The SCHURTER 4430.2152 is a thermal circuit breaker rated for 10A at 240V AC and 60V DC, featuring a rocker actuator and panel mount configuration in the TA45 series. This component is classified as Active product status and is ROHS3 compliant. Equivalent and substitute parts are identified based on matching electrical ratings, mechanical mounting specifications, and functional characteristics to ensure direct interchangeability in circuit protection applications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 4430.2152 |
| Manufacturer | SCHURTER Inc. |
| Series | TA45 |
| Breaker Type | Thermal |
| Current Rating | 10A |
| Voltage Rating - AC | 240V |
| Voltage Rating - DC | 60V |
| Mounting Type | Panel Mount |
| Actuator Type | Rocker |
| Number of Poles | 2 |
| Product Status | Active |
| RoHS Status | ROHS3 Compliant |
| REACH Status | REACH Unaffected |
Substitute Part Grouping Explanation
Substitute parts for the SCHURTER 4430.2152 are qualified based on the following critical parameters that determine functional interchangeability:
- Current Rating: 10A (exact match required)
- Voltage Rating - AC: 240V (exact match required)
- Voltage Rating - DC: 60V (exact match required)
- Breaker Type: Thermal (exact match required)
- Mounting Type: Panel Mount (exact match required)
- Actuator Type: Rocker (exact match required)
- Number of Poles: 2 (exact match required)
- Series: TA45 (exact match required)
- Manufacturer: SCHURTER Inc. (same manufacturer)
- Product Status: Active (current production status)
All identified substitute parts meet these electrical and mechanical specifications, ensuring direct replacement capability in existing circuit protection designs.
Parameter Comparison
| Part Number | Current Rating | Voltage AC | Voltage DC | Breaker Type | Mounting Type | Actuator Type | Poles | Series | Product Status | RoHS Status | Inventory (Pcs) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4430.2152 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1074 |
| 4430.0022 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 890 |
| 4430.0413 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1180 |
| 4430.047 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1088 |
| 4430.0778 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1193 |
| 4430.0861 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1086 |
| 4430.0963 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1145 |
| 4430.1038 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 940 |
| 4430.1477 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1123 |
| 4430.1849 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 826 |
| 4430.1892 | 10A | 240V | 60V | Thermal | Panel Mount | Rocker | 2 | TA45 | Active | ROHS3 | 1268 |
Engineering Selection Recommendations
All substitute parts listed are manufactured by SCHURTER Inc. and maintain Active product status, ensuring continued availability and support. Parts with documented approval agencies (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077) provide additional regulatory compliance documentation where specified. Selection among equivalent parts should be based on inventory availability and specific regulatory requirements for the target application. All parts are ROHS3 compliant and REACH unaffected, meeting current environmental and regulatory standards.
Frequently Asked Questions (FAQ)
Q: Can any of these substitute parts replace the 4430.2152 directly?
A: Yes. All listed substitute parts match the critical electrical parameters (10A, 240V AC, 60V DC), breaker type (thermal), mounting configuration (panel mount rocker), and pole count (2-pole). They are functionally equivalent for circuit protection applications.
Q: What determines if a part is a valid substitute?
A: Substitution is based on exact matching of current rating, AC and DC voltage ratings, breaker type, mounting type, actuator type, number of poles, and series designation. All substitute parts meet these criteria.
Q: Are there differences in regulatory approvals among the substitute parts?
A: Some substitute parts include documented approval agencies (CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077), while others do not list specific approvals in the provided data. Verify approval requirements for your specific application before selection.
Q: What is the difference between parts with and without listed approval agencies?
A: Parts with listed approval agencies have documented compliance certifications. Parts without listed approvals in this data may still meet regulatory requirements; consult manufacturer documentation for complete certification details.
Q: Are all substitute parts in active production?
A: Yes. All substitute parts maintain Active product status, indicating current manufacturing and availability.
Q: How do I select among multiple equivalent parts?
A: Selection can be based on inventory availability, specific regulatory certifications required for your application, and any documented approval agencies. All parts are electrically and mechanically equivalent.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts