Request Quote
(Ships tomorrow)
DP150-GY Terminal Block Connector Equivalent & Substitute Parts
Part Overview
The DP150-GY is a 2-position feed-through terminal block connector manufactured by Eaton - Bussmann Electrical Division, part of the Magnum® DP series. This component is designed for electrical connections handling wire gauges from 1/0 to 12 AWG with a rated current capacity of 150 A at both IEC and UL standards. The product is currently classified as obsolete, making identification of functionally equivalent alternatives essential for system maintenance, repair, and component sourcing.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | DP150-GY |
| Manufacturer | Eaton - Bussmann Electrical Division |
| Category | Terminal Blocks |
| Type | Feed Through |
| Number of Positions | 2 |
| Number of Levels | 1 |
| Terminal Width | 16.0 mm |
| Termination Style | Screw |
| Current Rating - IEC | 150 A |
| Voltage Rating - IEC | 1000 V |
| Current Rating - UL | 150 A |
| Voltage Rating - UL | 600 V |
| Wire Gauge Range - AWG | 1/0-12 AWG |
| Wire Gauge Range - mm² | 2.5-50 mm² |
| Color | Gray |
| Insulation Material | Polyamide (PA66), Nylon 6/6 |
| Flammability Rating | UL94 V-0 |
| Stripping Length | 12 mm |
| Moisture Sensitivity Level | 1 (Unlimited) |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution eligibility for the DP150-GY is determined by the following critical parameters that must remain consistent or compatible:
- Electrical Performance: Current rating (150 A minimum), voltage rating (1000 V IEC / 600 V UL minimum)
- Physical Configuration: 2-position, 1-level feed-through design with 16.0 mm terminal width
- Termination Method: Screw-type termination
- Wire Compatibility: Support for wire gauges within or overlapping the 1/0-12 AWG range
- Material & Safety: Polyamide insulation with UL94 V-0 flammability rating
- Mechanical Fit: Compatible connector body dimensions and mounting interface
The Phoenix Contact 3047727 (CLIPLINE UT series) meets these substitution criteria while maintaining electrical and mechanical compatibility with the DP150-GY.
Parameter Comparison
| Parameter | DP150-GY (Eaton) | 3047727 (Phoenix Contact) | Compatibility Notes |
|---|---|---|---|
| Type | Feed Through | Feed Through | Identical |
| Number of Positions | 2 | 2 | Identical |
| Number of Levels | 1 | 1 | Identical |
| Terminal Width | 16.0 mm | 16.0 mm | Identical |
| Termination Style | Screw | Screw | Identical |
| Current Rating - IEC | 150 A | 150 A | Identical |
| Voltage Rating - IEC | 1000 V | 1000 V | Identical |
| Current Rating - UL | 150 A | 150 A | Identical |
| Voltage Rating - UL | 600 V | 600 V | Identical |
| Wire Gauge Range - AWG | 1/0-12 AWG | 1/0-14 AWG | 3047727 supports extended range to 14 AWG |
| Wire Gauge Range - mm² | 2.5-50 mm² | 1.5-50 mm² | 3047727 supports extended range to 1.5 mm² |
| Color | Gray | Gray | Identical |
| Insulation Material | Polyamide (PA66), Nylon 6/6 | Polyamide (PA), Nylon | Both polyamide-based, compatible |
| Flammability Rating | UL94 V-0 | UL94 V-0 | Identical |
| Stripping Length | 12 mm | 18 mm | 3047727 requires 6 mm additional stripping |
| Product Status | Obsolete | Active | 3047727 is currently in production |
| RoHS Status | Not specified | ROHS3 Compliant | 3047727 meets current environmental standards |
Engineering Selection Recommendations
The Phoenix Contact 3047727 is a direct functional equivalent to the obsolete DP150-GY. Both components share identical electrical ratings (150 A / 1000 V IEC, 150 A / 600 V UL), physical configuration (2-position, 16.0 mm terminal width), and safety certifications (UL94 V-0). The 3047727 is currently in active production status, ensuring long-term availability and supply chain continuity.
Key considerations for selection:
- Wire Gauge Compatibility: The 3047727 supports an extended wire gauge range (1/0-14 AWG vs. 1/0-12 AWG), providing broader application flexibility while maintaining full compatibility with the original DP150-GY specification range.
- Stripping Length Difference: The 3047727 requires 18 mm wire stripping versus 12 mm for the DP150-GY. Installation procedures must account for this 6 mm difference.
- Environmental Compliance: The 3047727 carries ROHS3 compliance and REACH unaffected status, meeting current regulatory requirements for new equipment designs and replacements.
- Supply Availability: With 1099 units in stock versus 796 units of the obsolete DP150-GY, the 3047727 offers superior availability for immediate deployment.
Frequently Asked Questions (FAQ)
Q: Can the Phoenix Contact 3047727 be used as a direct replacement for the DP150-GY in existing installations?
A: Yes. Both components meet identical electrical specifications (150 A current, 1000 V IEC voltage rating) and share the same 2-position, feed-through configuration with 16.0 mm terminal width and screw termination. Physical mounting and electrical performance are compatible.
Q: What is the significance of the different wire gauge ranges (1/0-12 AWG vs. 1/0-14 AWG)?
A: The DP150-GY accepts wire gauges from 1/0 to 12 AWG (2.5-50 mm²). The 3047727 extends this range to 14 AWG (1.5-50 mm²), meaning it can accommodate smaller gauge wires. For applications using only 1/0-12 AWG wire, both components are fully compatible. The extended range of the 3047727 provides additional flexibility for future applications.
Q: Why does the 3047727 require 18 mm stripping length instead of 12 mm?
A: Stripping length is determined by the internal terminal design and contact geometry. The 3047727 requires 6 mm additional stripping to ensure proper wire seating and electrical contact. Installation procedures must be adjusted accordingly when transitioning from DP150-GY to 3047727.
Q: Are there any compliance or certification differences between these components?
A: Both components carry UL94 V-0 flammability ratings and meet electrical safety standards. The 3047727 additionally carries ROHS3 compliance and REACH unaffected status, making it suitable for applications subject to current environmental regulations. The DP150-GY compliance status is not specified in available documentation.
Q: What is the packaging difference between these components?
A: The DP150-GY is supplied in standard packaging (not specified). The 3047727 is supplied in bulk packaging, which may affect ordering quantities and logistics considerations.
Q: Is the 3047727 suitable for both IEC and UL applications?
A: Yes. The 3047727 meets both IEC standards (150 A / 1000 V) and UL standards (150 A / 600 V), identical to the DP150-GY. It is suitable for applications requiring either certification standard.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts