Request Quote
(Ships tomorrow)
Phoenix Contact 3041969 Terminal Block Equivalent & Substitute Parts
Part Overview
The Phoenix Contact 3041969 is an 8-position terminal block plug connection designed for DIN rail mounting with 5.2mm terminal width and spring push-in termination. This component operates at 10A (IEC) / 250V (IEC) and accommodates wire gauges from 12-28 AWG (0.08-4mm²). The part is classified as Last Time Buy, indicating discontinued production status. Identifying equivalent and substitute parts is necessary to ensure continued availability for maintenance, repair, and new installations where this specific configuration is required.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 3041969 |
| Manufacturer | Phoenix Contact |
| Category | Terminal Blocks |
| Type | Plug Connection |
| Mounting Type | DIN Rail |
| Number of Positions | 8 |
| Terminal Width | 5.2mm |
| Termination Style | Plug Receptacles, Push In, Spring |
| Current Rating (IEC) | 10 A |
| Voltage Rating (IEC) | 250 V |
| Wire Gauge Range (AWG) | 12-28 AWG |
| Wire Gauge Range (mm²) | 0.08-4mm² |
| Housing Color | Gray |
| Material - Insulation | Polyamide (PA), Nylon |
| Flammability Rating | UL94 V-0 |
| RoHS Status | RoHS Compliant |
Substitute Part Grouping Explanation
Substitution of the Phoenix Contact 3041969 is determined by the following critical parameters that must remain compatible:
Mandatory Compatibility Parameters:
- Terminal width: 5.2mm (ensures mechanical fit with mating connectors)
- Termination style: Plug Receptacles, Push In, Spring (functional equivalence)
- Mounting type: DIN Rail (installation compatibility)
- Current rating: Minimum 10A IEC (electrical capacity)
- Voltage rating: Minimum 250V IEC (electrical capacity)
- Housing color: Gray (visual and connector interface standardization)
- Material insulation: Polyamide (PA), Nylon (material compatibility)
- Flammability rating: UL94 V-0 (safety compliance)
- RoHS compliance: Required (regulatory requirement)
Flexible Parameters (may differ):
- Number of positions (can be higher if application permits)
- Wire gauge range (can be broader)
- Length and height (physical space permitting)
- Series designation (different product lines within manufacturer)
The substitute part 3012316 maintains all mandatory compatibility parameters while offering expanded position count (12 vs. 8) and broader wire gauge accommodation (12-26 AWG vs. 12-28 AWG).
Parameter Comparison
| Parameter | 3041969 (Main Part) | 3012316 (Substitute) |
|---|---|---|
| Manufacturer | Phoenix Contact | Phoenix Contact |
| Category | Terminal Blocks | Terminal Blocks |
| Type | Plug Connection | Plug Connection |
| Mounting Type | DIN Rail | DIN Rail |
| Number of Positions | 8 | 12 |
| Number of Levels | 4 | 4 |
| Terminal Width | 5.2mm | 5.2mm |
| Termination Style | Plug Receptacles, Push In, Spring | Plug Receptacles, Push In, Spring |
| Current Rating (IEC) | 10 A | 10 A |
| Voltage Rating (IEC) | 250 V | 250 V |
| Wire Gauge Range (AWG) | 12-28 AWG | 12-26 AWG |
| Wire Gauge Range (mm²) | 0.08-4mm² | 0.14-4mm² |
| Housing Color | Gray | Gray |
| Material - Insulation | Polyamide (PA), Nylon | Polyamide (PA), Nylon |
| Flammability Rating | UL94 V-0 | UL94 V-0 |
| RoHS Status | RoHS Compliant | RoHS Compliant |
| Product Status | Last Time Buy | Active |
Engineering Selection Recommendations
The Phoenix Contact 3012316 is a direct functional substitute for the 3041969 based on electrical and mechanical compatibility. Both components share identical current and voltage ratings (10A IEC / 250V IEC), terminal width (5.2mm), termination methodology (spring push-in), and safety certifications (UL94 V-0, RoHS compliant).
The primary difference is position count: the 3012316 provides 12 positions versus 8 positions in the 3041969. This expanded capacity does not compromise compatibility with existing mating connectors or DIN rail installations, provided the physical space allocation permits the increased length (125.00mm vs. 100.99mm).
The 3012316 holds Active product status, ensuring continued availability and supply chain stability, whereas the 3041969 is designated Last Time Buy. For new designs or long-term production requirements, the 3012316 is the recommended selection.
Wire gauge accommodation differs slightly: the 3041969 supports 12-28 AWG while the 3012316 supports 12-26 AWG. Applications utilizing 27-28 AWG conductors must retain the 3041969 or identify alternative solutions.
Frequently Asked Questions (FAQ)
Q: Can the 3012316 directly replace the 3041969 in existing installations?
A: Yes, provided the installation has sufficient physical space for the increased length (125.00mm vs. 100.99mm) and the application does not require all 8 positions to be populated. The 5.2mm terminal width, spring push-in termination, and electrical ratings are identical, ensuring mechanical and electrical compatibility with existing mating connectors and DIN rail systems.
Q: What is the significance of the position count difference?
A: The 3041969 provides 8 positions while the 3012316 provides 12 positions. If an application requires exactly 8 connections, the 3012316 can accommodate this requirement with 4 unused positions. Unused positions do not affect electrical performance or safety compliance.
Q: Are there wire gauge limitations when substituting?
A: The 3041969 accommodates 12-28 AWG (0.08-4mm²) while the 3012316 accommodates 12-26 AWG (0.14-4mm²). Applications requiring 27-28 AWG conductor support must use the 3041969. For standard applications using 12-26 AWG, both parts are equivalent.
Q: What is the product status difference and why does it matter?
A: The 3041969 is Last Time Buy (discontinued), while the 3012316 is Active (current production). For new designs, maintenance stock, or long-term supply requirements, the 3012316 ensures continued availability and eliminates obsolescence risk.
Q: Are both parts RoHS compliant and UL94 V-0 rated?
A: Yes. Both the 3041969 and 3012316 are RoHS compliant and carry UL94 V-0 flammability ratings, meeting regulatory and safety requirements for industrial terminal block applications.
Q: What is the stripping length difference?
A: The 3041969 specifies 10mm stripping length, while the 3012316 specifies 8mm ~ 10mm. This minor variation does not affect substitution compatibility, as both ranges accommodate standard wire preparation practices.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts