Request Quote
(Ships tomorrow)
Omron D4GL-2BFA-A Interlock Solenoid Release Equivalent & Substitute Parts
Part Overview
The Omron D4GL-2BFA-A is a DPST interlock solenoid release switch designed for panel disconnect applications. This component features a 24VDC supply voltage, 240VAC current rating at 750mA, and a holding force of 102kgf. The part carries obsolete product status, making equivalent substitute parts necessary for ongoing system maintenance and new installations where this functionality is required.
Substiute Parts
Key Parameters
| Parameter | D4GL-2BFA-A |
|---|---|
| Manufacturer | Omron Automation and Safety |
| Series | D4GL |
| Product Status | Obsolete |
| Type | Solenoid Release |
| Circuit Configuration | DPST-NO/NC + DPST-NC |
| Current Rating (AC) | 750mA |
| Voltage Rating | 240VAC |
| Supply Voltage | 24VDC |
| Holding Force | 102kgf |
| Actuator Type | Panel Disconnect |
| Termination Style | Screw Terminal |
| Conduit Thread Size | G1/2 |
| Operating Temperature | -10°C ~ 55°C |
| Ingress Protection | IP67 |
| Approval Agencies | CE, cULus, TUV |
| Moisture Sensitivity Level | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution for the D4GL-2BFA-A is based on the following critical parameters that must align for functional equivalence:
Mandatory Matching Parameters:
- Manufacturer: Omron Automation and Safety
- Type: Solenoid Release
- Circuit Configuration: DPST-NO/NC + DPST-NC
- Actuator Type: Panel Disconnect
- Conduit Thread Size: G1/2
- Operating Temperature Range: -10°C ~ 55°C
- Ingress Protection: IP67
- Moisture Sensitivity Level: 1 (Unlimited)
Allowable Variation Parameters:
- Current Rating: Substitute parts may have different AC/DC current ratings provided they meet or exceed the application requirements
- Voltage Rating: Substitute parts may operate at different voltage levels (120VAC/125VDC vs. 240VAC/24VDC) depending on system design
- Holding Force: Substitute parts may have different holding force values (6kgf vs. 102kgf) based on application load requirements
- Termination Style: Screw Terminal or Connector options are both acceptable
- Product Status: Active status substitutes are preferred for obsolete parts
The D4SL-N series parts meet all mandatory matching parameters and are classified as active products, making them suitable substitutes for the obsolete D4GL-2BFA-A.
Parameter Comparison
| Parameter | D4GL-2BFA-A | D4SL-N2BFA | D4SL-N2BFA-N |
|---|---|---|---|
| Manufacturer | Omron Automation and Safety | Omron Automation and Safety | Omron Automation and Safety |
| Product Status | Obsolete | Active | Active |
| Type | Solenoid Release | Solenoid Release | Solenoid Release |
| Circuit Configuration | DPST-NO/NC + DPST-NC | DPST-NO/NC + DPST-NC | DPST-NO/NC + DPST-NC |
| Current Rating (AC) | 750mA | 1.5A | 1.5A |
| Current Rating (DC) | — | 220mA | 220mA |
| Voltage Rating | 240VAC | 120VAC, 125VDC | 120VAC, 125VDC |
| Holding Force | 102kgf | 6kgf | 6kgf |
| Actuator Type | Panel Disconnect | Panel Disconnect | Panel Disconnect |
| Termination Style | Screw Terminal | Screw Terminal | Connector |
| Conduit Thread Size | G1/2 | G1/2 | G1/2 |
| Operating Temperature | -10°C ~ 55°C | -10°C ~ 55°C | -10°C ~ 55°C |
| Ingress Protection | IP67 | IP67 | IP67 |
| Approval Agencies | CE, cULus, TUV | CCC, CE, cURus, TUV | CCC, CE, cURus, TUV |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
D4SL-N2BFA (Screw Terminal Configuration)
This substitute is suitable for applications requiring screw terminal connections. Both the D4GL-2BFA-A and D4SL-N2BFA maintain identical termination style, simplifying installation in existing harnesses. The D4SL-N2BFA carries active product status with expanded approval certifications (CCC, CE, cURus, TUV), providing superior long-term availability and support compared to the obsolete D4GL-2BFA-A.
D4SL-N2BFA-N (Connector Configuration)
This substitute is appropriate for applications where connector-based termination is preferred or required. The connector interface offers advantages in modularity and field replacement scenarios. Like the D4SL-N2BFA, this part maintains active product status and expanded regulatory approvals.
Voltage and Current Considerations
The D4SL-N series operates at 120VAC/125VDC with current ratings of 1.5A (AC) and 220mA (DC), differing from the D4GL-2BFA-A specifications of 240VAC at 750mA. System design must accommodate these electrical parameter differences. The D4SL-N series provides higher AC current capacity (1.5A vs. 750mA), making it suitable for applications with increased current demands.
Holding Force Difference
The D4SL-N series provides 6kgf holding force compared to the D4GL-2BFA-A at 102kgf. Applications requiring the higher holding force of the original part may require mechanical redesign or alternative component selection.
Frequently Asked Questions (FAQ)
Q: Can D4SL-N2BFA or D4SL-N2BFA-N directly replace D4GL-2BFA-A without modification?
A: Direct replacement requires verification of system voltage and current requirements. The D4SL-N series operates at different voltage levels (120VAC/125VDC) and current ratings (1.5A AC, 220mA DC) than the original part (240VAC, 750mA). Additionally, the holding force differs significantly (6kgf vs. 102kgf). System design must accommodate these parameter differences.
Q: What is the primary difference between D4SL-N2BFA and D4SL-N2BFA-N?
A: The primary difference is termination style. D4SL-N2BFA uses screw terminals, while D4SL-N2BFA-N uses a connector interface. All other electrical and mechanical parameters are identical. Selection depends on installation requirements and existing harness configuration.
Q: Why is the D4GL-2BFA-A obsolete?
A: Product obsolescence is determined by the manufacturer. The D4SL-N series represents the current active equivalent from Omron Automation and Safety for this solenoid release function.
Q: Are the approval certifications compatible between D4GL-2BFA-A and D4SL-N substitutes?
A: The D4GL-2BFA-A carries CE, cULus, and TUV certifications. The D4SL-N series carries CCC, CE, cURus, and TUV certifications. The D4SL-N series provides expanded regulatory coverage, including CCC certification not present on the original part.
Q: What is the holding force difference, and does it affect substitution?
A: The D4GL-2BFA-A provides 102kgf holding force, while D4SL-N series provides 6kgf. This significant difference means applications dependent on the higher holding force require evaluation of mechanical load requirements and potential system redesign.
Q: Are both substitute parts in stock?
A: Yes. D4SL-N2BFA inventory: 790 Pcs. D4SL-N2BFA-N inventory: 1005 Pcs. Both are available as new original stock.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts