SCHURTER 4430.071 Thermal Circuit Breaker 16A 240VAC 60VDC Equivalent & Substitute Parts

Part Overview

The SCHURTER 4430.071 is a thermal circuit breaker rated for 16A at 240V AC and 60V DC, featuring a rocker panel mount actuator with dual-pole configuration. This component is classified as Active product status and is ROHS3 compliant. Equivalent and substitute parts within the TA45 series maintain identical electrical and mechanical specifications, enabling direct replacement in applications requiring thermal overcurrent protection in industrial control and power distribution systems.

Substiute Parts

4430.071
SCHURTER Inc.In Stock: 10234430.071 Datasheet
4430.071
Current Part
4430.0034
SCHURTER Inc.In Stock: 9204430.0034 Datasheet
4430.0034
Parametric Equivalent
4430.0699
SCHURTER Inc.In Stock: 10334430.0699 Datasheet
4430.0699
Parametric Equivalent
4430.0904
SCHURTER Inc.In Stock: 9674430.0904 Datasheet
4430.0904
Parametric Equivalent
4430.1296
SCHURTER Inc.In Stock: 12294430.1296 Datasheet
4430.1296
Parametric Equivalent
4430.1563
SCHURTER Inc.In Stock: 9414430.1563 Datasheet
4430.1563
Parametric Equivalent
4430.1729
SCHURTER Inc.In Stock: 10664430.1729 Datasheet
4430.1729
Parametric Equivalent
4430.2105
SCHURTER Inc.In Stock: 8174430.2105 Datasheet
4430.2105
Parametric Equivalent
4430.2145
SCHURTER Inc.In Stock: 7034430.2145 Datasheet
4430.2145
Parametric Equivalent
4430.2374
SCHURTER Inc.In Stock: 10654430.2374 Datasheet
4430.2374
Parametric Equivalent
4430.2496
SCHURTER Inc.In Stock: 8434430.2496 Datasheet
4430.2496
Parametric Equivalent
4430.2626
SCHURTER Inc.In Stock: 10454430.2626 Datasheet
4430.2626
Parametric Equivalent
4435.0093
SCHURTER Inc.In Stock: 11434435.0093 Datasheet
4435.0093
Parametric Equivalent
4435.0224
SCHURTER Inc.In Stock: 11654435.0224 Datasheet
4435.0224
Parametric Equivalent
4435.0271
SCHURTER Inc.In Stock: 10654435.0271 Datasheet
4435.0271
Parametric Equivalent
4435.0378
SCHURTER Inc.In Stock: 11864435.0378 Datasheet
4435.0378
Parametric Equivalent

Key Parameters

Parameter Specification
Manufacturer SCHURTER Inc.
Series TA45
Breaker Type Thermal
Current Rating 16A
Voltage Rating - AC 240V
Voltage Rating - DC 60V
Mounting Type Panel Mount
Actuator Type Rocker
Number of Poles 2
Product Status Active
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution within this product family is determined by strict equivalence across the following parameters: current rating (16A), voltage ratings (240V AC / 60V DC), breaker type (thermal), mounting configuration (panel mount rocker), pole count (2-pole), and series designation (TA45). All substitute parts listed maintain identical electrical performance characteristics and mechanical form factor, enabling interchangeable use in existing circuit protection applications. Substitution is valid only when all specified parameters match the original component.

Parameter Comparison

Part Number Manufacturer Series Current Rating Voltage AC Voltage DC Breaker Type Mounting Poles Actuator RoHS Status Inventory (Pcs)
4430.071 SCHURTER Inc. TA45 16A 240V 60V Thermal Panel Mount 2 Rocker ROHS3 917
4430.0034 SCHURTER Inc. TA45 16A 240V 60V Thermal Panel Mount 2 Rocker ROHS3 882
4430.0699 SCHURTER Inc. TA45 16A 240V 60V Thermal Panel Mount 2 Rocker ROHS3 969
4430.0904 SCHURTER Inc. TA45 16A 240V 60V Thermal Panel Mount 2 Rocker ROHS3 922
4430.1296 SCHURTER Inc. TA45 16A 240V 60V Thermal Panel Mount 2 Rocker ROHS3 1130
4430.1563 SCHURTER Inc. TA45 16A 240V 60V Thermal Panel Mount 2 Rocker ROHS3 848
4430.1729 SCHURTER Inc. TA45 16A 240V 60V Thermal Panel Mount 2 Rocker ROHS3 1052
4430.2105 SCHURTER Inc. TA45 16A 240V 60V Thermal Panel Mount 2 Rocker ROHS3 771
4430.2145 SCHURTER Inc. TA45 16A 240V 60V Thermal Panel Mount 2 Rocker ROHS3 676
4430.2374 SCHURTER Inc. TA45 16A 240V 60V Thermal Panel Mount 2 Rocker ROHS3 982
4430.2496 SCHURTER Inc. TA45 16A 240V 60V Thermal Panel Mount 2 Rocker ROHS3 762

Engineering Selection Recommendations

All listed substitute parts are classified as Active product status and maintain ROHS3 compliance. Parts 4430.071, 4430.1563, 4430.1729, 4430.2145, 4430.2374, and 4430.2496 carry full approval agency certifications including CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077. Parts 4430.0034, 4430.0699, 4430.0904, 4430.1296, and 4430.2105 maintain ROHS3 compliance and REACH unaffected status. Selection among equivalent parts may be based on inventory availability and certification requirements specific to the application jurisdiction.

Frequently Asked Questions (FAQ)

Q: Can all listed part numbers be used interchangeably with SCHURTER 4430.071?

A: Yes. All substitute parts maintain identical electrical ratings (16A, 240V AC, 60V DC), breaker type (thermal), mounting configuration (panel mount rocker), and pole count (2-pole) within the TA45 series. Direct substitution is valid for applications requiring these specifications.

Q: What determines whether a part is a valid substitute?

A: Substitution validity is determined by matching current rating, AC/DC voltage ratings, breaker type, mounting type, actuator type, pole count, and series designation. All listed parts meet these criteria for the 4430.071.

Q: Are there differences in approval certifications among the substitute parts?

A: Parts 4430.071, 4430.1563, 4430.1729, 4430.2145, 4430.2374, and 4430.2496 include CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, and UL1077 certifications. Parts 4430.0034, 4430.0699, 4430.0904, 4430.1296, and 4430.2105 do not list these specific certifications in available documentation. Certification requirements should be verified against application standards.

Q: What is the inventory status of substitute parts?

A: Current inventory ranges from 676 to 1130 pieces across all substitute part numbers. Part 4430.1296 has the highest availability at 1130 pieces, while 4430.2145 has the lowest at 676 pieces.

Q: Can I substitute a part with different voltage or current ratings?

A: No. Substitution is valid only when all electrical parameters match exactly. Parts with different voltage ratings or current ratings are not equivalent and cannot be used as substitutes.

Request Quote (Ships tomorrow)