Request Quote
(Ships tomorrow)
ECG.00.302.CLL Equivalent & Substitute Parts
Part Overview
The ECG.00.302.CLL is a 2-position circular connector receptacle manufactured by LEMO, featuring female sockets with solder cup termination. This component is classified as a panel-mount, push-pull fastening connector with shielded construction and gold-plated mating contacts. The part maintains Active product status and is RoHS3 compliant.
Substitute parts are identified when equivalent electrical and mechanical parameters align with the main part's specifications, enabling direct functional replacement in applications where the connector footprint and performance characteristics remain compatible.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Connector Type | Receptacle, Female Sockets |
| Number of Positions | 2 |
| Termination | Solder Cup |
| Fastening Type | Push-Pull |
| Mounting Type | Panel Mount |
| Shell Material | Brass |
| Shell Finish | Chrome |
| Contact Finish - Mating | Gold |
| Ingress Protection | IP50 - Dust Protected |
| Current Rating | 5A |
| Operating Temperature | -55°C ~ 250°C |
| Insert Material | Polyetheretherketone (PEEK) |
| RoHS Status | ROHS3 Compliant |
| Shielding | Shielded |
Substitute Part Grouping Explanation
The substitute part G5CL0C-P02LCC0-0000 (ODU MINI-SNAP® L series) is identified as functionally equivalent based on the following alignment of critical parameters:
- Connector type: Both are receptacle, female socket configurations
- Position count: Both feature 2-position designs
- Termination method: Both utilize solder cup termination
- Fastening mechanism: Both employ push-pull fastening
- Mounting configuration: Both are panel-mount designs
- Shell material: Both use brass construction
- Contact finish: Both feature gold-plated mating surfaces
- Ingress protection: Both meet IP50 dust protection rating
- Insert material: Both use PEEK insulation
- Compliance: Both are RoHS3 compliant and REACH unaffected
Substitution is valid where these core electrical and mechanical parameters are required. Differences in shell finish specification, current rating tolerance, and operating temperature range must be evaluated against specific application requirements.
Parameter Comparison
| Parameter | ECG.00.302.CLL (LEMO) | G5CL0C-P02LCC0-0000 (ODU) |
|---|---|---|
| Manufacturer | LEMO | ODU |
| Series | 00B | ODU MINI-SNAP® L |
| Connector Type | Receptacle, Female Sockets | Receptacle, Female Sockets |
| Number of Positions | 2 | 2 |
| Termination | Solder Cup | Solder Cup |
| Fastening Type | Push-Pull | Push-Pull |
| Mounting Type | Panel Mount | Panel Mount |
| Mounting Feature | Front and Rear Side Nut | Bulkhead - Front or Rear Side Nut |
| Shell Material | Brass | Brass |
| Shell Finish | Chrome | Chrome over Nickel |
| Contact Finish - Mating | Gold | Gold |
| Color | Silver | Silver |
| Ingress Protection | IP50 - Dust Protected | IP50 - Dust Protected |
| Current Rating (Amps) | 5A | 4A |
| Operating Temperature | -55°C ~ 250°C | -40°C ~ 120°C |
| Insert Material | Polyetheretherketone (PEEK) | Polyetheretherketone (PEEK) |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8536.69.4020 | 8536.69.4020 |
Engineering Selection Recommendations
Both the ECG.00.302.CLL and G5CL0C-P02LCC0-0000 maintain Active product status and satisfy RoHS3 and REACH compliance requirements. Selection between these parts depends on application-specific constraints:
The ECG.00.302.CLL supports a 5A current rating and extended operating temperature range of -55°C to 250°C, making it suitable for high-temperature or high-current applications. The G5CL0C-P02LCC0-0000 operates within -40°C to 120°C with a 4A current rating, appropriate for standard industrial, medical, military, and testing equipment applications within these thermal and electrical boundaries.
Both connectors feature identical core mechanical and electrical compatibility parameters: 2-position configuration, solder cup termination, push-pull fastening, panel-mount design, brass shell with gold-plated contacts, IP50 ingress protection, and PEEK insulation. Shell finish differs slightly (chrome versus chrome over nickel), which does not affect functional substitution in standard applications.
Frequently Asked Questions (FAQ)
Q: Can G5CL0C-P02LCC0-0000 directly replace ECG.00.302.CLL in all applications?
A: Direct substitution is valid where the application operates within -40°C to 120°C and requires maximum 4A current. If the application demands the extended temperature range (-55°C to 250°C) or 5A current rating of the ECG.00.302.CLL, the substitute part is not suitable.
Q: What are the key compatibility parameters for these connectors?
A: Both connectors share identical specifications for connector type (receptacle, female sockets), position count (2), termination method (solder cup), fastening mechanism (push-pull), mounting configuration (panel mount), shell material (brass), contact finish (gold), ingress protection (IP50), and insert material (PEEK).
Q: How do the current ratings differ between these parts?
A: The ECG.00.302.CLL is rated for 5A, while the G5CL0C-P02LCC0-0000 is rated for 4A. Applications requiring currents between 4A and 5A must use the ECG.00.302.CLL.
Q: Are there differences in operating temperature ranges?
A: Yes. The ECG.00.302.CLL operates from -55°C to 250°C, while the G5CL0C-P02LCC0-0000 operates from -40°C to 120°C. High-temperature applications below -40°C or above 120°C require the ECG.00.302.CLL.
Q: Do both connectors meet the same compliance standards?
A: Both parts are RoHS3 compliant, REACH unaffected, classified as EAR99, and share the same HTSUS code (8536.69.4020). Compliance requirements are equivalent.
Q: What is the difference in shell finish between these connectors?
A: The ECG.00.302.CLL features chrome finish, while the G5CL0C-P02LCC0-0000 features chrome over nickel finish. Both provide equivalent corrosion protection for standard applications.
Q: Are the mounting features identical?
A: Both connectors are panel-mount designs with side nut fastening. The ECG.00.302.CLL specifies front and rear side nut mounting, while the G5CL0C-P02LCC0-0000 specifies bulkhead front or rear side nut mounting. Both configurations support equivalent panel installation.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts