Phoenix Contact 1826296 Terminal Block Plug - Equivalent & Substitute Parts
Part Overview
The Phoenix Contact 1826296 is a 3-position terminal block plug with female sockets, 0.200" (5.08mm) pitch, and 225° free-hanging wire entry orientation. This component is designed for screw-based electrical connections in industrial control and distribution applications. The part is currently active in production with 852 units in stock. Alternative equivalent parts may be required due to lead time constraints, regional availability, or specific application requirements where wire entry angle or electrical ratings differ from the original specification.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | 1826296 |
| Manufacturer | Phoenix Contact |
| Category | Terminal Blocks |
| Type | Plug, Female Sockets |
| Number of Positions | 3 |
| Pitch | 0.200" (5.08mm) |
| Plug Wire Entry | 225° |
| Termination Style | Screw - Rising Cage Clamp |
| Mounting Type | Free Hanging (In-Line) |
| Current - UL | 15 A |
| Voltage - UL | 300 V |
| Wire Gauge Range - AWG | 12-30 AWG |
| Wire Gauge Range - mm² | 0.2-2.5mm² |
| Screw Size | M3 |
| Material Flammability Rating | UL94 V-0 |
| RoHS Status | ROHS3 Compliant |
| Product Status | Active |
Substitute Part Grouping Explanation
Substitution eligibility for the Phoenix Contact 1826296 is determined by the following critical parameters:
Core Compatibility Requirements:
- Number of positions: 3
- Pitch: 0.200" (5.08mm)
- Type: Plug with female sockets
- Termination style: Screw - Rising Cage Clamp
- Mounting type: Free Hanging (In-Line)
- Screw size: M3
- Material flammability rating: UL94 V-0
- RoHS compliance: ROHS3 Compliant
Allowable Variations:
- Plug wire entry angle: 225° (main part) to 180° (substitute)
- Current rating: 15 A UL (both parts meet or exceed this requirement)
- Voltage rating: 300 V UL (both parts meet or exceed this requirement)
- Wire gauge range: 12-30 AWG (both parts support this range)
- Housing material: Polyamide (PA) or Polyamide (PA66) variants acceptable
- Contact mating finish: Tin (both parts)
The TE Connectivity AMP Connectors 796634-3 qualifies as a substitute based on matching all core compatibility requirements. The primary difference is the wire entry angle (180° versus 225°), which affects the physical installation orientation but does not impact electrical performance or mechanical interface compatibility.
Parameter Comparison
| Parameter | Phoenix Contact 1826296 | TE Connectivity 796634-3 |
|---|---|---|
| Manufacturer Part Number | 1826296 | 796634-3 |
| Manufacturer | Phoenix Contact | TE Connectivity AMP Connectors |
| Type | Plug, Female Sockets | Plug, Female Sockets |
| Number of Positions | 3 | 3 |
| Pitch | 0.200" (5.08mm) | 0.200" (5.08mm) |
| Plug Wire Entry | 225° | 180° |
| Termination Style | Screw - Rising Cage Clamp | Screw - Rising Cage Clamp |
| Mounting Type | Free Hanging (In-Line) | Free Hanging (In-Line) |
| Current - UL | 15 A | 15 A |
| Voltage - UL | 300 V | 300 V |
| Wire Gauge Range - AWG | 12-30 AWG | 12-30 AWG |
| Wire Gauge Range - mm² | 0.2-2.5mm² | 0.05-3mm² |
| Screw Size | M3 | M3 |
| Contact Mating Finish | Tin | Tin |
| Material Flammability Rating | UL94 V-0 | UL94 V-0 |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Product Status | Active | Active |
Engineering Selection Recommendations
Both the Phoenix Contact 1826296 and TE Connectivity 796634-3 are active production components with ROHS3 compliance and UL94 V-0 flammability ratings. Selection between these parts should be based on the following factors:
Phoenix Contact 1826296: Select this part when the 225° wire entry angle is required for the specific installation geometry or when Phoenix Contact series standardization is mandated by design specifications.
TE Connectivity 796634-3: This part is suitable as a substitute when the 180° wire entry angle is compatible with the application layout. The TE Connectivity part offers higher inventory availability (7685 units in stock versus 852 units) and supports an extended wire gauge range (0.05-3mm² versus 0.2-2.5mm²). Both parts meet identical electrical performance requirements at 15 A / 300 V UL ratings.
The choice between these components does not affect electrical performance, safety compliance, or mechanical interface compatibility with mating connectors. The decision is driven by physical installation constraints and supply chain considerations.
Frequently Asked Questions (FAQ)
Q: Can the TE Connectivity 796634-3 be used as a direct replacement for the Phoenix Contact 1826296?
A: Yes, provided the 180° wire entry angle is compatible with your installation. Both parts have identical electrical ratings (15 A / 300 V), matching pitch (5.08mm), identical screw termination (M3), and equivalent safety certifications (UL94 V-0, ROHS3). The primary difference is wire entry orientation, which is a mechanical consideration rather than an electrical one.
Q: What is the significance of the wire entry angle difference (225° versus 180°)?
A: Wire entry angle determines the physical direction from which wires approach the connector. A 225° angle provides a specific installation orientation, while 180° offers a different approach angle. The choice depends on your PCB layout, cable routing, and space constraints. Both angles are standard in industrial terminal block applications.
Q: Are there any compatibility issues with the housing material differences?
A: No. Both parts use polyamide (PA) or polyamide (PA66) nylon materials with identical UL94 V-0 flammability ratings. These material variants are functionally equivalent for this application category.
Q: Does the extended wire gauge range of the TE Connectivity part (0.05-3mm²) provide additional capability?
A: The TE Connectivity part supports a broader wire gauge range, but both parts accommodate the standard 12-30 AWG range. If your application requires wire gauges outside the Phoenix Contact specification (below 0.2mm² or above 2.5mm²), the TE Connectivity part offers additional flexibility.
Q: Are both parts suitable for the same operating temperature range?
A: The Phoenix Contact 1826296 does not specify an operating temperature range in the provided data. The TE Connectivity 796634-3 operates from -40°C to 110°C. For applications requiring temperature specification, verify the Phoenix Contact part's thermal limits with the manufacturer.
Q: What is the inventory status for each part?
A: Phoenix Contact 1826296 has 852 units in stock. TE Connectivity 796634-3 has 7685 units in stock. The TE Connectivity part offers significantly higher availability for immediate procurement.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts