SCHURTER 4435.0185 Circuit Breaker Thermal 20A 240VAC 60VDC Equivalent & Substitute Parts

Part Overview

The SCHURTER 4435.0185 is an active thermal circuit breaker rated for 20A at 240V AC and 60V DC, featuring a rocker actuator and panel mount configuration in the TA35 series. This component is designed for overcurrent protection in AC and DC applications requiring dual-voltage operation. Substitute parts are necessary when the TA35 series becomes unavailable or when design requirements call for alternative series variants that maintain identical electrical and mechanical specifications.

Substiute Parts

4435.0185
SCHURTER Inc.In Stock: 11984435.0185 Datasheet
4435.0185
Current Part
4430.0035
SCHURTER Inc.In Stock: 6914430.0035 Datasheet
4430.0035
Parametric Equivalent
4430.0038
SCHURTER Inc.In Stock: 7624430.0038 Datasheet
4430.0038
Parametric Equivalent
4430.0572
SCHURTER Inc.In Stock: 10424430.0572 Datasheet
4430.0572
Parametric Equivalent
4430.0978
SCHURTER Inc.In Stock: 10804430.0978 Datasheet
4430.0978
Parametric Equivalent
4430.0988
SCHURTER Inc.In Stock: 11864430.0988 Datasheet
4430.0988
Parametric Equivalent
4430.1067
SCHURTER Inc.In Stock: 9774430.1067 Datasheet
4430.1067
Parametric Equivalent
4430.1068
SCHURTER Inc.In Stock: 10104430.1068 Datasheet
4430.1068
Parametric Equivalent
4430.161
SCHURTER Inc.In Stock: 8284430.161 Datasheet
4430.161
Parametric Equivalent
4430.1629
SCHURTER Inc.In Stock: 11494430.1629 Datasheet
4430.1629
Parametric Equivalent
4430.1789
SCHURTER Inc.In Stock: 11304430.1789 Datasheet
4430.1789
Parametric Equivalent
4430.1805
SCHURTER Inc.In Stock: 9504430.1805 Datasheet
4430.1805
Parametric Equivalent
4430.1894
SCHURTER Inc.In Stock: 11244430.1894 Datasheet
4430.1894
Parametric Equivalent
4430.2115
SCHURTER Inc.In Stock: 15904430.2115 Datasheet
4430.2115
Parametric Equivalent
4430.2196
SCHURTER Inc.In Stock: 40654430.2196 Datasheet
4430.2196
Parametric Equivalent
4430.23
SCHURTER Inc.In Stock: 12774430.23 Datasheet
4430.23
Parametric Equivalent
4430.2306
SCHURTER Inc.In Stock: 9044430.2306 Datasheet
4430.2306
Parametric Equivalent
4430.2554
SCHURTER Inc.In Stock: 11274430.2554 Datasheet
4430.2554
Parametric Equivalent
4430.256
SCHURTER Inc.In Stock: 8104430.256 Datasheet
4430.256
Parametric Equivalent
4430.2793
SCHURTER Inc.In Stock: 9234430.2793 Datasheet
4430.2793
Parametric Equivalent
4430.2802
SCHURTER Inc.In Stock: 7954430.2802 Datasheet
4430.2802
Parametric Equivalent
4430.2856
SCHURTER Inc.In Stock: 10414430.2856 Datasheet
4430.2856
Parametric Equivalent
4430.2979
SCHURTER Inc.In Stock: 10274430.2979 Datasheet
4430.2979
Parametric Equivalent
4430.3292
SCHURTER Inc.In Stock: 8884430.3292 Datasheet
4430.3292
Parametric Equivalent
4430.3395
SCHURTER Inc.In Stock: 8844430.3395 Datasheet
4430.3395
Parametric Equivalent
4430.3426
SCHURTER Inc.In Stock: 9774430.3426 Datasheet
4430.3426
Parametric Equivalent
4430.3634
SCHURTER Inc.In Stock: 8304430.3634 Datasheet
4430.3634
Parametric Equivalent
4430.3823
SCHURTER Inc.In Stock: 7934430.3823 Datasheet
4430.3823
Parametric Equivalent
4435.0002
SCHURTER Inc.In Stock: 8264435.0002 Datasheet
4435.0002
Parametric Equivalent
4435.0013
SCHURTER Inc.In Stock: 49494435.0013 Datasheet
4435.0013
Parametric Equivalent
4435.0121
SCHURTER Inc.In Stock: 12094435.0121 Datasheet
4435.0121
Parametric Equivalent
4435.0151
SCHURTER Inc.In Stock: 9544435.0151 Datasheet
4435.0151
Parametric Equivalent
4435.0225
SCHURTER Inc.In Stock: 10524435.0225 Datasheet
4435.0225
Parametric Equivalent
4435.027
SCHURTER Inc.In Stock: 10164435.027 Datasheet
4435.027
Parametric Equivalent
4435.0308
SCHURTER Inc.In Stock: 7924435.0308 Datasheet
4435.0308
Parametric Equivalent
4435.0321
SCHURTER Inc.In Stock: 14204435.0321 Datasheet
4435.0321
Parametric Equivalent

Key Parameters

Parameter Specification
Manufacturer Part Number 4435.0185
Manufacturer SCHURTER Inc.
Series TA35
Breaker Type Thermal
Current Rating 20A
Voltage Rating - AC 240V
Voltage Rating - DC 60V
Mounting Type Panel Mount
Actuator Type Rocker
Number of Poles 2
Product Status Active
RoHS Status ROHS3 Compliant
REACH Status REACH Unaffected
Packaging Bulk

Substitute Part Grouping Explanation

Substitution eligibility for the SCHURTER 4435.0185 is determined by strict equivalence across the following critical parameters:

  • Current Rating: 20A (exact match required)
  • Voltage Rating - AC: 240V (exact match required)
  • Voltage Rating - DC: 60V (exact match required)
  • Breaker Type: Thermal (exact match required)
  • Mounting Type: Panel Mount (exact match required)
  • Actuator Type: Rocker (exact match required)
  • Number of Poles: 2 (exact match required)
  • RoHS Status: ROHS3 Compliant (minimum requirement)
  • REACH Status: REACH Unaffected (minimum requirement)

All substitute parts listed below meet these criteria. Series designation (TA35 vs. TA45) does not restrict substitution when all electrical and mechanical parameters are identical. Substitute parts are grouped by series variant and availability status.

Parameter Comparison

Part Number Series Current Rating Voltage AC Voltage DC Breaker Type Mounting Actuator Poles RoHS Inventory (Pcs)
4435.0185 TA35 20A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 1114
4430.0035 TA45 20A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 673
4430.0038 TA45 20A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 688
4430.0572 TA45 20A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 951
4430.0978 TA45 20A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 1070
4430.0988 TA45 20A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 1097
4430.1067 TA45 20A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 922
4430.1068 TA45 20A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 916
4430.161 TA45 20A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 753
4430.1629 TA45 20A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 1098
4430.1789 TA45 20A 240V 60V Thermal Panel Mount Rocker 2 ROHS3 1031

Engineering Selection Recommendations

All listed substitute parts maintain active product status and ROHS3 compliance. Selection between the main part (4435.0185, TA35 series) and substitute parts (TA45 series variants) should be based on availability and design documentation requirements.

Parts 4430.0572, 4430.1067, 4430.1068, and 4430.161 include documented approval agency certifications: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. These certifications are provided in the component data and may be relevant for applications requiring specific regulatory compliance documentation.

Moisture Sensitivity Level (MSL) is listed as either Not Applicable or Vendor Undefined across all parts, indicating no special moisture handling requirements for storage or handling.

Frequently Asked Questions (FAQ)

Q: Can I substitute 4430.0035 for 4435.0185 in my application?

A: Yes. Both parts are electrically and mechanically equivalent with identical current ratings (20A), voltage ratings (240V AC / 60V DC), breaker type (thermal), mounting configuration (panel mount rocker), and pole count (2). The series designation change from TA35 to TA45 does not affect substitution eligibility when all specified parameters match.

Q: What is the difference between TA35 and TA45 series parts?

A: Based on provided data, both series share identical electrical specifications and mechanical configurations for this 20A 240VAC 60VDC application. Series designation alone does not determine substitution compatibility; all critical parameters must match.

Q: Do any substitute parts have additional certifications?

A: Parts 4430.0572, 4430.1067, 4430.1068, and 4430.161 include approval agency certifications for CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Other parts do not list these certifications in the provided data.

Q: Are all substitute parts ROHS3 compliant?

A: Yes. All listed substitute parts are ROHS3 compliant and REACH unaffected, matching the compliance status of the main part 4435.0185.

Q: Which substitute part has the highest inventory availability?

A: Part 4430.0988 has the highest inventory with 1097 pieces in stock, followed by 4430.1629 with 1098 pieces. The main part 4435.0185 has 1114 pieces available.

Q: Can I use these parts interchangeably in existing designs?

A: Yes, provided your design documentation specifies only the electrical and mechanical parameters listed in this reference. If your design specifies a particular series (TA35 or TA45) or requires specific approval certifications, verify compatibility before substitution.

Request Quote (Ships tomorrow)