, UR CSA, ENEC, UR Identical
Product Status Obsolete Active Substitute is active
RoHS Status RoHS Compliant ROHS3 Compliant Both compliant
Packaging Not specified Tray Tray packaging available

Engineering Selection Recommendations

The FN3258-7-44 is the appropriate selection for applications currently specified with FN3258-7-45. Both parts maintain identical electrical and mechanical specifications across all critical parameters. The FN3258-7-44 offers the advantage of active product status, ensuring continued availability and supply chain support. Both parts carry equivalent regulatory certifications (CSA, ENEC, UR) and comply with RoHS requirements. The FN3258-7-44 is available in tray packaging with confirmed inventory of 1000 units.

Frequently Asked Questions (FAQ)

Q: Can FN3258-7-44 directly replace FN3258-7-45 in existing designs?

A: Yes. Both parts are identical in electrical specifications (7 A, 277 V phase-to-ground, 480 V phase-to-phase), filter topology (three-phase delta, single stage), mechanical interface (chassis mount, terminal block), and regulatory approvals (CSA, ENEC, UR).

Q: What is the difference between these two part numbers?

A: The primary difference is product status. FN3258-7-45 is obsolete, while FN3258-7-44 is active. FN3258-7-44 is supplied in tray packaging. All functional and electrical parameters are identical.

Q: Are there any compliance differences?

A: Both parts are RoHS compliant and REACH unaffected. FN3258-7-44 carries ROHS3 compliance designation, representing current RoHS standards. Both maintain identical regulatory agency approvals.

Q: What packaging is available for the substitute part?

A: FN3258-7-44 is supplied in tray packaging with 1000 units currently in stock.

Q: Are there any temperature or frequency limitations when substituting?

A: No. Both parts operate identically across the full temperature range (-25°C ~ 100°C) and frequency range (DC ~ 60Hz).

Request Quote (Ships tomorrow)